Samsung AM120JXVAGH/EU, AM JXVHGR Series, AM140JXVAGH/EU, AM160JXVAGH/EU, AM100JXVAGH Installation Manual

...
0 (0)
DVM S
AMJXVHGH Series AMJXVHGR Series AMHXVAGH Series AMJXVAGH Series
Air Conditioner
installation manual
imagine the possibilities
DVM S HE_IM_DB68-05461A-08_EN.indd 1 2017-03-24 오후 1:38:14
Contents
Safety precautions ..............................................................................................3
Preparing for installation ........................................................................................7
Selecting installation location...................................................................................24
Space requirement for installation ..............................................................................26
Accessories ....................................................................................................28
Base construction and installation of the outdoor unit............................................................29
Installing the wind/snow prevention duct .......................................................................34
Refrigerant pipe installation ....................................................................................36
Electrical wiring work ..........................................................................................68
Air tightness test and vacuum drying............................................................................86
Pipe insulation.................................................................................................88
Charging refrigerant............................................................................................92
Basic segment display ..........................................................................................95
Setting outdoor unit option switch and key function .............................................................95
Setting the MCU and Pipe Addresses (for HR Only) ..............................................................105
Things to check after completing the installation................................................................109
Inspection and test operation..................................................................................110
Automatic refrigerant amount detection function...............................................................116
For information on Samsung’s environmental commitments and product specic regulatory obligations e.g. REACH visit: samsung.com/uk/aboutsamsung/samsungelectronics/corporatecitizenship/data_corner.html
2
DVM S HE_IM_DB68-05461A-08_EN.indd 2 2017-03-24 오후 1:38:14
ENGLISH
Safety precautions
Please follow the following safety information for safety of the installer and the user.
DVM S air conditioner uses R-410A refrigerant.
• When using R-410A, moisture or foreign substances may aect the performance and reliability of the product. Safety precautions must be obeyed when installing the refrigerant pipe.
• The designed maximum pressure of the system is 4.1MPa and therefore select appropriate material and thickness according to the regulations.
• R-410A is a quasi-azeotrope of two refrigerants and it has to be charged in liquid phase when lling the refrigerant. (If you charge vapor refrigerant, it may change the blend of the refrigerant and cause product malfunction.)
You must connect the indoor units for R-410A refrigerant. Refer to product catalog to nd out the models
names for connectable indoor units. (If you connect the indoor units that are not designed for R-410A, it cannot operated normally.)
After completing the installation and trial operation, explain to the user how to use and maintain the product. Also,
hand over this installation manual so that it can be stored by the user.
Manufacturer is not responsible for the incidents occurred by improper installation. Installer is responsible for
any installation related claims from the user occurred by neglecting warnings and cautions stated in this manual. (Installer will be responsible for any service charges that may occur)
Generally, system air conditioners should not be relocated after installation. But when it has to be relocated for
inevitable reasons, please contact Samsung’s qualied dealers for system air conditioners.
WARNING
CAUTION
• Hazards or unsafe practices that may result in severe personal injury or death.
• Hazards or unsafe practices that may result in minor personal injury (to installer/user) or
property damage.
SEVERE WARNING SIGNS
Consult qualied installer or dealer for installation.
When installation is done by unqualied person, problems such as water leakage, electric shock or re may occur.
Installation work must be done properly according to this installation manual.
When installation is not done properly, it may cause water leakage, electric shock or re.
When installing the unit in a small room, take measure to keep the refrigerant concentration from exceeding allowable safety limits in case of refrigerant leakage. Consult the dealer for precautionary measure before the installation.
When refrigerant leaks and exceed dangerous concentration level, it may cause suocation accidents.
If any gas or impurities, except R-410A refrigerant, come into the refrigerant pipe, serious problem may occur and it may cause injury.
Use the supplied accessories, specied components and tools for the installation.
Do not use the pipe and the installation product used for the R-22 refrigerant.Failure to use the specied components can cause product fall down, water leakage, electrical shock, and re. (The
pipe and are components used for R-22 refrigerant must not be used)
Install the outdoor unit on a hard and even place that can support its weight.
If the place cannot support its weight, the outdoor unit may fall down and it may cause injury.
3
DVM S HE_IM_DB68-05461A-08_EN.indd 3 2017-03-24 오후 1:38:14
Safety precautions
Check the following before installation and service work.
Before welding, remove dangerous and inammable things that may cause an explosion and re around the work.Before welding, remove the refrigerant from inside the pipe or the product.
- If you perform welding while refrigerant is in the pipe, it may increase the pressure of the refrigerant and cause the pipe to burst. If the pipe bursts or explodes, it may cause severe injury to the installer.
When welding, use the nitrogen gas to eliminate oxidation inside the pipe.
Do not modify the product on your own.
Potential risk of electric shock, re, product failure or injury.
Fix the outdoor unit securely on foundation to resist strong wind or earthquake.
If the outdoor unit is not properly xed, it turns over and accidents may occur.
Electric work must be done by qualied persons, complying the national wiring regulations and installed according to the instruction stated in the installation manual with leased circuit.
Capacity shortage on the leased circuit and improper installation may cause electric shock or re.
Make sure to perform grounding work.
Do not connect the ground wire to a gas pipe, water pipe, lightning rod or telephone grounding. Improper
grounding could cause electric shock.
Wiring must be connected with the designated wires and it must be xed securely so that it does not apply any external force to the connection part of the terminals.
If connection for xation is not properly done, it may cause heat generation or re.
Neatly arrange the wires in the electrical parts to make sure that electrical cover is closed securely without any gaps.
If the cover is not properly closed, heat may generate on the electrical terminal and cause electric shock or re.
Exclusive circuit breaker (MCCB, ELB) must be installed to the power supply.
When overcurrent or current leakage occurs with no circuit breaker installed, power will not be cut-o and it may
cause electric shock or re.
Do not use damaged parts. It may cause re or electric shock.
You must cut-o the power before you work on, or adjust any power supply part for product installation, maintenance, repair or any other services.
There is risk of electric shock. Even when the power is o, it is dangerous when you come in contact with inverter PCB, fan PCB since high
pressure DC voltage is charged to those parts.
When replacing/repairing the PCB, cut-o the power and wait until the DC voltage is discharged before replacing/
repairing them. (Wait for more than 15 minutes to allow it to discharge naturally.)
If the refrigerant gas leaks during the installation, you should ventilate the room.
When the refrigerant gas gets in contact with ammable substance, it may generate toxic gas.
Gas leakage must be checked after installation is completed.
When the refrigerant gas gets in contact with ammable substance, it may generate toxic gas.
You can get a frostbite if you get in contact with the leaked refrigerant gas.
Supply power to the product during winter time since the product will operate in protection mode itself when the temperature decrease below 0°C.
If you cut-o the power, compressor protection mode cannot be operated and may cause damage to the product.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.Children should be supervised to ensure that they do not play with the appliance.
4
DVM S HE_IM_DB68-05461A-08_EN.indd 4 2017-03-24 오후 1:38:14
ENGLISH
For use in Europe : This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
CAUTION SIGNS
Do not install the drain pipe directly to the bottom part of the outdoor unit and built a proper drainage so that water drains out smoothly. If not, pipe may freeze or bursts during winter time and cause damage to the product or water leakage.
When the draining work is not done properly, water leak may occur and cause property damage.
Install the power cable and communication cable of the indoor and outdoor unit at least 1.5m away from the electric appliances and install it at least 2m away from the lightning conductor.
Noise may be generated from the electronic devices, depending on the status of the electric wave.
Install the outdoor unit within the angle stated in the table, according to the height of the building.
Do not leave the refrigerant container under the hot sunlight. (There is risk of explosion.)You must use the appropriate pipes according to the standard since the pressure of the refrigerant is very high.Make sure that the pipes does not get any weaker by welding it too much.Make sure to install the product away from children’s’ reach. (Sharp parts of the heat exchanger is may cause
personal injury and when parts of the product gets damage, it may decrease product’s performance.)
Lighting rod
Protective angle: 25˚~55˚
Height of the building Protection control
20m or less 55˚
40m or less 35˚
60m or less 25˚
Install the indoor unit away from lighting apparatus that uses ballast stabilizer.
If you use the wireless remote control, it may not operate normally due to ballast stabilizer.
Do not install the product in following places.
Place where outdoor unit’s noise and warm air may disturb neighbors. (It may cause property loss.)Do not leave any obstacles around the inlet and outlet of the product. (It may cause damage or accidents.)The place where there is mineral oil or arsenic acid.
- Those parts may get damaged due to burned resin and cause water leakage or product may fall.
- The eciency of the heat exchanger may reduce or product may break.
The place where corrosive gas such as sulfurous acid gas generates from the vent pipe or air outlet.
- The copper pipe or connection pipe may corrode and refrigerant may leak.
The place where there is a machine that generates electromagnetic waves.
- The air conditioner may not operate normally due to problems in control system.
The place where there is a danger of combustible gas leakage or place where thinner or gasoline is handled.
- (There is risk of re or explosion.)
The place with carbon ber or ammable dust.The place near seashore or hot spring where there is risk of outdoor unit corrosion.
5
DVM S HE_IM_DB68-05461A-08_EN.indd 5 2017-03-24 오후 1:38:14
Safety precautions
Changes in DVM S (inverter) compare to conventional models that has to noted when installing
For optimal distribution of the refrigerant, you must use Y-joint as branch joint for connecting outdoor units. (To
not use T-joint)
You cannot operate normally if you do not complete the trial operation through outdoor unit key mode. You must
use KEY MODE to run trial operation.
DVM S air conditioner uses R-410A refrigerant.Check the compatibility of other products such as indoor unit, EEV kits etc. which will be connected to DVM S.Make sure to note that outdoor unit combination is dierent from DVM PLUS III and IV.The length of maximum piping, level dierence, the quantity of connectable indoor units, the installation at the
outdoor joints and the outdoor unit combinations are dierent from the conventional models.
If the pipe length is over 2 m between outdoor units, make traps to prevent oil stagnation. Oil stagnation may
occur when outdoor unit at the end of module stops while other outdoor units are still in operation.
6
DVM S HE_IM_DB68-05461A-08_EN.indd 6 2017-03-24 오후 1:38:14
ENGLISH
Preparing for installation
Outdoor unit classication
Classication Small type Large type
Appearance
Models AM080/100/120XVG AM140/160/180/200/220/240/260XVG
Packaging material disposition
• Safely store or dispose the packaging materials.
CAUTION
- Sharp metals such as nails or wooden material packaging that may break into pieces become a cause for personal injury.
- Make sure to store or dispose the vinyl type packaging material to keep it out of reach of children. Children may put them over their face, which is very dangerous since it may lead them to suocation.
7
DVM S HE_IM_DB68-05461A-08_EN.indd 7 2017-03-24 오후 1:38:15
Preparing for installation
Outdoor unit combination
Make sure to use an indoor unit that is compatible with DVM S.Indoor units can be connected within the range indicated in following table.If the total capacity of the connected indoor units exceeds the indicated maximum capacity, cooling and heating
capacity of the indoor unit may decrease.
Total capacity of the connected indoor units can be allowed from 50% to 130% of the total outdoor unit capacity.
0.5 × Σ(Outdoor unit capacity) ≤ Total capacity of the connected indoor units ≤ 1.3 × Σ(Outdoor unit capacity)
You can connect maximum 64 indoor units to the outdoor unit. Maximum quantity of connectable indoor unit is
set to 64 since outdoor unit only support up to 64 communication address. Indoor unit address can be assigned from 0~63. If the indoor unit address was assigned from 64~79, E201 error will occur.
Maximum 32 Wall-mount type indoor units with EEV (AMFNQDEH, AMJNVDKH) can be connected.
• Use the following table to determine the size and number of outdoor units needed to achieve thecapacity requirements.
CAUTION
Standard type (Heat pump)
Model name for combination
Number of individual outdoor units
AM080JXVAGH AM100JXVAGH AM120JXVAGH AM140JXVAGH
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
AM160JXVAGH AM180JXVAGH AM200JXVAGH
AM220JXVAGH AM240HXVAGH AM260HXVAGH
Cooling (kW) Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM080JXVAGH/EU AM100JXVAGH/EU AM120JXVAGH/EU AM140JXVAGH/EU AM160JXVAGH/EU
1 1 1 1 1 1
1
1
1
1
22.4 28.0 33.6 40.0 45.0
25.2 31.5 37.8 45.0 50.4
11.2 14.0 16.8 20.0 22.5
29.1 36.4 43.7 52.0 58.5
14 18 21 26 29
8
DVM S HE_IM_DB68-05461A-08_EN.indd 8 2017-03-24 오후 1:38:15
ENGLISH
Model name for combination
Number of individual outdoor units
AM080JXVAGH
AM100JXVAGH
AM120JXVAGH
AM140JXVAGH
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
AM160JXVAGH
AM180JXVAGH
AM200JXVAGH
AM220JXVAGH AM240HXVAGH AM260HXVAGH
Cooling (kW) Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM180JXVAGH/EU AM200JXVAGH/EU AM220JXVAGH/EU AM240HXVAGH/EU AM260HXVAGH/EU
1 1 1 1 1
1
1
1
1
50.4 56.0 61.6 67.2 72.8
56.7 63.0 69.3 75.6 81.9
25.2 28.0 30.8 33.6 36.4
65.5 72.8 80.1 87.4 94.6
32 36 40 43 47
1
Model name for combination
Number of individual outdoor units
AM080JXVAGH
AM100JXVAGH
AM120JXVAGH
AM140JXVAGH
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
AM160JXVAGH
AM180JXVAGH
AM200JXVAGH
AM220JXVAGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM280JXVAGH1 AM300JXVAGH1 AM320JXVAGH1 AM340JXVAGH1 AM360JXVAGH1
2 2 2 2 2
1 1 1 1
1
1
1
1
1 1
78.6 84 89.6 95.2 101.6
88.2 94.5 100.8 107.1 114.3
39.3 42 44.8 47.6 50.8
102.2 109.2 116.5 123.8 132.1
51 54 58 61 64
9
DVM S HE_IM_DB68-05461A-08_EN.indd 9 2017-03-24 오후 1:38:15
Preparing for installation
Model name for combination
Number of individual outdoor units
AM080JXVAGH
AM100JXVAGH
AM120JXVAGH
AM140JXVAGH
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
Model name for combination
Number of individual outdoor units
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
AM160JXVAGH
AM180JXVAGH
AM200JXVAGH
AM220JXVAGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM080JXVAGH
AM100JXVAGH
AM120JXVAGH
AM140JXVAGH
AM160JXVAGH
AM180JXVAGH
AM200JXVAGH
AM220JXVAGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM380JXVAGH1 AM400JXVAGH1 AM420JXVAGH1 AM440JXVAGH1 AM460JXVAGH1
2 2 2 2 3
2
1
1
1
1 1 2 1
1
106.6 112.8 117.6 123.2 128.8
119.7 126.9 132.3 138.6 144.9
53.3 56.4 58.8 61.6 64.4
138.6 146.6 152.9 160.2 167.4
64 64 64 64 64
AM480JXVAGH1 AM500JXVAGH1 AM520JXVAGH1 AM540JXVAGH1 AM560JXVAGH1
3 3 3 3 3
1 1 1 1 1
1
1
1
1
1 1 1 1 2
135.2 140.2 145.6 151.2 156.8
152.1 157.5 163.8 170.1 176.4
67.6 70.1 72.8 75.6 78.4
175.8 182.3 189.3 196.6 203.8
64 64 64 64 64
10
DVM S HE_IM_DB68-05461A-08_EN.indd 10 2017-03-24 오후 1:38:15
ENGLISH
Model name for combination
Number of individual outdoor units
AM080JXVAGH
AM100JXVAGH
AM120JXVAGH
AM140JXVAGH
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
AM160JXVAGH
AM180JXVAGH
AM200JXVAGH
AM220JXVAGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM580JXVAGH1 AM600JXVAGH1 AM620JXVAGH1 AM660JXVAGH1 AM660JXVAGH1 AM680JXVAGH1
3 3 3 3 3 4
2
1
1
1
1
2 2 2 2 3 2
163.2 168.2 173.6 179.2 184.8 190.4
183.6 189 195.3 201.6 207.9 214.2
81.6 84.1 86.8 89.6 92.4 95.2
212.3 218.7 212.3 233 240.2 247.5
64 64 64 64 64 64
Model name for combination
Number of individual outdoor units
AM080JXVAGH
AM100JXVAGH
AM120JXVAGH
AM140JXVAGH
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
AM160JXVAGH
AM180JXVAGH
AM200JXVAGH
AM220JXVAGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM700JXVAGH1 AM720JXVAGH1 AM740JXVAGH1 AM760JXVAGH1 AM780JXVAGH1 AM800JXVAGH1
4 4 4 4 4 4
1 1 1 1 1
1 1
1
1
1
2 2 2 2 3 3
196.8 201.8 207.2 212.8 218.4 224.8
221.4 226.8 233.1 239.4 245.7 252.9
98.4 100.9 103.6 106.4 109.2 112.4
255.8 262.3 269.4 276.6 283.9 292.2
64 64 64 64 64 64
11
DVM S HE_IM_DB68-05461A-08_EN.indd 11 2017-03-24 오후 1:38:15
Preparing for installation
Standard Compact type (Heat pump)
Model name for combination AM360JXVAGH2 AM380JXVAGH2 AM460JXVAGH2 AM480JXVAGH2
Number of individual outdoor units
AM120FXVAGH
AM200FXVAGH
Combined outdoor unit
Rated capacity
Total capacity of the connected
indoor units (Cooling)
Maximum number of connectable indoor units
Model name for combination AM500JXVAGH2 AM520JXVAGH2 AM580JXVAGH2 AM600JXVAGH2
Number of individual outdoor units
Combined outdoor unit
Rated capacity
Total capacity of the connected
indoor units (Cooling)
Maximum number of connectable indoor units
AM220FXVAGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
AM120FXVAGH
AM200FXVAGH
AM220FXVAGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
2 2 2 2
1 1
1
1
1
1 1 1
100.8 106.4 128.8 134.4
113.4 119.7 144.9 151.2
50.4 53.2 64.4 67.2
131.0 138.3 167.4 174.7
64 64 64 64
2 2 3 3
1 1
1
1
1
1 2 1 1
140.0 145.6 162.4 168.0
157.5 163.8 182.7 189.0
70.0 72.8 81.2 84.0
182.0 189.3 211.1 218.4
64 64 64 64
12
DVM S HE_IM_DB68-05461A-08_EN.indd 12 2017-03-24 오후 1:38:15
ENGLISH
Model name for combination AM620JXVAGH2 AM640JXVAGH2 AM680JXVAGH2 AM700JXVAGH2
Number of individual outdoor units
AM120FXVAGH
AM200FXVAGH
Combined outdoor unit
Rated capacity
Total capacity of the connected
indoor units (Cooling)
Maximum number of connectable indoor units
Model name for combination AM720JXVAGH2 AM740JXVAGH2 AM760JXVAGH2 AM780JXVAGH2
Number of individual outdoor units
Combined outdoor unit
Rated capacity
Total capacity of the connected
indoor units (Cooling)
Maximum number of connectable indoor units
AM220FXVAGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
AM120FXVAGH
AM200FXVAGH
AM220FXVAGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
3 3 3 3
1 1
2 2
1 1
1 2 1
173.6 179.2 190.4 196.0
195.3 201.6 214.2 220.5
86.8 89.6 95.2 98.0
225.7 233.0 247.5 254.8
64 64 64 64
3 3 3 3
1 1
1 1
1 2 2 3
201.6 207.2 212.8 218.4
226.8 233.1 239.4 245.7
100.8 103.6 106.4 109.2
262.1 269.4 276.6 283.9
64 64 64 64
13
DVM S HE_IM_DB68-05461A-08_EN.indd 13 2017-03-24 오후 1:38:15
Preparing for installation
High EER type (Heat pump)
Model name for combination
Number of individual outdoor units
AM080JXVHGH
AM100JXVHGH
AM120JXVHGH
AM140JXVHGH
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
Model name for combination
Number of individual outdoor units
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
: Outdoor Unit Combination has been added.
AM160JXVHGH
AM180JXVHGH
AM200JXVHGH
AM220JXVHGH AM240HXVAGH AM260HXVAGH
Cooling (kW) Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM080JXVHGH
AM100JXVHGH
AM120JXVHGH
AM140JXVHGH
AM160JXVHGH
AM180JXVHGH
AM200JXVHGH
AM220JXVHGH AM240HXVAGH AM260HXVAGH
Cooling (kW) Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM080JXVHGH/EU AM100JXVHGH/EU AM120JXVHGH/EU AM140JXVHGH/EU AM160JXVHGH/EU
AM180JXVHGH/EU AM200JXVHGH/EU AM220JXVHGH/EU AM240HXVAGH/EU AM240JXVHGH1
1 1 1 1 1
1
1
1
1
1
22.4 28.0 33.6 40.0 45.0
25.2 31.5 37.8 45.0 50.4
11.2 14.0 16.8 20.0 22.5
29.1 36.4 43.7 52.0 58.5
14 18 21 26 29
1 1 1 1 2
2
1
1
1
1
50.4 56.0 61.6 67.2
56.7 63.0 69.3 75.6
25.2 28.0 30.8 33.6
65.5 72.8 80.1 87.4
32 36 40 43
14
DVM S HE_IM_DB68-05461A-08_EN.indd 14 2017-03-24 오후 1:38:15
ENGLISH
Model name for combination
Number of individual outdoor units
AM080JXVHGH
AM100JXVHGH
AM120JXVHGH
AM140JXVHGH
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
AM160JXVHGH
AM180JXVHGH
AM200JXVHGH
AM220JXVHGH AM240HXVAGH AM260HXVAGH
Cooling (kW) Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM260HXVAGH/EU AM260JXVHGH1AM280JXVHGH1 AM300JXVHGH1 AM320JXVHGH1
1 2 2 2 2
1 1 1 1
1
1
1
1
72.8 78.6 84 89.6
81.9 88.2 94.5 100.8
36.4 39.3 42 44.8
94.6 102.2 109.2 116.5
47 51 54 58
1
Model name for combination
Number of individual outdoor units
AM080JXVHGH
AM100JXVHGH
AM120JXVHGH
AM140JXVHGH
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
: Outdoor Unit Combination has been added.
AM160JXVHGH
AM180JXVHGH
AM200JXVHGH
AM220JXVHGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM340JXVHGH1 AM360JXVHGH1 AM380JXVHGH1 AM400JXVHGH1 AM400JXVHGH1
2 2 2 2 2
1
1 1
1
2
1 1 1
1
95.2 101.6 106.6 112.8
107.1 114.3 119.7 126.9
47.6 50.8 53.3 56.4
123.8 132.1 138.6 146.6
61 64 64 64
15
DVM S HE_IM_DB68-05461A-08_EN.indd 15 2017-03-24 오후 1:38:15
Preparing for installation
Model name for combination
Number of individual outdoor units
AM080JXVHGH
AM100JXVHGH
AM120JXVHGH
AM140JXVHGH
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
Model name for combination
Number of individual outdoor units
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
: Outdoor Unit Combination has been added.
AM160JXVHGH
AM180JXVHGH
AM200JXVHGH
AM220JXVHGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM080JXVHGH
AM100JXVHGH
AM120JXVHGH
AM140JXVHGH
AM160JXVHGH
AM180JXVHGH
AM200JXVHGH
AM220JXVHGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM420JXVHGH1 AM440JXVHGH1 AM460JXVHGH1 AM480JXVHGH1 AM500JXVHGH1
AM520JXVHGH1 AM540JXVHGH1 AM560JXVHGH1 AM580JXVHGH1 AM600JXVHGH1
2 2 3 3 3
2 1 1
1
1
1
1 2 1 1 1
117.6 123.2 128.8 135.2 140.2
132.3 138.6 144.9 152.1 157.5
58.8 61.6 64.4 67.6 70.1
152.9 160.2 167.4 175.8 182.3
64 64 64 64 64
3 3 3 3 3
1 1 1
1
1
1
1
1 1 2 2 2
145.6 151.2 156.8 163.2 168.2
163.8 170.1 176.4 183.6 189
72.8 75.6 78.4 81.6 84.1
189.3 196.6 203.8 212.3 218.7
64 64 64 64 64
16
DVM S HE_IM_DB68-05461A-08_EN.indd 16 2017-03-24 오후 1:38:16
ENGLISH
Model name for combination
Number of individual outdoor units
AM080JXVHGH
AM100JXVHGH
AM120JXVHGH
AM140JXVHGH
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
AM160JXVHGH
AM180JXVHGH
AM200JXVHGH
AM220JXVHGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM620JXVHGH1 AM660JXVHGH1 AM660JXVHGH1 AM680JXVHGH1 AM700JXVHGH1
3 3 3 4 4
2 1
1
2 1
1 2 3 2 2
173.6 179.2 184.8 190.4 196.8
195.3 201.6 207.9 214.2 221.4
86.8 89.6 92.4 95.2 98.4
212.3 233 240.2 247.5 255.8
64 64 64 64 64
Model name for combination
Number of individual outdoor units
AM080JXVHGH
AM100JXVHGH
AM120JXVHGH
AM140JXVHGH
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
AM160JXVHGH
AM180JXVHGH
AM200JXVHGH
AM220JXVHGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM720JXVHGH1 AM740JXVHGH1 AM760JXVHGH1 AM780JXVHGH1 AM800JXVHGH1
4 4 4 4 4
1 1 1 1
1
1
1
1
2 2 2 3 3
201.8 207.2 212.8 218.4 224.8
226.8 233.1 239.4 245.7 252.9
100.9 103.6 106.4 109.2 112.4
262.3 269.4 276.6 283.9 292.2
64 64 64 64 64
17
DVM S HE_IM_DB68-05461A-08_EN.indd 17 2017-03-24 오후 1:38:16
Preparing for installation
High EER Compact type (Heat pump)
Model name for combination AM360JXVHGH2 AM380JXVHGH2 AM460JXVHGH2 AM480JXVHGH2
Number of individual outdoor units
AM120JXVHGH
AM200JXVHGH
Combined outdoor unit
Rated capacity
Total capacity of the
connected indoor units
(Cooling)
Maximum number of connectable indoor units
Model name for combination AM500JXVHGH2 AM520JXVHGH2 AM580JXVHGH2 AM600JXVHGH2
Number of individual outdoor units
Combined outdoor unit
Rated capacity
Total capacity of the
connected indoor units
(Cooling)
Maximum number of connectable indoor units
AM220JXVHGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
AM120JXVHGH
AM200JXVHGH
AM220JXVHGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
2 2 2 2
1 1
1
1
1
1 1 1
100.8 106.4 128.8 134.4
113.4 119.7 144.9 151.2
50.4 53.2 64.4 67.2
131.0 138.3 167.4 174.7
64 64 64 64
2 2 3 3
1 1
1
1
1
1 2 1 1
140.0 145.6 162.4 168.0
157.5 163.8 182.7 189.0
70.0 72.8 81.2 84.0
182.0 189.3 211.1 218.4
64 64 64 64
18
DVM S HE_IM_DB68-05461A-08_EN.indd 18 2017-03-24 오후 1:38:16
ENGLISH
Model name for combination AM620JXVHGH2 AM640JXVHGH2 AM680JXVHGH2 AM700JXVHGH2
Number of individual outdoor units
AM120JXVHGH
AM200JXVHGH
Combined outdoor unit
Rated capacity
Total capacity of the
connected indoor units
(Cooling)
Maximum number of connectable indoor units
Model name for combination AM720JXVHGH2 AM740JXVHGH2 AM760JXVHGH2 AM780JXVHGH2
Number of individual outdoor units
Combined outdoor unit
Rated capacity
Total capacity of the
connected indoor units
(Cooling)
Maximum number of connectable indoor units
AM220JXVHGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
AM120JXVHGH
AM200JXVHGH
AM220JXVHGH
AM240HXVAGH
AM260HXVAGH
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
3 3 3 3
1 1
2 2
1 1
1 2 1
173.6 179.2 190.4 196.0
195.3 201.6 214.2 220.5
86.8 89.6 95.2 98.0
225.7 233.0 247.5 254.8
64 64 64 64
3 3 3 3
1 1
1 1
1 2 2 3
201.6 207.2 212.8 218.4
226.8 233.1 239.4 245.7
100.8 103.6 106.4 109.2
262.1 269.4 276.6 283.9
64 64 64 64
19
DVM S HE_IM_DB68-05461A-08_EN.indd 19 2017-03-24 오후 1:38:16
Preparing for installation
High EER type (Heat recovery)
Model name for combination
Number of individual outdoor units
AM080JXVHGR
AM100JXVHGR
AM120JXVHGR
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
Model name for combination
Number of individual outdoor units
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
AM140JXVHGR
AM160JXVHGR
AM180JXVHGR
AM200JXVHGR
AM220JXVHGR
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM080JXVHGR
AM100JXVHGR
AM120JXVHGR
AM140JXVHGR
AM160JXVHGR
AM180JXVHGR
AM200JXVHGR
AM220JXVHGR
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM080JXVHGR/EU AM100JXVHGR/EU AM120JXVHGR/EU AM140JXVHGR/EU AM160JXVHGR/EU
1 1 1 1 1
1
1
1
1
1
22.4 28.0 33.6 40.0 45.0
25.2 31.5 37.8 45.0 50.4
11.2 14.0 16.8 20.0 22.5
29.1 36.4 43.7 52.0 58.5
14 18 21 26 29
AM180JXVHGR/EU AM200JXVHGR/EU AM220JXVHGR/EU AM240JXVHGR1 AM260JXVHGR1
1 1 1 2 2
2 1
1
1
1
1
50.4 56 61.6 67.2 73.6
56.7 63 69.3 75.6 82.8
25.2 28 30.8 33.6 36.8
65.5 72.8 80.1 87.4 95.7
32 36 40 43 47
20
DVM S HE_IM_DB68-05461A-08_EN.indd 20 2017-03-24 오후 1:38:16
ENGLISH
Model name for combination
Number of individual outdoor units
AM080JXVHGR AM100JXVHGR AM120JXVHGR
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
AM140JXVHGR AM160JXVHGR AM180JXVHGR AM200JXVHGR AM220JXVHGR
Cooling (kW) Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM280JXVHGR1 AM300JXVHGR1 AM320JXVHGR1 AM340JXVHGR1 AM360JXVHGR1
2 2 2 2 2
1 1 1 1
1
1
1
1
1 1
78.6 84.0 89.6 95.2 101.6
88.2 94.5 100.8 107.1 114.3
39.3 42 44.8 47.6 50.8
102.2 109.2 116.5 123.8 132.1
51 54 58 61 64
Model name for combination
Number of individual outdoor units
AM080JXVHGR AM100JXVHGR AM120JXVHGR
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
Model name for combination
Number of individual outdoor units
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
AM140JXVHGR AM160JXVHGR AM180JXVHGR AM200JXVHGR AM220JXVHGR
Cooling (kW) Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM080JXVHGR AM100JXVHGR AM120JXVHGR AM140JXVHGR AM160JXVHGR AM180JXVHGR AM200JXVHGR AM220JXVHGR
Cooling (kW) Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM380JXVHGR1 AM400JXVHGR1 AM420JXVHGR1 AM440JXVHGR1 AM460JXVHGR1
2 2 2 2 3
2
1
2 1
1 1 2 1
106.6 112.0 117.6 123.2 128.8
119.7 126.0 132.3 138.6 144.9
53.3 56.4 58.8 61.6 64.4
138.6 146.6 152.9 160.2 167.4
64 64 64 64 64
AM480JXVHGR1 AM500JXVHGR1 AM520JXVHGR1 AM540JXVHGR1 AM560JXVHGR1
3 3 3 3 3
1 1 1 1 1 1
1
1
1
1 1 1 1 2
135.2 140.2 145.6 151.2 156.8
152.1 157.5 163.8 170.1 176.4
67.6 70.1 72.8 75.6 78.4
175.8 182.3 189.3 196.6 203.8
64 64 64 64 64
21
DVM S HE_IM_DB68-05461A-08_EN.indd 21 2017-03-24 오후 1:38:16
Preparing for installation
Model name for combination
Number of individual outdoor units
AM080JXVHGR
AM100JXVHGR
AM120JXVHGR
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
Model name for combination
Number of individual outdoor units
Combined outdoor
unit
Rated capacity
Total capacity of the
connected indoor
units (Cooling)
Maximum number of connectable
AM140JXVHGR
AM160JXVHGR
AM180JXVHGR
AM200JXVHGR
AM220JXVHGR
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM080JXVHGR
AM100JXVHGR
AM120JXVHGR
AM140JXVHGR
AM160JXVHGR
AM180JXVHGR
AM200JXVHGR
AM220JXVHGR
Cooling (kW)
Heating (kW)
Minimum (kW)
Maximum (kW)
indoor units
AM580JXVHGR1 AM600JXVHGR1 AM620JXVHGR1 AM660JXVHGR1 AM660JXVHGR1 AM680JXVHGR1
3 3 3 3 3 4
2
1
1
2 1
2 2 1 2 3 2
163.2 168.2 173.6 179.2 184.8 190.4
183.6 189.0 195.3 201.6 207.9 214.2
81.6 84.1 86.8 89.6 92.4 95.2
212.3 218.7 225.7 233 240.2 247.5
64 64 64 64 64 64
AM700JXVHGR1 AM720JXVHGR1 AM740JXVHGR1 AM760JXVHGR1 AM780JXVHGR1 AM800JXVHGR1
4 4 4 4 4 4
1 1 1 1 1
1 1
1
1
1
2 2 2 2 3 3
196.8 201.8 207.2 212.8 218.4 224.8
221.4 226.8 233.1 239.4 245.7 252.9
98.4 100.9 103.6 106.4 109.2 112.4
255.8 262.3 269.4 276.6 283.9 292.2
64 64 64 64 64 64
22
DVM S HE_IM_DB68-05461A-08_EN.indd 22 2017-03-24 오후 1:38:16
ENGLISH
Moving the outdoor unit
Select the moving path in advance.Be sure that moving path can support weight of the outdoor unit.Do not slant the product more than 30˚ when carrying it. (Do not lay the product down in sideways.)Surface of the heat exchanger is sharp. Be careful not to get injured while moving the product.
• You must use certain part of the product when moving the product.
CAUTION
When moving with a crane
Fasten the wire rope as shown in the gure.To protect damage or scratches, insert a piece of cloth between the
Wire rope
outdoor unit and the wire rope.
Holes for wire rope
to go through
When moving with a forklift
Carefully insert the forklift forks into the forklift holes at the bottom
of the outdoor unit.
Be careful with the forklift from damaging the product.
Forklift
Holes for forklift
forks to go
through
When moving the product without wooden pallet and the crane is not available for use
Connect a wire rope to the outdoor unit as you would move it with
a crane.
Hang the wire rope to the forklift fork to move the outdoor unit.
Forklift
Wire rope
Forklift holes
23
DVM S HE_IM_DB68-05461A-08_EN.indd 23 2017-03-24 오후 1:38:16
Selecting installation location
Decide the installation location, with the consideration of the following conditions, under user’s approval.
Place where hot discharge air or noise from the outdoor unit may not disturb the neighbor (Especially in residential
areas, keep the operation hours in mind.)
Place where structure can bear the weight and vibration of the outdoor unit.Place with at surface where rainwater does not settle or leak.Place where it is not exposed to strong wind.Well ventilated place with sucient service place for repairs and maintenance. (Discharge duct can be purchased
separately)
Place where you can connect the refrigerant pipes between indoor and outdoor units within allowable distance.Place where it allows easy waterproong and draining work for the condensation water generated from the
outdoor unit during heating operation.
Place where there is no risk of inammable gas leakage.Place where there is no direct inuence of snow or rain.Do not install the product in a place where it will be directly exposed to sea breeze.
- Consult an installation expert (or company) since you will need to take extra anti-corrosion measures if you need to install the product in a place where it can be exposed to direct sea breeze. (You have to remove dusts and salinity on the heat exchanger and apply designated rust inhibitor more than once a year.)
Outdoor
unit
Sea breeze
Sea
Outdoor
unit
Caution when installing the product in seashore
- When installing the product in seashore, make sure to install it behind a structure (such as building) that can block the sea breeze or install protection wall around the outdoor unit.
- Make sure to install the product in a place where it allows smooth drainage.
Protection wall
Sea
Sea breeze
Outdoor
unit
Sea
Protection wall should be constructed with a solid material that can block the sea breeze and the height and width of the wall should be 1.5 times larger than the size of the outdoor unit. (You must secure more than 700mm of space between the protection wall and the outdoor unit for air circulation.)
Sea breeze
Outdoor unit
Outdoor
unit
24
DVM S HE_IM_DB68-05461A-08_EN.indd 24 2017-03-24 오후 1:38:17
ENGLISH
• System air conditioner may cause static noise when listening to AM stations. Therefore, select an installation location for indoor unit where electrical wiring can be done while keeping certain distance
CAUTION
from a radio, computer and stereo equipment.
- Especially, keep the unit at least 3m away from the electrical equipment in an area with weak electromagnetic waves and put the main power cable and communication cables in a separately installed protection tube.
- Make sure that there is no equipment that generates electromagnetic waves. If not electromagnetic waves may cause problem to the control systems which may lead to air conditioner malfunction. (Example: Remote control sensor of the indoor unit may not receive the signal very well, due to ballast stabilizer of the lighting equipment.)
• In regions with heavy snowfall, make sure to install the outdoor unit where there is no concerns of direct snowfall on the outdoor unit. Also, build higher base support so that accumulated snow does not block the air inlet or the heat exchanger.
• R-410A refrigerant is a safe, nontoxic and nonammable refrigerant. However, if the place holds any concerns for exceeding dangerous level of refrigerant concentration in case of refrigerant leakage, extra ventilation system is required.
• When you install the outdoor unit in high places such as roof, install fence or guardrail around it. When there is no fence or guardrail, service person could fall.
• Do not install the product in places where corrosive gases such as sulfur oxides, ammonia, and sulfurous gas are produced. (e.g. Toilet outlet, ventilation opening, sewage works, dyeing complex, cattle shed, sulfuric hot spring, nuclear power plant, ship etc.) When installing the product in those places, contact an installation specialty store as the copper pipe and brazing part will need additional corrosion proof or anti­rust additive to prevent corrosion.
• Make sure to keep any inammable materials (such as wooden materials, oil etc.) around the outdoor unit. When there's re, those inammable material will easily catch the re and may pass it on to the product.
• Depending on the condition of power supply, unstable power or voltage any cause malfunction of the parts or control system. (At the ship or places using power supply from electric generator...etc)
• Make sure to install MCU when using HR products.
• When you select the location to install MCU, the location is far away from indoor rooms because the refrigerant running of MCU may create noise.
25
DVM S HE_IM_DB68-05461A-08_EN.indd 25 2017-03-24 오후 1:38:17
Space requirement for installation
Space requirement was decided based on following conditions; Cooling mode, outdoor temperature of 35°C.
Larger space is required if the outdoor temperature is higher than 35°C or if the place is heated easily by quantity of solar radiation.
When you secure installation space, consider path for people and the direction of the wind.Secure installation space as shown in the below illustration, considering ventilation and the service space. If the installation space is narrow, installer or other worker may get injured during work and may also cause
problem to the product.
If you install multiple number of outdoor units in one space, make sure to secure enough ventilation space if there’s
any walls around the product that may disturb the air ow. If enough ventilation space is not secured, product may malfunction.
You may install the outdoor units with 20mm of space between the product, but product’s performance may
decrease depending on the installation environment.
Single installation
(Unit : mm)
Over 300
Over 100 (S2)Over 500 (S1)
Front
Over 100 Over 100
Over 100
side
<Case 1> <Case 2>
Front side
Height of the wall is unlimited
26
DVM S HE_IM_DB68-05461A-08_EN.indd 26 2017-03-24 오후 1:38:17
ENGLISH
Module installation
Over 200
Over 300
Front
side
Over 400Over 400
Front side
Over 100
Over 100
<Case 1> <Case 2>
Over 100 Over 100 O ver 100 Over 100
Over 100
Front side
Over 100 O ver 100
Front side
Over 100
Over 100
Over 100
<Case 3>
(S2)
Over 300
(S1)
Over 500
Over 500Over 500 Over 600
For <Case 1> or <Case 3>
• Height of the wall on the front side should not be higher than 1500mm.
• Height of the wall on the air inlet side should not be higher than 500mm.
• Height of the wall on the side is not limited.
• If the height of the wall exceeds by certain value (h1, h2), additional clearance [(h1)/2, (h2)/2 : Half of the exceeded distance] should be added to the service space (S1, S2).
(Unit : mm)
Height of the wall is unlimited
Front side
1500 h1
S1+h1/2 S2+h2/2
Air inlet side
500 h2
27
DVM S HE_IM_DB68-05461A-08_EN.indd 27 2017-03-24 오후 1:38:17
Accessories
Accessories
You must keep following accessories until the installation is nished.Hand over the installation manual to the customer after nishing the installation.
Installation manual (1) Packing socket (1)
Models with packing socket : AM120/140XVGH, AM240/260XVAGH, AM180XVHGR.Socket can be dierent depending on the model.
Optional accessories
Following optional accessories are needed for connecting pipes between the indoor and outdoor units.
Classication Model Name Specication
MXJ-YA1509M 15.0kW and below
MXJ-YA2512M Over 15.0kW~40.0kW and below
MXJ-YA2812M Over 40.0kW~45.0kW and below
Y-Joint
Y-Joint (Only H/R)
Distribution header
Y-Joint
- Outdoor unit
Y-Joint (Only H/R)
- Outdoor unit
If you use an indoor unit with no internal EEV(Electric Expansion Valve), you will need an EEV kit.Only use the genuine accessories listed in above table and do not use imitated accessories.
MXJ-YA2815M Over 45.0kW~70.3kW and below
MXJ-YA3419M Over 70.3kW~98.4kW and below
MXJ-YA4119M Over 98.4kW~135.2kW and below
MXJ-YA4422M Over 135.2kW
MXJ-YA1500M 22.4kW and below
MXJ-YA2500M Over 22.4kW~70.3kW and below
MXJ-YA3100M Over 70.3kW~135.2kW and below
MXJ-YA3800M Over 135.2kW
MXJ-HA2512M 45.0kW and below (for 4 rooms)
MXJ-HA3115M 70.3kW and below (for 8 rooms)
MXJ-HA3819M Over 70.3kW ~ 135.2kW and below (for 8 rooms)
MXJ-TA3419M 135.2kW and below
MXJ-TA4122M Over 140.2kW
MXJ-TA3100M 135.2kW and below
MXJ-TA3800M 140.2kW and Over
28
DVM S HE_IM_DB68-05461A-08_EN.indd 28 2017-03-24 오후 1:38:17
ENGLISH
Base construction and installation of the outdoor unit
• Make sure to remove the wooden pallet before installing the outdoor unit. If you do not remove the wooden pallet, there is risk of re during welding the pipes. If the outdoor unit is installed with wooden
WARNING
pallet on, and it was used for long period time, wooden palette may break and cause electrical hazard or high pressure may damage the pipes.
Fix an outdoor unit rmly on the base ground with anchor bolts.Manufacturer is not responsible for the damage occurred by not following the installation standards.
1. Make sure that the height of the base ground is 200mm or higher to protect the outdoor unit from rain water or other external conditions. Also, install a draining pit around the base ground and connect the drain pipe to the drainage.
2. Considering the vibration and weight of the outdoor unit, strength of the base ground must be strong to prevent noise and the top surface of it should be at.
3. Base ground should be 1.5 times larger than the bottom of the outdoor unit.
4. Outdoor unit must be xed rmly so that it can withstand the wind speed of 30m/s. If you cannot x the outdoor unit on the base ground, x it by side or use extra structure.
5. In heating operation, defrost water may form so you must really care about the drainage and waterproong the oor. To prevent defrost water from stagnating or freezing, construct a drainage with over 1/50 slope. (Ice may form on the oor in winter season.)
6. It is necessary to add wire mesh or steel bar during concrete construction for the base ground to prevent damages or cracks.
7. When installing multiple outdoor units at the same place, construct a H beam or an anti-vibration frame on the base ground to install the outdoor unit.
8. After installing a H beam or an anti-vibration frame, apply corrosion protection and other necessary coating.
9. When concrete construction for outdoor unit installation is completed, install an anti-vibration pad (t=20mm or
more) or an anti-vibration frame to prevent vibration of the outdoor unit from transferring to the base ground.
10. Place the outdoor unit on a H beam or an anti-vibration frame and x it with the bolt, nut and washer. (The bearing
force has to be over 3.5kN)
Base ground construction
Bottom surface of the base ground must be horizontally
Draining pit
Over 200 mm
leveled
Over 200 mm
Over 200 mm
<When installing on the ground>
<When installing on the roof>
29
DVM S HE_IM_DB68-05461A-08_EN.indd 29 2017-03-24 오후 1:38:18
Base construction and installation of the outdoor unit
Outdoor unit installation
Base ground
Over 200 mm
H beam or anti­vibration frame
Over 200 mm
Outdoor unit base mount and anchor bolt position
A
B
54
54
Anti-vibration - Base ground (4-Ø 18)
Classication Small type Large type
Models AM080/100/120XVG AM140/160/180/200/220/240/260XVG
A 880 1,295
B 740 1,150
Refer to the blueprints in technical data book to make a holes for connecting the anti-vibration pad.
Outdoor unit - Anti-vibration frame (4-Ø 12)
761
803
Over 50 mm
(Unit : mm)
30
DVM S HE_IM_DB68-05461A-08_EN.indd 30 2017-03-24 오후 1:38:18