Safety Precautions

The following safety precautions must be taken when using your air conditioner.

W A R N IN G

Risk of electric shock. z Can cause injury or death. z Disconnect all

remote electric power supplies before servicing, installing or cleaning.

 

 

z This must be done by the manufacturer or its service agent or a similar

 

qualified person in order to avoid a hazard.

 

 

INSTALLING THE UNIT

POWER SUPPLY LINE, FUSE OR CIRCUIT BREAKER

The unit should not be installed by the user. Ask the dealer or authorized company to install the units except room air conditioners for the U.S.A and Canada area.

If the unit is installed improperly, water leakage, electric shock or fire may result.

Mount with the lowest moving parts at least 2.5 m above the floor or grade level. (If applicable)

The manufacturer does not assume responsibility for accidents or injury caused by an incorrectly installed air conditioner. If you are unsure about installation, contact an installation specialist.

When installing the built-in type air conditioner, keep all electrical cables such as the power cable and the connection cord in pipe, ducts, cable channels e.t.c to protect them against liquids, outside impacts and so on.

If the power cord of this air conditioner is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.

The unit must be plugged into an independent circuit if applicable or connect the power cable to the auxiliary circuit breaker. An all pole disconnection from the power supply must be incorporated in the fixed wiring with a contact opening of >3mm.

Do not use an extension cord with this product.

If the unit is equipped with a power supply cord and a plug, the plug must be accessible after installation.

The air conditioner must be installed in accordance with national wiring regulations and safety regulations wherever applicable.

E-2

Contents

PREPARING THE INSTALLATION

 

Deciding on Where to Install the Air Conditioner ..........................................

4

Air Conditioner and Accessories ...................................................................

6

INSTALLING THE UNIT

 

Fixing the Installation Plate ...........................................................................

7

Purging the Unit.............................................................................................

7

Connecting the Assembly Cable ...................................................................

8

Installing and Connecting the Indoor Unit Drain Hose..................................

9

Installing and Connecting the Outdoor Unit Drain Hose...............................

9

Installing and Connecting the Indoor Unit Assembly Piping .........................

10

Cutting/Extending the Piping ........................................................................

11

COMPLETING THE INSTALLATION

 

Connecting Up and Purging the Circuit.........................................................

12

Performing Leak Tests...................................................................................

13

Placing the Indoor Unit in Position ................................................................

13

Fixing the Outdoor Unit in Position ...............................................................

14

Checking and Testing Operations .................................................................

14

Explaining Operations to the Owner .............................................................

15

E-3

PREPARING THE INSTALLATION

Deciding on Where to Install the Air Conditioner

When deciding on the location of the air conditioner with the owner, the following restrictions must be taken into account.

General

Do NOT install the air conditioner in a location where it will come into contact with the following elements:

Combustible gases

Saline air

Machine oil

Sulphide gas

Special environmental conditions

If you must install the unit in such conditions, first consult your dealer.

Indoor Unit

There must be no obstacles near the air inlet and outlet.

Install the indoor unit on a surface that can support its weight.

Choose a position that enables the piping and cables to be easily connected to the outdoor unit and the recommended length of 5 metres to be respected (15 metres maximum).

Leave enough clearance beneath the indoor unit to enable the filters to be removed without hindrance.

Maintain sufficient clearance around the indoor unit, as indicated in the diagram on the page opposite.

Make sure that the water dripping from the drain hose runs away correctly and safely.

Install the indoor unit on the wall which is far from the floor by more than 2.5 meters.

Outdoor Unit

The outdoor unit must NEVER be placed on its side or upside down, as the compressor lubrication oil will run into the cooling circuit and seriously damage the unit.

Choose a location that is dry and sunny, but not exposed to direct sunlight or strong winds.

Do not block any passageways or thoroughfares.

Choose a location where the noise of the air conditioner when running and the discharged air do not disturb any neighbours.

Choose a position that enables the piping and cables to be easily connected to the indoor unit and the recommended length of 5 metres to be respected (15 metres maximum).

Install the outdoor unit on a flat, stable surface that can support its weight and does not generate any unnecessary noise and vibration.

Position the outdoor unit so that the air flow is directed towards the outside, as indicated by the arrows on the top of the unit.

Maintain sufficient clearance around the outdoor unit, as indicated in the diagram on the page opposite.

If the outdoor unit is installed at a height, ensure that its base is firmly fixed in position; the maximum height is 7 metres.

Make sure that the water dripping from the drain hose runs away correctly and safely.

CAUTION

You have just purchased a split-type room air conditioner and it has been installed by your installation specialist.

This device must be installed according to the national electrical rules.

Max input power & current is measured according to IEC standard and input power & current is measured according to ISO standard.

E-4

Samsung AQ09XAN, AQ09XAX Manual

PREPARING THE INSTALLATION

Respect the clearances and maximum lengths indicated in the diagram below when installing the unit.

300 mm or more

Wrap the refrigerant pipes and the drain hose up in the absorbent pad and the vinyl tape, refer to page 13.

 

600 mm

 

minimum

 

15 metres

 

maximum

300 mm

300 mm

minimum

minimum

 

600 mm

 

minimum

 

300 mm or more

125 mm or more

This drain direction is selectable to left or right.