Samsung NE59T4311SS, NE59J7850WS Installation manual

0 (0)

Electric Range

installation manual

imagine the possibilities

Thank you for purchasing this Samsung product.

Install_30_Electric_Range_USA_DG68-00108G-09_EN+MES.indb 1

 

 

2018-07-31 3:48:02

 

 

 

 

 

 

before you begin

ANTI-TIP DEVICE

WARNING: To reduce the risk of tipping the appliance, the appliance must be WARNING secured by properly installed anti-tip devices packed with the appliance.

a) A child or adult can tip the range and be killed.

b) Install the anti-tip device to the structure and/or the range at rear right (or rear left) of the range bottom.

c) Engage the range to the anti-tip device by leveling leg at rear right (or rear left) of the range bottom.

d)Re-engage the anti-tip device if the range is moved.

e)See installation instructions for details.

f) Failure to do so can result in death or serious burns to children or adults.

ABOUT THIS MANUAL

READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY.

Important note to the installer

Read all instructions contained in these installation instructions before installing range.

Remove all packing materials from the oven compartments before connecting the electrical supply to the range.

Observe all governing codes and ordinances.

Be sure to leave these instructions with the consumer.

Important note to the consumer

Keep these instructions for the local electrical inspector’s use.

As when using any appliance generating heat, there are certain safety precautions you should follow.

Be sure your range is installed and grounded properly by a qualified installer or service technician.

Make sure the wall coverings around the range can withstand the heat generated by the range.

To eliminate the need to reach over the surface elements, cabinet storage space above the elements should be avoided.

The range should not be placed on a base.

FOR YOUR SAFETY

WARNING WARNING If the information in this manual is not followed exactly, a fire or electrical shock may result causing property damage, personal injury or death.

WARNING WARNING Before beginning the installation, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

WARNING WARNING This appliance must be properly grounded.

English - 2

Install_30_Electric_Range_USA_DG68-00108G-09_EN+MES.indb 2

 

 

2018-07-31 3:48:02

 

 

 

 

 

 

preparing to install the range

REMOVE PACKAGING

Remove packaging materials. Failure to remove packaging materials could result in damage to the appliance.

PREPARE TOOLS & PARTS

What tools you will need

Drill

Adjustable Wrench

Pliers

1/4" Nut Driver

Phillips Screwdriver

Flat Screwdriver

Pencil

Level

What’s included with your range

Template

Anti-Tip Bracket

Screws (4 ea)

What’s not included

4-Wire Cord or 3-Wire Cord

Strain Relief

(UL Approved 40 or 50 AMP)

(For Conduit Installation Only)

English - 3

RANGE THE INSTALL TO PREPARING & BEGIN YOU BEFORE 01

Install_30_Electric_Range_USA_DG68-00108G-09_EN+MES.indb 3

 

 

2018-07-31 3:48:03

 

 

 

 

 

 

CHECKING THE INSTALLATION SITE

Clearances and dimensions

To install the range, refer to the following figure.

For installation in CANADA, a Free-standing range is not to be installed closer than 12mm from any adjacent surface.

CAUTION CAUTION This range has been designed to comply with the maximum allowable wood cabinet temperatures of 194 °F. Make sure the wall covering, countertops and cabinets around the range can withstand the heat (up to 194 °F) generated by the range. If not, discoloration, delamination or melting may occur.

 

3"

 

25"

24"

3"

 

 

 

19/16"

297/8"

6" B

 

247/8"

287/16"

 

36" ~ 37"

 

A

 

 

261/16"

 

 

461/2" ~ 471/2"

 

71/2"

 

 

2915/16"

493/8"

 

 

 

 

 

241/2"

 

A : Cabinet opening

30" For U.S.A, 30"~31" For CANADA.

B : Acceptable electrical outlet area

Minimum dimensions

IMPORTANT To eliminate the risk of burns or fire caused by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5" beyond the bottom of the cabinets.

 

30"

 

 

 

* 30"

 

 

** 15"

*

30" minimum clearance between the top

 

 

of the cooking surface and the bottom of

 

 

 

 

 

 

an unprotected wood or metal cabinet;

 

 

 

or 24" minimum when the bottom of the

 

 

 

wood or metal cabinet is protected by not

 

 

 

less than 1/4" flame retardant millboard

 

 

 

covered with not less than no.28 MSG

 

 

 

sheet steel, 0.015" stainless steel, 0.024"

 

 

 

aluminum or 0.020" copper.

 

 

**

15" minimum between the countertop and

 

 

 

the adjacent cabinet bottom.

 

 

English - 4

 

 

Install_30_Electric_Range_USA_DG68-00108G-09_EN+MES.indb

4

2018-07-31

3:48:03

connecting the power

STEP 1. MEETING ELECTRICAL CONNECTION REQUIREMENTS

CAUTION CAUTION For personal safety, do not use an extension cord with this appliance. Remove house fuse or open circuit breaker before beginning installation.

This appliance must be supplied with the proper voltage and frequency, and connected to an individual properly grounded branch circuit, protected by a circuit breaker or fuse having amperage as specified on the rating plate. The rating plate is located above the drawer on the oven frame. (Fig. 1 or Fig. 2)

We recommend you have the electrical wiring and hookup of your range connected by a qualified electrician. After installation, have the electrician show you where your main range disconnect is located.

Check with your local utilities for electrical codes which apply in your area. Failure to wire your oven according to governing codes could result in a

hazardous condition. If there are no local codes, your range must be wired and

fused to meet the requirements of the National Electrical Code, ANSI/NFPA No. (Fig. 1) 70–Latest Edition. You can get a copy by writing:

National Fire Protection Association

Batterymarch Park

Quincy, MA 02269

(Fig. 2)

Effective January 1, 1996, the National Electrical Code requires that new construction (not existing) utilize a 4-conductor connection to an electric range.

When installing an electric range in new construction, follow Steps 2 and 3 for 4-wire connection.

You must use a 3-wire or 4-wire, single-phase A.C. 208Y/120 Volt or 240/120 Volt, 60 hertz electrical system.

If the electrical service provided does not meet the above specifications, have a licensed electrician install an approved outlet.

Use only a 3-conductor or a 4-conductor UL-listed range cord. These cords may be provided with ring terminals on wire and a strain relief device.

A range cord rated at 40 amps with 125/250 minimum volt range is required. A 50 amp range cord is not recommended but if used, it should be marked for use with nominal 138" diameter connection openings. Care should be taken to center the cable and strain relief within the knockout hole to keep the edge from damaging the cable.

Because range terminals are not accessible after range is in position, flexible service conduit or cord must be used.

NOTE If conduit is being used, go to Step 4 on page 9.

ALL NEW BRANCH-CIRCUIT CONSTRUCTIONS, MOBILE HOMES, RECREATIONAL VEHICLES AND INSTALLATIONS WHERE LOCAL CODES DO NOT ALLOW GROUNDING THROUGH NEUTRAL, REQUIRE A 4-CONDUCTOR UL-LISTED RANGE CORD.

English - 5

POWER THE CONNECTING02

Install_30_Electric_Range_USA_DG68-00108G-09_EN+MES.indb 5

 

 

2018-07-31 3:48:04

 

 

 

 

 

 

STEP 2. ACCESSING THE POWER CORD CONNECTION

Remove the rear access cover and loosen the screw with a screwdriver. The terminal block will then be accessible.

Terminal block

Access cover

Specified power-supply-cord kit rating

Range rating, watts

Specified rating of

Diameter (inches) of range

connection opening

 

 

 

 

power-supply-cord kit,

 

 

120 / 240 volts

120 / 208 volts

 

 

amperes

Power cord

Conduit

3-wire

3-wire

 

 

 

 

 

 

 

 

 

8,750 - 16,500

7,801 - 12,500

40 or 50A

13/8"

11/8"

English - 6

Install_30_Electric_Range_USA_DG68-00108G-09_EN+MES.indb 6

 

 

2018-07-31 3:48:04

 

 

 

 

 

 

Samsung NE59T4311SS, NE59J7850WS Installation manual

STEP 3. INSTALLING THE POWER CORD

For power cord installations, hook the strain relief over the power cord hole (13/8") located below the rear of the drawer body. Insert the power cord through the strain relief and tighten the device.

Conduit connection plate

Power cord

Strain relief

You must install the power cord with a strain relief.

Attach the strain relief to the 13/8" opening in conduit connection plate.

Installing a 3-wire power cord

WARNING WARNING The neutral or ground wire of the power cord must be connected to the neutral terminal located in the center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block.

1.Remove the 3 lower terminal screws from the terminal block.

2.Insert the 3 terminal screws through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block.

3.Tighten screws securely into the terminal block. DO NOT remove the ground strap connection.

4.Go to step 5 on page 10 and proceed with the installation.

Neutral

Ground strap

terminal

White

Black

Red

Live 1

 

Live 2

Black White

Red

CAUTION CAUTION You must check voltage after connecting power cord.

Live 1

- Neutral

120

V

 

 

 

 

 

 

Live 2

- Neutral

120

V

 

 

 

 

 

 

Live 1

- Live 2

208

V / 240 V

 

 

 

 

 

 

 

 

 

 

 

English - 7

POWER THE CONNECTING02

Install_30_Electric_Range_USA_DG68-00108G-09_EN+MES.indb 7

 

 

2018-07-31 3:48:04

 

 

 

 

 

 

Installing a 4-wire power cord

WARNING WARNING The neutral wire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. The 4th grounding lead must be connected to the frame of the range with the ground plate and the ground screw.

1.Remove the 3 lower terminal screws from the terminal block. Remove the ground screw and ground plate and retain them.

2.Cut and discard the ground strap. Do not discard any screws.

3.Insert the one ground screw into the power cord ground wire terminal ring, through the ground plate, and into the frame of the range.

4.Insert the 3 terminal screws (removed earlier) through each power cord terminal ring and into the lower terminals of the terminal block. Be certain that the center wire (white/neutral) is connected to the center lower position of the terminal block. Tighten screws securely into the terminal block.

5.Go to step 5 on page 10 and proceed with the installation.

Live 1

Ground strap

White

Black

Red

Neutral terminal

Live 2

Ground plate

Black

White

Red

 

 

 

 

Ground

Ground

 

wire (Green)

 

screw

 

 

CAUTION CAUTION You must check voltage after connecting power cord.

Live 1

- Neutral

120

V

 

 

 

 

 

 

Live 2

- Neutral

120

V

 

 

 

 

 

 

Live 1

- Live 2

208

V / 240 V

 

 

 

 

 

 

 

 

 

 

 

English - 8

Install_30_Electric_Range_USA_DG68-00108G-09_EN+MES.indb 8

 

 

2018-07-31 3:48:04

 

 

 

 

 

 

Loading...
+ 16 hidden pages