SAMSUNG MH060FXEA3B, MH052FXEA2, MH050FXEA2B, MH068FXEA4, MH052FXEA2A User Manual

0 (0)
ENGLISH
OWNERS INSTRUCTIONS
MANUAL DE INSTRUCCIONES
MANUEL DUTILISATION
ISTRUZIONI PER LUSO
MANUAL DE INSTRUÇÕES
GEBRAUCHSANWEISUNG
√¢∏°π∂™ Ã∏™∆∏
Free Joint Multi Air Conditioner
(Cool and Heat)
Acondicionador de aire libre del empalme multi
(Refrigeración y Calefacción)
Climatiseur Free Joint Multi
(Refroidissement et Chauffage)
Aria condizionata Free Joint Multi
(Raffreddamento e Riscaldamento)
Free Joint Multi ar condicionado
(Refrigeração e Aquecimento)
Free Joint Multi Klimaanlage
(Kühlen und Wärmen)
¶ФПП·Пfi ∫ПИМ·ЩИЫЩИОfi ªË¯¿ÓËÌ· ∂χıÂÚ˘ ŒÓˆÛ˘ (æ‡Í˘ - £¤ÚÌ·ÓÛ˘)
ååÌÌÓÓÓÓÙÙÛÛÌÌÍ͈ˆËËÓÓÌÌÎθ¸ÌÌ˚˚ÈÈ ÇÇÓÓÁÁÛÛ¯¯ÌÌ˚˚ÈÈ ääÓÓÌÌËˈˆËËÓÓÌÌ ëëÓÓ··ÓÓÌÌÓÓÓÓ ëëÓÓÂÂËËÌÌÂÂÌÌËË ((ééııÎÎÊÊÂÂÌÌËË ËË éé··ÓÓÂÂ))
ESPAÑOL
FRANÇAIS
ITALIANO
PORTUGUÊS
DEUTSCH
E S F I P D G R DB98-20234A(6)
MH020FPEA
MH023FPEA
MH026FPEA
MH035FPEA
MH052FPEA1
E§§HNIKA
RUSSIAN
E-2

Safety Precautions

The following safety precautions must be taken when using your air conditioner.
Users of this product are cautioned not to attempt repair of this product
at their own discretion. Instead, they are requested to directly contact a
designated service center or the outlet at which the product was
purchased.
Never spill any kind of liquid into the unit. Should this happen, unplug
or main switch off the unit and contact an authorized service center.
Do not insert anything between the air outlet blades because the inner
fan may be damaged and could cause injury. Keep children away from
the unit.
Do not place any obstacles in front of the unit.
Do not spray liquid of any kind into the indoor unit. Should this happen,
switch off the breaker used for your air conditioner and contact your
installation specialist.
Make sure that the unit is correctly ventilated at all times:
Do not place clothing or other materials over it.
If the wireless remote control will not be used for a long time, remove
the batteries. (If applicable)
When using a wireless remote control, the distance should not be more
than 7 meters from the air conditioner. (If applicable)
WARNING
DURING OPERATION
Never store or ship the air conditioner upside down or sideways to
avoid damage to the compressor.
The appliance is not intended for use by young children or infirm
persons without supervision: Young children should be supervised to
ensure that they do not play with the appliance.
Max current is measured according to IEC standard for safety and
current is measured according to ISO standard for energy efficiency.
O
THERS
Before throwing out the device, it is necessary to pull back the battery
cells and get rid of them safely for recycling reasons.
When you need to dispose of the unit, consult your dealer. If pipes are
removed incorrectly, refrigerant may blow out and come into contact
with your skin, causing injury. Releasing refrigerant into the atmosphere
also damages the environments.
Please recycle or dispose of the packaging material for this product in
an environmentally responsible manner.
D
ISPOSING OF THE UNIT
Risk of electric shock. Can cause injury or death. Disconnect all
remote electric power supplies before servicing, installing or cleaning.
This must be done by the manufacturer or its service agent or a similar
qualified person in order to avoid a hazard.
Register your product at www.samsung.com/global/register
E-3
ENGLISH
Contents
P
REPARING YOUR AIR CONDITIONER
Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
View of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Remote Control-Buttons and Display . . . . . . . . . . . . . . . . . . . . . . 6
Wired Remote Controller-Buttons and Display . . . . . . . . . . . . . . . 7
Centralized Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Function Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Getting Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Inserting the Remote Control Batteries . . . . . . . . . . . . . . . . . . . . . 12
O
PERATING YOUR AIR CONDITIONER
Selecting the Automatic Operating Mode . . . . . . . . . . . . . . . . . . . 13
Cooling Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Heating Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Changing the Room Temperature Quickly . . . . . . . . . . . . . . . . . . 16
Removing Excess Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Airing Your Room . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Adjusting the Air Flow Direction Vertically . . . . . . . . . . . . . . . . . . . 19
Adjusting the Air Flow Direction Horizontally . . . . . . . . . . . . . . . . 19
P
ROGRAMMING YOUR AIR CONDITIONER
Setting the On Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Setting the Off Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Setting the Sleep Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
R
ECOMMENDATIONS FOR USE
Operating Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Temperature and Humidity Ranges . . . . . . . . . . . . . . . . . . . . . . . . 24
Operating Your Air Conditioner Without the Remote Control . . . . . 24
Solving Common Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Cleaning Your Air Conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Cleaning Deodorizing and Bio Filters (Option) . . . . . . . . . . . . . . . 27
Correct Disposal of This Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems)
This marking shown on the product or its literature, indicates that it should not be disposed with other household
wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled
waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable
reuse of material resources.
Household users should contact either the retailer where they purchased this product, or their local government
office, for details of where and how they can take this item for environmentally safe recycling.
Business users should contact their supplier and check the terms and conditions of the purchase contract.
This product should not be mixed with other commercial wastes for disposal.

View of the Unit

E-4
If you want to turn On/Off the Display during operation,
press the button on the remote control.
The room temperature sensor senses air temperature around
the sensor, and shows the temperature on the display.
NN
NN
oo
oo
tt
tt
ee
ee
Indoor Unit
Air filter
(under the grille)
Air flow blades
(outlet)
Remote Control Sensor
On/Off switch
Timer indicator
Fan speed setting
Sleep Timer indicator
Operation indicator
Set temperature &
room temperature
Auto grille
Air Inlet
Room temperature sensor
The design and shape are subject to change according to the model.
E-5
ENGLISH
Outdoor Unit
MH040FXEA2 MH052FXEA2
Air Inlet (Rear)
Air Outlet
Connection Valve
Outdoor Unit
MH068FXEA4 MH080FXEA4
Air Inlet (Rear)
Air Outlet
Connection Valve
If the heat exchanger in the outdoor unit gets dusty, cooling efficiency may fall. So clean the
heat exchanger with water when it becomes dirty. However, be careful when you wash the
surface of the heat exchanger because it is very sharp.
NN
NN
oo
oo
tt
tt
ee
ee
E-6

Remote Control - Buttons and Display

Operating mode
( AUTO, COOL, DRY,
FAN, HEAT)
Remote control
transmission indicator
Off Timer setting
Sleep button
Swing button
Timer Set/Cancel button
Temperature adjustment
buttons
Temperature setting
Air flow direction
Turbo mode
Sleep mode
On/Off button
Mode selection button
(AUTO, COOL, DRY, FAN, HEAT)
Fan speed adjustment
button
Turbo button
On Timer button
Off Timer button
Fan speed
On Timer setting
Battery discharge indicator
Digital On/Off button
E-7
ENGLISH
The button is for your installation specialist. You must NOT press it.
After cleaning the air filter, press the button. Then the wired remote
controller will display the FILTER SIGN indicator when the time to clean the air filter;
refer to page 26 or 27.
NN
NN
oo
oo
tt
tt
ee
ee
Mode selection button
Communication
error indicator
On Timer setting
Off Timer setting
Test indicator
Timer Set/Cancel button
Test button
Temperature adjustment
buttons
Removing frost indicator
Operating mode
Centralized controller indicator
(In case of installing the Centralized controller)
Filter Reset button
Swing button
Temperature setting
Fan speed
Air flow direction
Filter Sign indicator
On/Off button
Fan speed
adjustment button
On/Off indicator
On Timer button

Wired Remote Controller-Buttons and Display

The wired remote controller is an optional accessory and it is installed on the wall.
To use the wired remote controller, refer to an appropriate manual.
E-8

Centralized Controller

The centralized controller is an optional accessory and it is installed on the wall.
To use the centralized controller, refer to an appropriate manual.
Operating lamp
All On button
All Off button
On/Off indicators
On/Off buttons
Index
The operating lamp comes on even when only one air conditioner
connected to the centralized controller is operating.
NN
NN
oo
oo
tt
tt
ee
ee
Front View
E-9
ENGLISH
Operating Mode Switch
COOL
AUTO
HEAT
Choose the appropriate operating mode with the Operating Mode Switch
that enables the user to choose between the Cool/Auto/Heat mode.
NN
NN
oo
oo
tt
tt
ee
ee
Side View
Loading...