LDN127HV4
Multi F Ceiling Concealed Duct
12,000 Btu/h Indoor Unit
Performance:
Nominal Cooling Capacity (Btu/h) |
12,000 |
|
Nominal Heating Capacity (Btu/h) |
13,800 |
|
|
|
|
Cooling Nominal Test Conditions: |
Heating Nominal Test Conditions: |
|
Indoor: 80°F DB/67°F WB |
Indoor: |
70°F DB/60°F WB |
Outdoor: 95°F DB/75°F WB |
Outdoor: 47°F DB/43°F WB |
|
Electrical: |
|
|
Power Supply (V¹/Hz/Ø) |
|
208 230/60/1 |
Rated Amps (A) |
|
0.80 |
|
|
|
Pipe Connections: |
|
|
Liquid Line (in, OD) |
|
1/4 |
Vapor Line (in, OD) |
|
3/8 |
Drain OD, ID (in) |
|
1 1/4, 1 |
|
|
|
Features: |
|
|
•2 Thermistor control |
•Internal Condensate Pump |
|
•Auto opera on |
•Inverter (variable speed fan) |
|
•Auto restart |
•Group control |
|
•Control lock func on |
•Compatible with Single Zone ODU: |
|
|
LUU127HV4 |
|
Included Accessories:
•Simple Controller with Mode AKB72955816
Optional Accessories (sold separately
LG Programmable Thermostat PREMTB10U0
Simple Controller with Mode (Black) PQRCVCL0Q
Simple Controller with Mode (White) PQRCVCL0QW
Simple Controller without Mode (Black) PQRCHCA0Q
Simple Controller without Mode (White) PQRCHCA0QW
AC Smart IV PACS4B000
ACP IV PACP4B000
LonWorks Gateway PLNWKB100
BACnet Gateway PQNFB17C1
AC Ez PQCSZ250S0
Dry Contact Unit (1 contact, 24 VAC external power) PDRYCB100
Dry Contact Unit (2 input, power from indoor unit) PDRYCB400
Dry Contact for Third Party Thermostat PDRYCB300
For a complete list of available accessories, contact your LG representative.
Operating Range:
Cooling (°F WB) |
57 77 |
Heating (°F DB) |
59 81 |
Unit Data:
Refrigerant Type |
R410A |
Refrigerant Control |
EEV |
Sound Pressure² H/M/L (±3 dB(A)) |
31/28/27 |
Primary Filter |
Washable Pre filter |
Net Unit Weight (lbs) |
51 |
Shipping Weight (lbs) |
60 |
Fan:
Type |
|
Sirocco |
Quantity |
|
3 |
Motor/Drive |
Brushless Digitally Controlled/Direct |
|
Airflow Rate H/M/L (CFM) |
353/300/247 |
|
External Static Pressure³ (in wg) |
0.1 |
|
Minimum External Static Pressure |
0.0 |
|
Maximum External Static Pressure |
0.2 |
Notes:
1.Acceptable opera ng voltage: 187V 253V.
2.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996. 3.Adjust fan speed to correct for sta c pressure increases when using field supplied air filter. 4.At factory fan speed setting.
5.Air flow rate (CFM) at high speed.
6.See Engineering Manual for sensible and latent capaci es.
7.All power/communication cable to be minimum 18 American wire gage (AWG), 4 conductor, stranded, shielded or unshielded wire and must comply with applicable local and national code. If shielded, the wire must be grounded to the chassis at the outdoor unit only.
8.Power wiring cable size must comply with the applicable local and na onal code. 9.This unit comes with a dry helium charge.
10.Corresponding refrigerant piping length is in accordance with standard length of each outdoor unit and the level difference is 0 ft. All capacities are net with a combination ratio between 95 – 105%
11.Must follow installation instructions in the applicable LG installation manual.