LG LCE3610SB Installation Manual

0 (0)
Website: http://us.lgservice.com
MICROWAVE OVEN
INSTALLATION INSTRUCTIONS
PLEASE READ AND SAVE THESE INSTALLATION INSTRUCTIONS.
P/NO.: 3828W5U0529
2
Your Safety First
• Proper installation is the installer's responsibility!
– Read the entire manual before you begin. The model number label is located on the oven front.
See Figure 1. The mounting plate is located on back side of microwave oven. See Figure 2.
NOTE: Vent grille appearance varies by model.
BE SURE TO READ THE FOLLOWING SAFETY INSTRUCTIONS:
Model Number Plate
Mounting Plate
Figure 1 Figure 2
For Your Safety
WARNING
Label Cooking Guide
This oven should not be installed or located by anyone except properly qualified service personnel.
• You will need TWO people to install this oven. It is heavy and could cause personal injury if not handled properly.
• Avoid Electrical Shock!
– Before you drill into the wall, note where electrical outlets are and where electrical wires might be concealed
behind the wall. YOU COULD GET AN ELECTRIC SHOCK if you contact electrical wires with your drill bit.
– Locate and disconnect the power to any electrical circuits that could be affected by installing this oven.
IF YOU DO NOT DISCONNECT THE POWER, YOU COULD GET AN ELECTRIC SHOCK.
• ELECTRICAL RATING OF THIS OVEN : 120V AC 60Hz.
– You need a DEDICATED 120V, 60Hz, AC only, 15 or 20A, fused electrical supply (located in the cabinet
above the microwave as close as possible to the microwave) serving only the microwave.
3
Your Safety First
• THIS APPLIANCE MUST BE GROUNDED!
– If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape
wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug.
Place the plug into a properly installed and grounded outlet. See Figure 3.
Do not use an extension cord.
Keep the power cord dry and do not pinch or crush it.
• DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUNDING PRONG!
This appliance MUST be grounded!
Check with a qualified electrician if you are not sure whether the oven is properly grounded or if you do not completely understand the grounding instructions.
DO NOT USE A FUSE IN THE NEUTRAL OR GROUNDING CIRCUIT.
SAVE THESE INSTRUCTIONS FOR THE LOCAL ELECTRICAL INSPECTOR'S USE.
• DO NOT EXPOSE YOURSELF TO EXCESSIVE MICROWAVE ENERGY!
DO NOT try to operate the microwave oven with the door open. DO NOT tamper with or defeat the safety interlocks. DO NOT place objects between the microwave oven front face and the door. DO NOT allow soil or cleaner residue to build up on the flat surfaces around the microwave oven door. DO NOT operate the microwave oven if it is damaged. The microwave oven door must close properly to operate safely. DO NOT USE THE MICROWAVE OVEN:
If the door is bent.
If the hinges or latches are broken or loose.
If the door seals, sealing surfaces or glass is broken.
DO NOT ATTEMPT TO ADJUST OR REPAIR THE OVEN YOURSELF!
It should be adjusted and repaired by a qualified technician who can check for microwave leakage after repairing the oven.
PROPERLY POLARIZED AND
GROUNDED OUTLET
Three-Pronged (Grounding) Plug
Figure 3
If you use the grounding plug improperly, you risk electric shock and/or fire!
WARNING
Improper grounding could result in electric shock, fire or other personal injury.
WARNING
If you do not use the microwave oven as instructed,
you could be exposed to excessive microwave energy.
WARNING
4
Your Safety First
• MAKE SURE YOU HAVE ENOUGH SPACE AND SUPPORT.
– Mount the oven against a flat, vertical wall, so it is supported by the wall. The wall should be constructed of
minimum 2" x 4" wood studding and 3/8" thick drywall or plaster/lath.
ATTACH (See note on page 5) the two lag screws supporting the oven to a vertical, 2" x 4" wall stud. DO NOT mount the microwave oven to an island or peninsula cabinet. BE SURE the upper cabinet and rear wall structures can support 150 lbs., plus the weight of any
items you place inside the oven or upper cabinet.
Locate the oven away from strong draft areas, such as windows, doors, and strong heating vents. BE SURE you have enough space. See Figure 4 below for minimum vertical and horizontal clearance.
CAUTION
Before you begin installing the oven, PLACE A PIECE OF THE CARTON OR OTHER HEAVY MATERIAL (a blanket) over the countertop or cooktop to protect it. Do not use a plastic cover.
Failure to protect these surfaces could result in property damage.
30" min. cabinet opening width
30" min. clearance from bottom of cabinet to cooking surface or countertop before installation.
Grounded Outlet (inside upper cabinet)
Power Supply Cord Hole
(Use templates included with installation instructions)
Figure 4
If you do not mount the oven as instructed,
you risk personal injury and/or property damage.
WARNING
Parts, Tools, Materials
THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN:
NOTE: Depending on your ventilation requirements, you may not use all of these parts.
Damper/duct connector
(for roof venting or wall venting installation) Not Actual Size (2 pieces must be assembled as shown) Not used if venting into kitchen.
One power cord clamp and One dark-colored mounting screw
(to hold the power cord) Actual Size
One power cord clamp bushing - Actual Size (for the cord hole in a metal upper cabinet)
Four 1/4" x 2" lag screws - Actual Size
(for wall stud holes)
Two 1/4" x 3" bolts - Actual Size (for securing to the upper cabinet
Four 1/4" x 3" toggle bolts - Actual Size (for drywall holes)
Two tapping screws - Actual Size (for attaching the damper duct connector)
One upper cabinet template- Not Actual Size
Four 1/4" x 3" bolts - Actual Size (for securing to the upper cabinet)
One rear wall template- Not Actual Size (3 pieces mounting plate only)
NOTE: IT IS VERY IMPORTANT TO READ AND FOLLOW THE DIRECTIONS IN THE INSTALLATION INSTRUCTIONS BEFORE PROCEEDING WITH THIS REAR WALL TEMPLATE.
This template is for locating the wall venting cutout. Do not use this template for roof or room venting.
1.Place the template flat against the rear wall, aligning circles A and B with the corresponding holes previously drilled in the rear wall for holes A and B of the wall plate.
2.With the template aligned to the holes, tape the template to the rear wall.
3.Use a saber or keyhole saw to cut out the shaded area F through the rear wall.
A.
4.Remove the template from the rear wall.
RETURN TO AND PROCEED WITH THE
5.
LINE UP WITH
INSTALLATION INSTRUCTIONS. PREVIOUSLY DRILLED HOLE
Printed in Korea
P/N. 4922W5A060A
1/4
12
F. CUT OUT FOR WALL
4
VENTED ONLY
CUT HOLE THROUGH REAR WALL FOR EXHAUST ADAPTOR
CAUTION IF EXHAUST ADAPTOR IS POSITIONED OUTSIDE RECOMMENDED DIMENSION, GREASE LADEN AIR WILL
DISCHARGE INTO HOUSE STRUCTURE.
REAR WALL TEMPLATE
B.
LINE UP WITH PREVIOUSLY DRILLED HOLE
NOTE: You need to install at least two lag screws into a 2" x 4" stud and four anchor bolts into the wall.
and the mounting area must meet the 150 lbs. weight requirement.
– 5 –
6
Parts, Tools, Materials
Clear Tape
(for taping the templates to the wall)
Phillips Screwdriver
(for the screws)
Pencil
Flat Blade Screwdriver
(for the toggle bolts)
Plumb Line
Measuring Tape
(metal preferred)
Duct Tape
Small Side Cutters or Tin Snips
Caulking Gun and Caulk
Stud Finder or Thin Nail
Saber Saw (for cutting vent holes for roof or wall vending)
Keyhole Saw (for the power cord hole)
You will need the following tools and materials for the installation:
Carton or other heavy material such as a blanket for covering the counter top.
3/8" and 3/4" wood drill bits
1/2" and 3/16" drill bits
Electric Drill
If you have brick or masonry walls, you will need special hardware and tools.
The ductwork you need for the installation is not included. All wall and roof caps must have a back-draft damper.