Safety Precautions

(Carefullyfollowtheprecautionslistedbelowbecausetheyareessentialtoguaranteethesafetyoftheequipment.)

Alwaysdisconnecttheairconditionerfromthepowersupplybeforeservicing WARNING itoraccessingitsinternalcomponents.

Verifythatinstallationandtestingoperationsareperformedbyqualified personnel.

Verifythattheairconditionerisnotinstalledinaneasilyaccessiblearea.

GENERAL INFORMATION

Carefullyreadthecontentofthismanualbeforeinstallingtheairconditionerandstorethemanualinasafeplaceinorderto beabletouseitasreferenceafterinstallation.

Formaximumsafety,installersshouldalwayscarefullyreadthefollowingwarnings.

Storetheoperationandinstallationmanualinasafelocationandremembertohanditovertothenewowneriftheair conditionerissoldortransferred.

ThismanualexplainshowtoinstallanindoorunitwithasplitsystemwithtwoSAMSUNGunits.Theuseofothertypesof unitswithdifferentcontrolsystemsmaydamagetheunitsandinvalidatethewarranty.Themanufacturershallnotbe responsiblefordamagesarisingfromtheuseofnoncompliantunits.

Themanufacturershallnotberesponsiblefordamageoriginatingfromunauthorizedchangesortheimproperconnectionofelectric andrequirementssetforthinthe“Operatinglimits”table,includedinthemanual,shallimmediatelyinvalidatethewarranty.

Theairconditionershouldbeusedonlyfortheapplicationsforwhichithasbeendesigned:theindoorunitisnotsuitableto beinstalledinareasusedforlaundry.

Donotusetheunitsifdamaged.Ifproblemsoccur,switchtheunitoffanddisconnectitfromthepowersupply.

Inordertopreventelectricshocks,firesorinjuries,alwaysstoptheunit,disabletheprotectionswitchandcontactSAMSUNG’ stechnicalsupportiftheunitproducessmoke,ifthepowercableishotordamagedoriftheunitisverynoisy.

Alwaysremembertoinspecttheunit,electricconnections,refrigeranttubesandprotectionsregularly.Theseoperations shouldbeperformedbyqualifiedpersonnelonly.

Theunitcontainsmovingparts,whichshouldalwaysbekeptoutofthereachofchildren.

Donotattempttorepair,move,alterorreinstalltheunit.Ifperformedbyunauthorizedpersonnel,theseoperationsmay causeelectricshocksorfires.

Donotplacecontainerswithliquidsorotherobjectsontheunit.

Allthematerialsusedforthemanufactureandpackagingoftheairconditionerarerecyclable.

Thepackingmaterialandexhaustbatteriesoftheremotecontrol(optional)mustbedisposedofinaccordancewithcurrentlaws.

Theairconditionercontainsarefrigerantthathastobedisposedofasspecialwaste.Attheendofitslifecycle,theaircondi tionermustbedisposedofinauthorizedcentersorreturnedtotheretailersothatitcanbedisposedofcorrectlyandsafely.

INSTALLING THE UNIT

IMPORTANT: Wheninstallingtheunit,alwaysremembertoconnectfirsttherefrigeranttubes,thentheelectricallines.

Alwaysdisassembletheelectriclinesbeforetherefrigeranttubes.

Uponreceipt,inspecttheproducttoverifythatithasnotbeendamagedduringtransport.Iftheproductappearsdamaged, DONOTINSTALLitandimmediatelyreportthedamagetothecarrierorretailer(iftheinstallerortheauthorizedtechnician hascollectedthematerialfromtheretailer.)

Aftercompletingtheinstallation,alwayscarryoutafunctionaltestandprovidetheinstructionsonhowtooperatetheair conditionertotheuser.

Donotusetheairconditionerinenvironmentswithhazardoussubstancesorclosetoequipmentthatreleasefreeflamesto avoidtheoccurrenceoffires,explosionsorinjuries.

POWER SUPPLY LINE, FUSE OR CIRCUIT BREAKER

Alwaysmakesurethatthepowersupplyiscompliantwithcurrentsafetystandards.Alwaysinstalltheairconditionerin compliancewithcurrentlocalsafetystandards.

Alwaysverifythatasuitablegroundingconnectionisavailable.

Verifythatthevoltageandfrequencyofthepowersupplycomplywiththespecificationsandthattheinstalledpowerissuf ficienttoensuretheoperationofanyotherdomesticapplianceconnectedtothesameelectriclines.

Alwaysverifythatthecut-offandprotectionswitchesaresuitablydimensioned.

Verifythattheairconditionerisconnectedtothepowersupplyinaccordancewiththeinstructionsprovidedinthewiring diagramincludedinthemanual.

Alwaysverifythatelectricconnections(cableentry,sectionofleads,protections…)arecompliantwiththeelectricspecifica tionsandwiththeinstructionsprovidedinthewiringscheme.Alwaysverifythatallconnectionscomplywiththestandards applicabletotheinstallationofairconditioners.

E-2

ENGLISH

 

Contents

 

PREPARING THE INSTALLATION

 

DecidingonWheretoInstalltheAirConditioner ......................

4

AirConditionerandAccessories ......................................

12

INSTALLING THE INDOOR UNIT

 

InstallingandConnectingtheOutdoorUnitDrainHose ............................

13

Cutting/ExtendingthePiping ........................................

14

INSTALLINGTHE OUTDOOR UNIT

 

ConnectingtheCablestotheOutdoorUnit ...........................

15

TransmitterInstallation(Optional) ....................................

19

CheckingCorrectEarthing ...........................................

22

FixingtheUnitinPosition .............................................

22

COMPLETINGTHE INSTALLATION

 

ConnectingUpandPurgingtheCircuit ...............................

23

AddingRefrigerant ...................................................

24

PerformingLeakTests ................................................

25

PipeInstallationwithIndoorUnits ....................................

26

SwitchSettingandTestingOperation .................................

27

Troubleshooting .....................................................

33

ExplainingOperationstotheOwner...................................

34

COMBINATIONTABLE

 

E-3

PREPARINGTHE INSTALLATION

Deciding onWhere to Install the AirConditioner

Whendecidingonthelocationoftheairconditionerwiththeowner,thefollowingrestrictions mustbetakenintoaccount.

General

DoNOTinstalltheairconditionerinalocationwhereitwillcomeintocontactwiththefollowingelements:

Combustiblegases

Salineair

Machineoil

Sulphidegas

Specialenvironmentalconditions

Ifyoumustinstalltheunitinsuchconditions,firstconsultyourdealer.

OutdoorUnit

TheoutdoorunitmustNEVERbeplacedonitssideorupsidedown,asthecompressorlubricationoilwillruninto thecoolingcircuitandseriouslydamagetheunit.

Choosealocationthatisdryandsunny,butnotexposedtodirectsunlightorstrongwinds.

Donotblockanypassagewaysorthoroughfares.

Choosealocationwherethenoiseoftheairconditionerwhenrunningandthedischargedairdonotdisturbany neighbours.

Chooseapositionthatenablesthepipingandcablestobeeasilyconnectedtotheindoorunitandtherecommendedlengthwillberespected.

Installtheoutdoorunitonaflat,stablesurfacethatcansupportitsweightanddoesnotgenerateanyunnecessary noiseandvibration.

Positiontheoutdoorunitsothattheairflowisdirectedtowardstheoutside,asindicatedbythearrowsonthetop oftheunit.

Maintainsufficientclearancearoundtheoutdoorunit,asindicatedinthediagramonthepageopposite.

Makesurethatthewaterdrippingfromthedrainhoserunsawaycorrectlyandsafely.

CAUTION

YouhavejustpurchasedaFreeJointMultiairconditionerandithasbeeninstalledbyyour installationspecialist.

Thisdevicemustbeinstalledaccordingtothenationalelectricalrules.

Maxinputpower&currentismeasuredaccordingtoIECstandardandinputpower&currentis measuredaccordingtoISOstandard.

Morethan2indoorunitsshouldbeinstalledwhenyouuseFreeJointMultiairconditioner.

Theunitsmustbeinstalledaccordingtodistancesdeclared,inordertopermitaccessibilityfrom eachside,eithertoguaranteecorrectoperationofmaintenanceorrepairingproducts.Theunit’s partsmustbereachableandremovablecompletelyundersafetycondition(forpeopleorthings).

Thecostneededtoreachandrepairtheoutdoorunit(inSAFETYCONDITIONaccordingtodecreeof law626/94),installedabove3.0metersheight(fromthefloor)willbechargedtofinalcustomer.

Withanoutdoorunithavingnetweightupperthen60kg,wesuggestdonotinstallitsuspendedon wall,butconsideringfloorstandingone.

E-4

PREPARINGTHE INSTALLATION

MH040FXA2B

Piping outsidediameter

Indoorunit

Outdoorunit

Powersupply

 

Unit

Outsidediameter

Ø,V,Hz

 

Liquid

Gas

 

 

 

 

020/023/026/035

MH040FXA2B

1,220-240,50

 

 

 

 

 

020/023/026/035

1/4"

3/8"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MH040FXA2Boutdoorunitcannotbeconnectedtothefollowingindoorunitcombination. -052/MHFMA/MHFEA/MHFUA

 

200mm

 

 

 

ormore

 

 

100mm

 

160mm

 

ormore

 

ormore

 

CAUTION:

 

(h)

(H)

3masminimumpipelength:Itwillreduce

 

 

noiseandvibration.

 

 

 

Thisvaluemustbeincreasedat7.5metersin

 

 

caseitisconnectedjustoneindoorunit.

 

 

 

600mm

 

 

 

minimum

A

B

 

 

 

300mm

300mm

 

 

minimum

 

 

 

minimum

 

 

600mm

 

 

 

minimum

 

 

 

Piping lengthand the height

 

1Roommax

2Roomtotalmax

Maxheightbetween

Maxheightbetween

 

length

length

indoorunit&outdoorunit

indoorunits

Dimension

20m

30m

15m

7.5m

Composition

A,B

A+B

(H)

(h)

Systemcanworkwithoneindoorunitconnected,butitisrecommendedthattheTOTALnumberof indoorunitsuggestedbymanufacturerareconnectedtoobtainthemaximumperformance.

Makeatleastoneround:

Itwillreducenoiseandvibration

Theappearanceoftheunitmaybedifferentfromthediagramdependingonthemodel.

ENGLISH

E-5

PREPARINGTHE INSTALLATION

Deciding onWhere to Install the AirConditioner (Continued)

MH050FXA2B

Indoorunit

Outdoorunit

Powersupply

Ø,V,Hz

 

 

020/023/026/035/052

MH050FXA2B

1,220-240,50

 

 

 

Piping outside diameter

Unit

Outsidediameter

Liquid

Gas

 

020/023/026/035

1/4"

3/8"

 

 

052

1/2"

 

MH052FXA2Boutdoorunitcannotbeconnectedtothefollowingindoorunitcombination. -MH052FMEA/MH052FUEA

 

200mm

 

 

 

 

ormore

 

 

 

100mm

 

 

160mm

 

ormore

 

 

ormore

 

CAUTION:

 

 

(h)

(H)

3masminimumpipelength:Itwillreduce

 

noiseandvibration.

 

 

 

 

Thisvaluemustbeincreasedat7.5meters

 

 

 

incaseitisconnectedjustoneindoorunit.

 

 

 

 

600mm

 

 

 

 

minimum

 

 

 

300mm

300mm

A

B

 

minimum

minimum

 

600mm

 

 

 

 

minimum

 

 

 

 

Piping length and theheight

 

 

Mainpowerswitch

 

 

 

 

 

 

 

 

 

 

 

1Roommax

2Roomtotalmax

Maxheightbetween

 

Maxheightbetween

 

length

length

indoorunit&outdoorunit

 

indoorunits

Dimension

20m

30m

15m

 

7.5m

Composition

A,B

A+B

(H)

 

(h)

Systemcanworkwithoneindoorunitconnected,butitisrecommendedthattheTOTALnumber ofindoorunitsuggestedbymanufacturerareconnectedtoobtainthemaximumperformance.

Makeatleastoneround:

Itwillreducenoiseandvibration

Theappearanceoftheunitmaybedifferentfromthediagramdependingonthemodel.

E-6

PREPARINGTHE INSTALLATION

MH060FXA3B

Piping outside diameter

Indoorunit

Outdoorunit

 

Powersupply

 

Ø,V,Hz

 

 

 

020/023/026/030/035/052

MH060FXA3B

 

1,220-240,50

 

 

 

 

 

 

200mm

 

 

ormore

Unit

Outsidediameter

Liquid

Gas

 

 

 

 

020/023/026/030/035

1/4"

3/8"

052

1/2"

 

 

 

 

100mm

 

160mm

 

 

ormore

 

ormore

 

 

CAUTION:

 

 

(h)

(H)

3masminimumpipelength:Itwillreduce

 

 

 

 

noiseandvibration.

 

 

 

 

Thisvaluemustbeincreasedat7.5metersin

 

 

 

caseitisconnectedjustoneindoorunit.

 

 

 

 

600mm

 

A

 

 

 

 

 

 

minimum

 

B

 

 

 

 

C

 

 

 

 

 

300mm

300mm

 

 

 

minimum

 

 

 

 

minimum

 

 

 

600mm

 

 

 

 

minimum

 

 

 

 

ENGLISH

Mainpowerswitch

Piping length and theheight

 

1Roommax

3Roomtotalmax

Maxheightbetween

Maxheightbetween

 

length

length

indoorunit&outdoorunit

indoorunits

Dimension

20m

45m

15m

7.5m

Composition

A,B,C

A+B+C

(H)

(h)

Systemcanworkwithoneindoorunitconnected,butitisrecommendedthattheTOTALnumber ofindoorunitsuggestedbymanufacturerareconnectedtoobtainthemaximumperformance.

Makeatleastoneround:

Itwillreducenoiseandvibration

Theappearanceoftheunitmaybedifferentfromthediagramdependingonthemodel.

E-7

PREPARINGTHE INSTALLATION

Deciding onWhere to Install the AirConditioner (Continued)

MH070FXA4B / MH080FXA4B

 

 

 

 

Pipingoutside diameter

 

 

 

 

 

 

 

 

 

 

Indoorunit

Outdoorunit

Powersupply

 

Unit

 

Outsidediameter

Ø,V,Hz

 

 

Liquid

Gas

 

 

 

 

 

 

MH070FXA4B

 

 

 

 

 

 

020/023/026/030/035/052

1,220-240,50

 

020/023/026/030/035

 

1/4"

3/8"

 

 

 

MH080FXA4B

 

052

 

1/4"

1/2"

 

 

 

 

 

 

200mm

 

 

 

 

 

ormore

 

 

 

 

100mm

 

160mm

 

 

 

 

ormore

 

 

 

ormore

 

 

 

 

 

 

 

 

CAUTION:

 

 

 

 

(h) (H)

3masminimumpipelength:Itwill

 

 

 

 

reducenoiseandvibration.

 

 

 

 

 

Thisvaluemustbeincreasedat7.5

 

 

 

 

metersincaseitisconnectedjustone

 

 

 

 

indoorunit.

 

 

 

 

 

 

600mm

 

 

 

 

 

minimum

A

B

C

D

300mm

 

300mm

 

 

 

 

minimum

 

 

 

minimum

 

 

 

 

 

 

 

 

 

600mm

 

 

 

 

 

minimum

 

 

 

 

 

 

 

 

Mainpowerswitch

 

 

Pipinglength andthe height

 

 

 

 

 

1Roommax

4Roomtotalmax

Maxheightbetween

 

Maxheightbetween

 

length

length

indoorunit&outdoorunit

 

indoorunits

Dimension

25m

70m

15m

 

7.5m

Composition

A,B,C,D

A+B+C+D

(H)

 

(h)

Systemcanworkwithoneindoorunitconnected,butitisrecommendedthattheTOTALnumber ofindoorunitsuggestedbymanufacturerareconnectedtoobtainthemaximumperformance.

Makeatleastoneround:

Itwillreducenoiseandvibration

Theappearanceoftheunitmaybedifferentfromthediagramdependingonthemodel.

E-8

PREPARINGTHE INSTALLATION

MH18VF1X/MH19VF1X

 

 

Piping outsidediameter

 

 

 

 

 

 

 

 

 

 

Indoorunit

Outdoorunit

Powersupply

 

Unit

 

OuterDiameter

Ø,V,Hz

 

 

Liquid

Gas

 

 

 

 

 

MH18VF1-09

MH18VF1X

 

 

 

 

 

 

 

 

MH18VF1-09

 

1/4"

3/8"

MH19VF1-07

MH19VF1X

1,220-240~,50

 

MH19VF1-07

 

MH19VF1-12

 

 

MH19VF1-12

 

 

 

 

 

 

 

 

 

 

Respecttheclearancesandmaximumlengthsindicatedinthediagrambelowwheninstallingtheunit.

CAUTION:

 

B-unit MH18VF1-09or

 

3masminimumpipelength:Itwillreduce

 

MH19VF1-12

 

noiseandvibration.

 

 

 

 

 

Thisvaluemustbeincreasedat7.5meters

 

 

incaseitisconnectedjustoneindoorunit.

 

 

200mm

 

 

 

ormore

A-unit

MH19VF1-07or

 

 

 

 

 

MH18VF1-09

(H)

 

 

(h)

100mm

 

160mm

 

ormore

 

ormore

 

 

600mm

A

B

 

 

minimum

 

 

 

300mm

 

300mm

 

 

 

minimum

 

 

minimum

 

 

 

 

 

 

 

600mm

 

 

 

 

minimum

 

 

 

 

 

 

 

Mainpowerswitch

 

Pipinglength and the height

 

 

 

 

1Roommax

2Roomtotalmax

Maxheightbetween

Maxheightbetween

 

length

length

indoorunit&outdoorunit

indoorunits

Dimension

20m

30m

15m

7.5m

Composition

A,B

A+B

(H)

(h)

Systemcanworkwithoneindoorunitconnected,butitisrecommendedthattheTOTALnumber ofindoorunitsuggestedbymanufacturerareconnectedtoobtainthemaximumperformance.

Makeatleastoneround:

Itwillreducenoiseandvibration

Theappearanceoftheunitmaybedifferentfromthediagramdependingonthemodel.

ENGLISH

E-9

PREPARINGTHE INSTALLATION

Deciding onWhere to Install the AirConditioner (Continued)

Space Requirements for Outdoor Unit

Wheninstalling1outdoorunit

Unit : mm

 

300 or more

Whenthe air outlet is opposite the wall

300 or more

150 or more

600 or more

When3 sides of the outdoor unit are blocked by the wall

more

300 or more

500 or

 

Theupper part of the outdoor unit and the air outlet is opposite the wall

1500 or more

Whenthe air outlet is towards the wall

 

or more

2000 or more

1500

 

Theupper part of the outdoor unit and the air outlet is towards the wall

1500 or more 300 or more

Whenfront and rear side of the outdoor unit is towards the wall

E-10

Samsung MH080FXEA4B, MH070FXEA4A, MH070FXEA4B Manual

Wheninstallingmorethan1outdoorunit

 

Unit : mm

 

 

 

 

 

 

 

 

1500 or more

Whentheairoutletistowardsthewall

 

 

 

 

 

 

300 or more

300ormore

600ormore

600ormore

600ormore

When3sidesoftheoutdoorunitareblockedbythewall

 

 

 

 

ormore 300 or more

600ormore

 

600ormore

1500

 

 

 

 

Whenfrontandrearsideoftheoutdoorunitistowardsthewall

1500ormore 600ormore

3000ormore

3000ormore

200ormore

Whenfrontandrearsideoftheoutdoorunitistowardsthewall

more

300ormore

 

 

 

500 or

 

 

 

 

 

 

 

more

300ormore

 

 

 

500 or

 

 

 

 

Theupper part of the outdoor unit and the air outlet is opposite the wall

PREPARINGTHE INSTALLATIO

ENGLISH

E-11

PREPARINGTHE INSTALLATION

Air Conditioner and Accessories

Thefollowingaccessoriesaresuppliedwiththeairconditioner.

Accessories in theOutdoorUnitCase

MH040FXA2B/MH050FXA2B/MH060FXA3B/MH18VF1X/MH19VF1X

 

 

3-wire

 

2-wire

 

DrainPlug

 

Transmitterpower

 

EnergyLabel

 

PowerCable

 

AssemblyCable

 

 

 

cable

 

 

 

 

 

 

(option)

 

(option)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RubberLeg

 

FlareBolt

 

InstallationManual

 

 

 

(Nut1/2”,Bolt3//8”)

 

 

 

 

 

(exceptMH040FXA2B)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AttachEnergyLabeltotheoutdoorunitproperlywheninstalling.

MH070FXA4B / MH080FXA4B

3-wire

2-wire

DrainPlug

Transmitterpower

InstallationManual

PowerCable

AssemblyCable

 

cable

 

(option)

(option)

 

 

 

RubberLeg

 

FlareNuts,6.35mm

 

FlareNuts,9.52mm

 

FlareBolt

 

EnergyLabel

 

 

 

 

outerpipediameter

 

outerpipediameter

 

(Nut1/2”,Bolt3/8”)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AttachEnergyLabeltotheoutdoorunitproperlywheninstalling.

The3-wirepowercableandthe2-wireassemblycableareoptional.Ifthesecablesarenotsupplied,usethe standardcableapprovedbyIECstandard.

Please,check“ConnectingtheCablestotheOutdoorUnit”section.

E-12