Pelco EC-4BY1SWUPOE-W, EC-4BY1SWCPOE-W, EC-3004CRPOE-W, EC-3004CLPOE-W, EC-3001URPOE-M Installation

...
0 (0)
Pelco EC-4BY1SWUPOE-W, EC-4BY1SWCPOE-W, EC-3004CRPOE-W, EC-3004CLPOE-W, EC-3001URPOE-M Installation

INSTALLATION AND OPERATION MANUAL

EC-4BY1SW Series

ETHERNETCONNECT 4-PORT SELF MANAGED POE+ SWITCH WITH EXTENDED UPLINK

This manual serves the following Model Number:

EC-4BY1SWCPOE-W

EC-4BY1SWUPOE-W

The EthernetConnect EC-4BY1SWxPOE-W is an Ethernet switch with uplink management functionality. It provides 4 copper ports operating at 10/100Mbps and is designed to combine these four electrical ports into a single electrical extended port that forwards this data to the next network device.

Ports 1–4 can supply up to thirty (30) watts of Power over Ethernet (PoE) and incorporate PoE+ features based on the IEEE 802.3at standard.

TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981

C3946M / REV 02-18-14

IMPORTANT SAFETY INSTRUCTIONS

1.Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not use this apparatus near water.

6.Clean only with dry cloth.

7.Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9.Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.

10.Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.

11.Only use attachments/accessories specified by the manufacturer.

12.Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

14.Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.

15.WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

16.Installation should be done only by qualified personnel and conform to all local codes.

17.Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.

18.Use only installation methods and materials capable of supporting four times the maximum specified load.

19.A CCC-approved power cord must be used to power this equipment when used in China.

20.CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.

The product and/or manual may bear the following marks:

This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.

This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

CAUTION:

RISK OF ELECTRIC SHOCK.

DO NOT OPEN.

TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981

C3946M / REV 02-18-14

INSTALLATION AND OPERATION MANUAL

EC-4BY1SW Series

 

 

APPLICATION DIAGRAM

Note: Coaxial applications use the EC-4BY1SWCPOE-W and EC-1501C-M; UTP applications use the EC-4BY1SWUPOE-W and EC-1501U-M.

Remote PoE Injection Mode

LOCAL

REMOTE

ETHERNET CONNECTION

EC-1501X-M

EC-4BY1SWXPOE-W

EXTENDED CONNECTION

 

 

PoE POWER

 

X

C (COAXIAL) OR U (UTP)

ETHERNET

SWITCH

POWER

POWER

Non-PoE Mode

POWER

LOCAL

REMOTE

EC-1501X-M

EC-4BY1SWXPOE-W

POWER

ETHERNET

SWITCH

POWER

POWER

POWER

POWER

IMPORTANT NOTE. PLEASE READ. The network implementations are shown as general representations only and are not intended to show detailed network topologies. Your actual network will differ, requiring changes or perhaps additional network equipment to accommodate the systems as illustrated. Please contact your local Pelco representative to discuss your specific requirements.

TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981

C3946M / REV 02-18-14

Loading...
+ 5 hidden pages