Schneider Electric TAC Vista Catalog

Product Catalogue
Revision 1.1 (August 2004)
System Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
System Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
TAC Vista IV – Software Modules . . . . . . . . . . . . . . . . . . . . . . . . . .11
TAC Engineering Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
Freely Programmable Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Application Specific Controllers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Network Infrastructure Products . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Valves Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
Valves
Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .109
Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .123
Product Catalogue • Revision 1.1 • August 2004
1
Sydney
Perth
Melbourne
Brisbane
Darwin
TAC Asia Pacific Branches
Adelaide
Canberra
Shanghai
Singapore
Hong Kong
Beijing
Product Catalogue • Revision 1.1 • August 2004
3
System Overview
Providing solutions enabled by Open Systems for Building IT
®
Byblos Bank, Lebanon
Product Catalogue • Revision 1.1 • August 2004
4
TAC Vista®interoperable open systems create seamless integration
To satisfy the accelerating building control requirements of todays building owners and occupants, the controls industry focuses on information technology for building management – Building IT. By merging communications, data collection, information sharing and networking into a single, interoperable system, TAC Vista creates efficient, economical building control solutions that fit seamlessly with other products based on open system architecture. Combining industry-standard technology with an easy-to-use interface, TAC Vista produces an integrated building management solution that is reliable, flexible and cost-effective. Full integra­tion of environmental control as well as facility and energy management in a single software package allow you to customize TAC Vista for any building management application.
Open system for open choice
TAC Vista is based on totally open architecture, which gives customers freedom of choice in selecting products from a wide range of suppliers, yielding true vendor independence. TAC Vistas operating system is Microsoft
®
Windows®2000/XP/2003 Serven with standard LAN communication on Ethernet®or fiber optics using TCP/IP and standard network equipment. Field bus communication features the open LonWorks
®
technology, which is used by more than 3,000 vendors worldwide.
TCP/IP offers a variety of networking architecture options
Using TCP/IP, TAC Vista Workstations can communicate across the Internet and existing commercial WAN/LANs.
TAC Vista’s flexible architecture makes it highly scalable
TAC Vista is eminently suited for any building management application, regardless of the building size, the number of buildings or how many miles separate the buildings. TAC Vista manages multi-campus office parks and district-wide school systems just as efficiently as single, small office buildings.
National Physical Laboratory, United Kingdom
Product Catalogue • Revision 1.1 • August 2004
5
You will always know what is happening within your control system
Alarms and historical logs provide system monitoring that is both reliable and flexible. TAC Vista operators can respond to critical alarms in seconds. The receipt of an alarm can even automatically display a specific system page, giving the operator quick, graphical access to the situation. Alarm can also be sent as e-mail and SMS text messages.
TAC Vista
TAC Vista is the software solution that efficiently controls, checks and analyzes the daily operation and economical running of a building. TAC Vista is available in a variety of packages designed to maximize efficiency and economy. TAC Vista is also modular, making it easy to expand the system as your needs change.
TAC Vista Server and Workstation
TAC Vista Server provides access to the environmental controls for operator workstations. TAC Vista Workstation and is the primary operator interface to the control system. It displays daily operations through a graphical user interface, providing operators with ready access to alarms, historical logs and sophisticated data trend logs as well as standard and custom reports.
TAC Vista Webstation
Webstation allows access to the control system using common web browsers. The browser has access to the Navigator, a Microsoft®-Explorer like application, as well as to TAC Vista Graphics, Alarms and Trend Viewer. TAC Webstation provides access to trace events in the system, and periodic or automatic reports.
TAC Vista ScreenMate
The main task of the TAC Vista ScreenMate is to replace the functionality found in sophisticated room thermostats. ScreenMate makes it possible for users to read and make personal changes to settings such as the room temperature setpoint or to view the outside air temperature directly from the user’s PC. ScreenMate can be installed on every PC. It communicates with the TAC Vista Server via TCP/IP.
Monitor all aspects of how your building operates
Analyze to improve building performance
Control your environment
from your desktop
Product Catalogue • Revision 1.1 • August 2004
6
TAC Menta
®
TAC Menta is the programming software tool for the TAC Xenta®controllers. You will save time and improve operational reliability with this engineering tool for HVAC applications. TAC Menta:
Provides many pre-programmed function blocks and basic application elements Monitors offline simulations and online testing with an integrated trend log
TAC Xenta
®
All TAC Xenta controllers provide open, future­proof system architecture. TAC Xenta controllers provide access to a standardized LonWorks®­based network technology supporting a flexible control system to which components from other manufacturers can be connected.
The
TAC Xenta 100 line consists of LonMark®- certified Application Specific controllers designed for specific applications such as fan coil, VAV, chilled ceiling and rooftop air handling units.
The
TAC Xenta 280 and 300 series of LonMark-certified programmable controllers are intended for any type of plant room control applications.
The LonMark-certified
TAC Xenta 401
programmable controller is intended for larger applications.
TAC Xenta 400 I/O Modules can be added to TAC Xenta 300 and TAC Xenta 401 Controllers.
The
TAC Xenta 511 Webserver is a cost-effective method of monitoring small-scale LonWorks-based networks. The TAC Xenta 511 works like any web server, making it easy to monitor and control operations over the Internet or intranet.
The
TAC Xenta 911 is an Ethernet communication device that lets you communicate with your LonWorks network over TCP/IP.
The
TAC Xenta 913 is a cost effective solution for integrating products from different manufacturers with different protocols, e.g. BACNET & MODBUS.
The
TAC Xenta 527 is a cost effective gateway for web enabling an existing I/NET installation. It can also communicate with LonWorks networks.
Product Catalogue • Revision 1.1 • August 2004
7
System Architecture
Local System Remote System LAN/WAN System
Product Catalogue • Revision 1.1 • August 2004
8
1. Local System
Product Catalogue • Revision 1.1 • August 2004
9
3. LAN/WAN System
2. Remote System
Product Catalogue • Revision 1.1 • August 2004
10
Product Catalogue • Revision 1.1 • August 2004
11
TAC Vista®IV Software Modules
Edith Cowan University, Australia
Product Catalogue • Revision 1.1 • August 2004
12
15
TAC Vista®IV
13
Product Catalogue • Revision 1.1 • August 2004
TAC Vista IV Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
TAC Vista IV LE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
TAC Vista IV Workstation Standard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-19
TAC Vista IV Workstation Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
TAC Vista IV Workstation Professional . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
TAC Vista IV Webstation Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
TAC Vista IV ScreenMate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
TAC Vista IV OPC Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
TAC Vista OPC Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
LNS Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
TAC Vista IV Report Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
TAC Vista IV Colour Graph Editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
TAC Menta . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
TAC Vista IV OPCTool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
TAC XBuilder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
TAC Vista IV Database Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
TAC Vista IV WebTool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
TAC Vista IV Signature. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
TAC Vista IV Communication SYSTEM 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
TAC Vista IV CIPCL Editor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
TAC Vista IV IPCL Editor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Product Catalogue • Revision 1.1 • August 2004
14
17
TAC Vista®IV
15
Product Catalogue • Revision 1.1 • August 2004
TAC Vista Presentation System
TAC Vista is a graphics-based building management system for the Microsoft®Windows®2000/XP Professional/2003 Server operating system that can display, monitor and operate all technical building service systems. The TAC Vista’s modular software structure makes it flexible and adaptable with respect to system size and functionality. It is therefore suitable for buildings of all types and sizes.
TAC Vista has an open interface that supports all building service systems including HVAC technology, fire alarm, access control and lighting control, as well as complete maintenance and repair programs and facility management solutions.
Communication with the TAC Xenta
®
Controllers is via the open standard LonTalk® protocol. TAC Vista also supports stand-alone operation using the TAC Xenta Application Specific controllers and other LonWorks based devices. Modules are available that allow controllers to communicate with the older systems like TAC ZONE II and SYSTEM 7.
The OPC (OLE for Process Control) and DDE (Dynamic Data Exchange) open interfaces can be supplied with a wide range of drivers that allow third party system operation.
The number of units that can communicate with each other via the client server architecture, in a distributed system, is unlimited. The TCP/IP protocol is used for communication via a LAN/WAN (Local/Wide Area Network), which is supported in an Ethernet environment by Microsoft
®
Windows®2000/XP Professional/
2003 Server.
TAC Vista®– System Architecture example
1 1 5
3
4
1
1
M
E
D
O
M
M
5
M
E
D
O
TAC Vista®IV
1816
Product Catalogue • Revision 1.1 • August 2004
TAC Vista IV
Basic functions
Graphics-based operating interface Alarm Handling Authority/Security Trend Logging Event Viewer (system journal) Scheduling Data Protection
Options
Report Generator OPC Server, OPC Client TAC Menta
®
Color Graphics Editor Web Server Virtual room unit, ScreenMate Communication SYSTEM 7 Database Generator IPCL Editor, CIPCL Editor TAC Signature, Energy Management
Minimum Hardware
Industry standard PC with 733 MHz Pentium®III or higher processor 128 MB main memory Minimum of 300 MB available hard disk space CD ROM drive Graphics card, min. 1024 x 768 pixels Minimum 17" color monitor Microsoft®compatible mouse
Software requirements
Microsoft Windows®2000 Professional (Service pack 4), Microsoft Windows 2000 Server (Service pack 4), Microsoft Windows XP Professional (Service pack) 2003 Server, Microsoft Windows 2003 Server Microsoft Office 2000 Microsoft Internet Explorer
19
TAC Vista®IV
17
Product Catalogue • Revision 1.1 • August 2004
TAC Vista IV Server
The TAC Vista IV Server communicates with TAC Xenta controllers or with any LonWorks product using SNVTs (Standard Network Variable Types).
Connection for remote monitoring and/or remote control of TAC systems is by a LonTalk adapter or a dedicated/dial-up line. Geographically remote systems can be connected via a modem or via intranet or internet. Automatic bi-directional dial-up (Auto Dial) is used for requests, changing values and for transferring alarms.
Data storage kernel for the following functions
T A C V i s t a I V S e r v e r C D L P T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7945-0
T A C V i s t a I V S e r v e r C D U S B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7946-0
Network management in a multistation system Database Management Alarm Handling Authority/Security Backup
Scheduling Trend Logging Event Logging Central IPCL System Administration
TAC Vista IV LE (Light Edition)
The TAC Vista IV LE can communicate with TAC Xenta controllers or with any LonWorks products using SNVTs (Standard Network Variable Types).
A PC LonTalk adapter or a dedicated/dial-up line connection is used to communicate with the controllers. Geographically remote systems can be connected via a modem. Automatic bi-directional dial-up (Auto Dial) is used for requests, changing values and for transferring alarms. The TAC Vista IV LE is a single user system and cannot be expanded to include functions such as TAC Vista IV Webstation, TAC Vista IV ScreenMate or multi user systems.
TAC Vista IV LE includes TAC Vista IV Server and TAC Vista IV Workstation.
Data storage kernel for the following functions
T A C V i s t a I V L E C D L P T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7940-0
TAC Vista IV LE CD USB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7941-0
Database Management Alarm Handling Authority/Security Backup Scheduling
Trend Logging Event Logging Central IPCL System Administration
TAC Vista®IV
2018
Product Catalogue • Revision 1.1 • August 2004
TAC Vista IV Workstation Standard
Basic software module with color graphics, alarm handling, authority/security, scheduling, trend logging
and data backup functionality.
Color Graphics
Dynamic color graphics Display and control Hierarchical image links Real-time data acquisition Simultaneous display of several graphics on one screen Dynamic trend curves
Alarm Handling
Alarm and status monitoring Color-coded alarm display with information text Time and/or event-controlled alarm output on one or several printers 1000 alarm priority levels Real time error message processing Alarm interlocking Selection and sorting options for alarm summary Alarm links to reports, color graphics, trend charts and text files Alarm repetition block Error report statistics Audible and visual alarm reports Error report acknowledgement
Access Control
User identification Specified access authorisation for all users Standby log out function Automatic log out function Encrypted passwords and NT security
Backup
Seamless recording of all system data
Time Schedule
Automatic daylight savings correction Automatic leap year function Weekly and alternative time programs System time synchronisation Supports system distributed over several time zones
Trend Viewer
Variety of calculation functions Time and event controlled activation Post editing option of recorded values Recording interval of 10 seconds to 10 years Dynamic trend curves Graphic display and evaluation of online values and trend logs Easy operation based on the Microsoft Windows standard Export of values to other applications such as Microsoft Excel Variety of graphical presentation options
21
TAC Vista®IV
19
Product Catalogue • Revision 1.1 • August 2004
Event Viewer
Acquisition and storage of all events that occur in the system (system diary):
Database based on Microsoft
®
Access Chronological acquisition of event data within the system when entering date, time, command carried out and the corresponding user Recording of events and commands Clearly arranged display of event data
System Documentation
System configuration Process units Object list Data point list Data point checklist Fixed values
T A C V i s t a I V W o r k s t a t i o n S t a n d a r d . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7965-0
TAC Vista IV Workstation Standard (cont’d)
TAC Vista IV Workstation Manager
Basic software module with color graphics, alarm handling, authority/security, scheduling, trend logging and data backup functionality.
TAC Vista IV Workstation Manager has the same functionality as TAC Vista IV Workstation Standard, and includes the following additional features:
TAC Vista IV Workstation Manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7966-0
Report Generator
Standard software based on Microsoft Excel Form and content of the displays can be freely configured Wide range of options for editing the acquired data Complete support for Microsoft Excel presentation formats such as lines, bars and pie charts Reports can be printed on demand, or as scheduled Wide range of options for text entry, preparation of graphics and calculation Standardised formats or customised reports Display on screen or printed on one or several printers
Signature
Dynamic data exchange or manual data entry Budget management and control Energy profile Energy usage reports Degree days calculation Consumption can be displayed based on a range of parameters
TAC Vista®IV
2220
Product Catalogue • Revision 1.1 • August 2004
Color Graphic Editor
Extensive standard symbol library Symbol editor Run-time simulation Unrestricted tool positioning Multiple graphics Import of graphics in .bmp .gif .jpg .pcx .tif formats Dynamic and animated graphics and creation of dynamic links
TAC Menta
®
Easy graphical programming Large functions and applications library Definition of LonWorks variables (SNVTs) as XIF file Offline simulation Online operating functions Dynamic online trend Documentation support Download of software to TAC Xenta controllers Fully integrated with the TAC Vista database Definition of menu structure for the TAC Xenta Operator Panel
OPCTool
Integration of OPC-servers in the TAC Vista IV database Simple operation based on the Microsoft Windows standard Structures and objects can be imported from external OPC servers
WebTool
Software tool for generating Web pages in HTML format and for setting product parameters:
TAC Xenta 511 Webserver Version 1 TAC Vista IV Webstation
CIPCL Editor
Programming language for logical and special functions in the server Source file preparation Program code conversion
IPCL Editor
Programming language for logical and special functions for the controller family TA 65XX and 67XX Source file preparation Download of software to the controllers
Database Generator
Copying, processing and reusing existing system data from other projects Data import, export and conversion Conversion and adaptation of system information in the TAC Vista database
TAC Vista IV Workstation Professional
Basic software module with color graphics, alarm handling, authority/security, scheduling, trend logging and data backup functionality.
TAC Vista IV Workstation Professional contains the same functionality as the TAC Vista IV Workstation Manager, but in addition includes the following features:
TAC Vista IV Workstation Professional . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7967-0
23
TAC Vista®IV
21
Product Catalogue • Revision 1.1 • August 2004
TAC Vista IV Webstation
The software module TAC Vista IV Webstation gives access to TAC Vista IV systems using a standard Web browser via the Intranet /Internet. The following operating functions are supported:
Display and acknowledge alarms Read and write values Dynamic color graphics Trend logging Historical events Reports and charts
T A C V i s t a I V W e b s t a t i o n S e r v e r . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7995-0
T A C V i s t a I V W e b s t a t i o n E x p a n s i o n 3 u s e r s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7996-0
T A C V i s t a I V W e b s t a t i o n E x p a n s i o n 6 u s e r s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7997-0
TAC Vista IV Webstation Expansion 12 users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7998-0
TAC Vista IV Webstation Expansion 24 users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7999-0
TAC Vista IV Webstation Upgrade of Webstation 2.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-8000-0
TAC Vista ScreenMate (Virtual Room Unit)
Room control via the Intranet on a PC workstation:
Virtual room control device as monitor image Individualised control configuration Variable setting of room functions such as: – Dimming lights – Switching lights – Adjusting blinds – Change setpoints – Display of actual values
TAC Vista ScreenMate 10 users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7910-0
TAC Vista ScreenMate 100 users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7911-0
TAC Vista ScreenMate 500 users . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7912-0
TAC Vista®IV
2422
Product Catalogue • Revision 1.1 • August 2004
TAC Vista IV OPC Client
Software module for communicating with a wide range of third party drivers via an OPC server. More than 100 OPC servers are available for integrating devices and systems from other manufacturers.
Drivers are available for the following communication protocols: ABB Master – Alfa Laval Automation – Andover – BACnet – BAS2800 – CAN – Carrier CCN – CSI
Danfoss Danduc – EIB – Exomatic – Fabec/Tateco AB – FIX – Interbus-S – JCI – Landis & Gyr Modicon Modbus – Panasonic – Profibus – Saia S-Bus – Toshiba – Telefrang N45 – TREND IQ70 Siemens S7, H1, L2 – Siematic – York YT – Zerberus
Additional information and supply sources are available on request.
T A C V i s t a I V O P C C l i e n t . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7948-0
TAC Vista OPC Server
A software module for open access, via an OPC standard interface, to the TAC Vista IV server. Provides LonWorks network object data (nodes, network variables) as OPC objects in a continuously updated database and carries out all the packaging, converting and updating required for these objects:
TAC Vista OPC Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7949-0
Client/server architecture Easy and convenient access to TAC Vista via OPC
Automatic updating Suitable for large data quantities
LNS®Server
The Echelon®LNS Server is used to expand the TAC Vista IV Server so that it can communicate with LonWorks devices directly via LNS. The LNS-Server is required for systems where LonMaker®is not installed.
L N S S e r v e r . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7950-0
TAC Vista IV Report Generator
Software module that independently generates clear and informative reports and overviews, such as alarm and maintenance reports, status reports, trend logging reports as well as special user-defined reports, diagrams and overviews:
TAC Vista IV Report Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7975-0
Standard software based on Microsoft Excel Form and content presentation can be freely configured Wide range of options for editing acquired data Complete support for Microsoft Excel presentation options such as lines, bars and pie charts
Report printing on demand, or as scheduled Wide range of options for text entry, preparation of graphics and calculation Standard formats or customised reports Display on screen or printed to one or several printers
25
TAC Vista®IV
23
Product Catalogue • Revision 1.1 • August 2004
TAC Menta
High-performance engineering tool for unrestricted graphics programming and operation of TAC Xenta controllers:
T A C M e n t a . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7983-0
Easy graphical programming Extensive function and application library Definition of LonWorks variables (SNVTs) as XIF file Offline simulation Online operating functions Dynamic online trend Documentation support Download of software to TAC Xenta controllers Fully integrated with the TAC Vista database Definition of menu structures for the TAC Xenta Operator Panel
TAC Vista IV Color Graphic Editor
A high performance stand-alone software module for creating and editing dynamic system images. A broad range of drawing tools, symbols and functions allows customised and efficient color graphic creation:
TAC Vista IV Color Graphic Editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7977-0
Extensive standard symbol library Symbol editor Run time simulation Unrestricted tool positioning
Multiple graphics Import of .bmp .gif .jpg .pcx .tif graphics files Dynamic and animated graphics as well as creation of dynamic links
TAC Vista IV OPCTool
Software module for the integration of OPC servers into the TAC Vista IV database (clients). It is easy to operate and based on the Microsoft Windows standard. This minimises the work required to configure the OPC client in the TAC Vista IV server database. Structures and objects are imported into this from external OPC servers.
T A C V i s t a I V O P C T o o l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7978-0
TAC Vista®IV
2624
Product Catalogue • Revision 1.1 • August 2004
TAC XBuilder
TAC XBuilder is the programming tool for TAC Xenta 511, (version 2.0 and later), TAC Xenta 913 and TAC Xenta 527. TAC XBuilder addresses the programming task from the end user point of view, instead of from the device point of view. TAC XBuilder is a project oriented tool, which means that all data in an application will be stored in a project container.
T A C X B u i l d e r . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-8034-0
TAC Vista IV WebTool
A software tool for creating Web pages in HTML format and configuring TAC Xenta 511 so that they can be accessed using a standard Web browser. It is also used to create value pages for TAC Webstation.
T A C V i s t a I V W e b T o o l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7979-0
TAC Xenta 511 Webserver (Version 1) TAC Vista IV Webstation (value pages)
TAC Vista IV Database Generator
Software module for the efficient processing of project specific system data
TAC Vista IV Database Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7982-0
Copying, editing and reusing existing system data from other projects Data import, export and conversion
Conversion and adaptation of system information in the TAC Vista IV database
TAC Vista IV Signature
Stand-alone energy management software for the optimal analysis of large data volumes:
TAC Vista IV Signature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7876-0
Dynamic data exchange or manual data entry Budget management and control Energy profiles
Energy usage reports Degree days calculation Consumption can be displayed based on a range of parameters
27
TAC Vista®IV
25
Product Catalogue • Revision 1.1 • August 2004
TAC Vista IV Communication SYSTEM 7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7947-0
TAC Vista IV Communication SYSTEM 7
Software module for communication with the TAC ZONE II and SYSTEM 7 systems. It supports PLB, KE11 and LCU-C communication interfaces and a dedicated/dial-up line connection is used for remote monitoring and/or remote control. Geographically remote systems can be connected via a modem. Automatic bi-directional dial-up (Auto Dial) is used for requests, changing values and for transferring alarms.
TAC Vista IV CIPCL Editor
High-level language for efficient programming of special functions in the TAC Vista IV Server:
T A C V i s t a I V C I P C L E d i t o r . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7981-0
Programming language for logical and special functions in the server
Source file preparation Program code conversion
TAC Vista IV IPCL Editor
High-level language for programming logical functions in TAC ZONE II and TAC SYSTEM 7 systems:
TAC Vista IV IPCL Editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7980-0
Programming language for logical and special functions in the controller family TA 65XX and 67XX
Source file preparation Download of software to the controllers
Product Catalogue • Revision 1.1 • August 2004
26
Product Catalogue • Revision 1.1 • August 2004
27
Engineering Tools
Product Catalogue • Revision 1.1 • August 2004
28
Engineering Tools
TAC Menta . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
TAC WebTool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
TAC XBuilder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
TAC OPCTool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
LonMaker Integration Tool. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Loytec LonWorks Protocol Analyzer . . . . . . . . . . . . . . . . . . . . . . . . 31
Product Catalogue • Revision 1.1 • August 2004
29
Engineering Tools
TAC Menta
®
Fully featured, graphical engineering tool for programming, commissioning and operating TAC Xenta®controllers:
Easy graphical programming Wide range of functions and application libraries Trend logging, scheduling and alarm definitions Automatic creation of LonWorks®object files in XIF format Offline simulation Single step execution Online operating functions Dynamic online trend Documentation support
Downloading of software to TAC Xenta controllers Fully integrated with the TAC Vista®database Definition of the menu structure for the TAC Xenta OP, Operator Panel
T A C M e n t a C D L P T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-8025-0
T A C M e n t a C D U S B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-8026-0
TAC WebTool
TAC WebTool is used to program and configure TAC Xenta 511 version 1.0. TAC Graphics Editor is included for graphics pages creation. For later versions of TAC Xenta 511 use TAC XBuilder. TAC WebTool is also used to create value pages for TAC Webstation.
TAC Xenta 511 Webserver (Version 1.0) TAC Vista Webstation (value pages)
T A C W e b To o l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7979-0 T A C W e b To o l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7979-0
Engineering Tools
3230
Product Catalogue • Revision 1.1 • August 2004
TAC XBuilder
TAC XBuilder is the programming tool for TAC Xenta 511, (version 2.0 and later). XBuilder addresses the programming task from the end user point of view, instead of from the the device point of view. XBuilder is a project oriented tool, which means, all data in an application will be stored in a project container.
The user interface is intuitive and customisable with four main windows:
System: Describes the logical system with objects and connections Network: Describes the physical implementation of the system with objects Properties: Describes the the properties of the selected object in the System or Network window Output: Informs the user about errors and warnings in the project
TAC Vista OPCTool
The TAC Vista OPCTool is a tool used for browsing OPC servers and automatically programming the TAC Vista database. In specific, this tool is used for TAC OPC server for Danduc, I/Net OPC server or any other OPC server supporting OPC Data Access,
Alarm & Events or Historical Data.
Programming the TAC Vista database involves choosing the signals and trend logs you need to generate and operate. After generation of the objects, TAC Vista will be able to communicate with any equipment that is handled by an OPC server.
TAC Vista OPCTool can be used to perform these tasks:
Locate OPC servers locally or on any node of a network Browse the hierarchy of items in the OPC server
Create and update objects for the TAC Vista database Substitute unsupported characters in OPC servers Log result to a log file
T A C W e b To o l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7979-0 T A C X B u i l d e r . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-8034-0
T A C W e b To o l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7979-0 T A C O P C T o o l . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-008-7978-0
Loading...
+ 109 hidden pages