LG HSN12IPX, HSN09IPX, HSN18IPX, HSN24IPX Owner’s Manual

5 (1)
www.lg.com
OWNER’S MANUAL
AIR CONDITIONER
Read this owner's manual thoroughly before operating the appliance and keep it handy for reference at all times.
TYPE: WALL MOUNTED
MFL69781206
Rev.00_012021
Copyright © 2021 LG Electronics Inc. All Rights Reserved
TABLE OF CONTENTS
SAFETY PRECAUTION ....................................................... 3
IMPORTANT SAFETY PRECAUTION ...................................................3
SAFETY INSTRUCTIONS ................................................... 5
IMPORTANT SAFETY INSTRUCTIONS ................................................6
OPERATION ....................................................................... 12
Notes for Operation ..............................................................................12
Parts and Functions .............................................................................. 12
Wireless Remote Control ...................................................................... 13
Restarting the Air Conditioner Automatically ........................................18
Using the Mode Function ...................................................................... 18
Using the Jet Mode Function ................................................................ 20
Using the Fan Speed Function ............................................................. 21
Using the Air Flow Direction Function ...................................................21
Setting the On/Off Timer ....................................................................... 22
Using the Sleep Function (Optional) ..................................................... 23
Using the Simple Timer Function (Optional) .........................................23
Using the Energy Display Function (Optional) ...................................... 24
Using the Light Off Function (Optional) ................................................24
Using the Comfort Air Function (Optional) ............................................24
Using the Energy Saving Function (Optional) ......................................25
Using the Energy Control Function (Optional) ...................................... 25
Using UVnano Function (Optional) ....................................................... 26
Using Special Functions ....................................................................... 27
This manual may contain images or content different from the model you purchased.
This manual is subject to revision by the manufacturer.
SMART FUNCTIONS ......................................................... 30
LG ThinQ Application ............................................................................ 30
Smart Diagnosis ...................................................................................32
MAINTENANCE .................................................................. 33
Clean the Air Filter ................................................................................35
Clean the Micro dust, Triple and Allergy Filter (Optional) .....................36
TROUBLESHOOTING ....................................................... 37
SAFETY PRECAUTION
IMPORTANT SAFETY PRECAUTION
Notes for Precaution
•The appliance shall be installed in accordance with national wiring regulations.
•Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules.
•This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
•If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified person in order to avoid a hazard.
•For more information on installation, please refer to the installation manual provided.
•The installation manual includes the following information.
− Instructions for safe use provided.
− Details concerning precautions during user maintenance.
− The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distance to adjacent structure.
− The method of connection and disconnection to the appliance to the electrical supply and interconnection of separate components.
− Details of type and rating of fuse, or rating of circuit breakers.
− Instruction for fixed appliances stating how the appliance is to be fixed.
•The service manual includes the following information.
− A wiring diagram with a clear indication of the connections and wiring to external control devices and supply cord.
EN
3
For R32
•The installation of pipe-work shall be kept to a minimum.
•Pipe-work shall be protected from physical damage.
•Compliance with national gas regulations shall be observed.
•Mechanical connections (mechanical connectors or flared joints) shall be accessible for maintenance purposes.
•Keep any required ventilation openings clear of obstruction.
•Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with an industry recognized assessment specification.
•Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants.
•The appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
•The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance) and ignition sources (for example an operating electric heater).
•The appliance shall be stored so as to prevent mechanical damage from occurring.
•For more information on installation, please refer to the installation manual provided.
•The installation manual includes the following information.
− The maximum refrigerant charge amount.
− Information for handling, installation, cleaning, servicing, and disposal of refrigerant.
•The service manual includes the following information.
− The minimum rated airflow.
EN
4
SAFETY INSTRUCTIONS
The following safety guidelines are intended to prevent unforeseen risks or damage from unsafe or incorrect operation of the appliance. The guidelines are separated into ‘WARNING’ and ‘CAUTION’ as described below.
This symbol is displayed to indicate matters and operations that can cause risk. Read the part with this symbol carefully and follow the instructions in order to avoid risk.
WARNING
This indicates that the failure to follow the instructions can cause serious injury or death.
CAUTION
This indicates that the failure to follow the instructions can cause the minor injury or damage to the product.
The following symbols are displayed on indoor and outdoor units.
EN
This symbol indicates that this appliance uses a flammable refrigerant. If the refrigerant is leaked and exposure to an external ignition source, there is a risk of fire.
This symbol indicates that the Operation Manual should be read carefully.
This symbol indicates that a service personnel should be handling this equipment with reference to the Installation Manual.
This symbol indicates that information is available such as the Operating Manual or Installation Manual.
5
IMPORTANT SAFETY INSTRUCTIONS
WARNING
To reduce the risk of explosion, fire, death, electric shock, injury or scalding to persons when using this product, follow basic precautions, including the following:
Installation
•Do not install the air conditioner on an unstable surface or in a place where there is danger of it falling.
•Contact an authorized service center when installing or relocating the air conditioner.
•Install the panel and the cover of the control box safely.
•Do not install the air conditioner in a place where flammable liquids or gases such as gasoline, propane, paint thinner, etc., are stored.
•Make sure that the pipe and the power cable connecting the indoor and outdoor units are not pulled too tight when installing the air conditioner.
•Use standard circuit breaker and fuse that conform to the rating of the air conditioner.
•Do not input air or gas into the system except with the specific refrigerant.
•Use non-flammable gas (nitrogen) to check for leak and to purge air; using compressed air or flammable gas may cause fire or explosion.
•The indoor/outdoor wiring connections must be secured tightly, and the cable should be routed properly so that there is no force pulling the cable from the connection terminals. Improper or loose connections can cause heat generation or fire.
•Install dedicated electric outlet and circuit breaker before using the air conditioner.
EN
6
•Do not connect the ground wire to a gas pipe, a lightning rod, or a telephone ground wire.
•Do not install the unit in potentially explosive atmospheres.
Operation
•Be sure to use only those parts listed in the service parts list. Never attempt to modify the equipment.
•Make sure that children do not climb on or hit the outdoor unit.
•Dispose of the batteries in a place where there is no danger of fire.
•Use only the refrigerant specified on the air conditioner label.
•Cut off the power supply if there is any noise, smell, or smoke coming from the air conditioner.
•Do not leave flammable substances such as gasoline, benzene, or thinner near the air conditioner.
•Contact an authorized service center when the air conditioner is submerged by flood waters.
•Do not use the air conditioner for an extended period of time in a small place without proper ventilation.
•In the event of a gas leak (such as Freon, propane gas, LP gas, etc.) ventilate sufficiently before using the air conditioner again.
•To clean the interior, contact an authorized service center or dealer. Using harsh detergents may cause corrosion or damage to the unit.
•Be sure to ventilate sufficiently when the air conditioner and a heating appliance such as a heater are used simultaneously.
•Do not block the inlet or outlet of air flow.
•Do not insert hands or other objects through the air inlet or outlet while the air conditioner is operating.
•Make sure that the power cable is neither dirty, loose, nor broken.
•Never touch, operate, or repair the air conditioner with wet hands.
EN
7
•Do not place any objects on the power cable.
•Do not place a heater or other heating appliances near the power cable.
•Do not modify or extend the power cable. Scratches or peeling insulation on the power cables may result in fire or electric shock, and should be replaced.
•Cut off the power supply immediately in the event of a blackout or a thunderstorm.
•Take care to ensure that power cable could not be pulled out or damaged during operation.
•Do not touch refrigerant pipe, water pipe and any internal parts while the unit is operating or immediately after operation.
Maintenance
•Do not clean the appliance by spraying water directly onto the product.
•Before cleaning or performing maintenance, disconnect the power supply and wait until the fan stops.
Technical Safety
•Installation or repairs made by unauthorized persons can pose hazards to you and others.
•The information contained in the manual is intended for use by a qualified service technician who is familiar with the safety procedures and equipped with the proper tools and test instruments.
EN
8
•Failure to read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death.
•When the power cord is to be replaced, the replacement work shall be performed by authorized personnel using only genuine replacement parts.
•This appliance must be properly grounded to minimize risk of electric shock.
•Do not cut or remove the grounding prong from the power plug.
•Attaching the earth wire to the power outlet cover screw does not ground the appliance unless the cover screw is metal, uninsulated, and the power outlet is grounded through house wiring.
•If you have any doubt whether the air conditioner is properly grounded, have the power outlet and circuit checked by a qualified electrician.
•The refrigerant and insulation blowing gas used in the appliance require special disposal procedures. Consult a service agent or a similarly qualified person before disposing of them.
•Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation. UV-C radiation may, even in little doses, cause harm to the eyes and skin.
•This appliance contains a UV-C lamp.
•When the appliances are damaged or need to replaced, disconnect the power supply and contact the service center.
•Do not operate UV-C lamp outside of the appliance.
•Do not clean and touch air deflector during operation.
•Before opening doors and access panels bearing the ultraviolet radiation hazard symbol for the conducting user maintenance, it is recommended to disconnect the power.
•Read the maintenance instructions before opening the appliance.
•Appliances that are obviously damaged must not be operated.
•The appliance must be disconnected from the supply before replacing the UV-C lamp.
EN
9
CAUTION
To reduce the risk of minor injury to persons, malfunction, or damage to the product or property when using this product, follow basic precautions, including the following:
Installation
•Do not install the air conditioner in an area where it is directly exposed to sea wind (salt spray).
•Install the drain hose properly for the smooth drainage of water condensation.
•Exercise caution when unpacking or installing the air conditioner.
•Do not touch the leaking refrigerant during installation or repair.
•Transport the air conditioner with two or more people or use a forklift.
•Install the outdoor unit such that it is protected from direct sunlight. Do not place the indoor unit in a place where it is directly exposed to sunlight via the windows.
•Safely dispose of packing materials such as screws, nails, plastic bag or batteries using proper packaging after installation or repair.
•Install the air conditioner in a place where the noise from the outdoor unit or the exhaust fumes will not inconvenience the neighbors. Failure to do so may result in conflict with the neighbors.
EN
Operation
•Remove the batteries if the remote control is not to be used for an extended period of time.
10
•Make sure that the filter is installed before operating the air conditioner.
•Be sure to check if there is a refrigerant leak after installing or repairing the air conditioner.
•Do not place any object on the air conditioner.
•Never mix different types of batteries, or old and new batteries for the remote control.
•Do not let the air conditioner run for a long time when humidity is very high or when a door or a window has been left open.
•Stop using the remote control if there is a fluid leak in the battery. If your clothes or skin are exposed to the leaking battery fluid, wash off with clean water.
•Do not expose people, animals, or plants to the cold or hot wind from the air conditioner for extended periods of time.
•If the leaking battery fluid has been swallowed, rinse the inside of the mouth thoroughly and consult a doctor.
•Do not drink the water drained from the air conditioner.
•Do not use the product for special purposes, such as preserving foods, works of art, and etc. It is an air conditioner for consumer purposes, not a precision refrigeration system. There is risk of damage or loss of property.
•Do not recharge or disassemble the batteries.
EN
Maintenance
•Never touch the metal parts of the air conditioner when removing the air filter.
•Use a sturdy stool or ladder when cleaning, maintaining, or repairing the air conditioner at a height.
•Never use strong cleaning agents or solvents when cleaning the air conditioner or spray water. Use a smooth cloth.
11
OPERATION
1
2
3
4
1
2
Notes for Operation
Suggestion for Energy Saving
• Do not over-cool the space. This may be harmful for your health and may consume more electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, within a short period of time.
• Open windows regularly for ventilation. The indoor air quality may deteriorate if the air conditioner is used for long durations.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or reduce the unit performance.
• For use in Australia, New Zealand : This air conditioner is capable of DRM1, DRM2 and DRM3 and complies with standard AS/NZS 4755.3.1.(Optional)
Parts and Functions
Indoor Unit Outdoor Unit
EN
Air Filter
Air Intake
Front Cover
Air Outlet
Air Deflector (Horizontal Vane)
5
Air Deflector (Vertical Louver)
6
On/Off Button
7
Air Intake Vents
Air Outlet Vents
NOTE
• The number and location of operation lamps may vary according to the model of the air conditioner.
• The feature may be changed according to the type of model.
12
EN
Swing
Wireless Remote Control
Inserting Batteries
If the display screen of the remote control begins to fade, replace the batteries. Insert AAA (1.5 V) batteries before using the remote control.
Remove the battery cover.
1
Insert the new batteries and make sure that
2
the + and - terminals of the batteries are installed correctly.
Installing the Remote Control Holder
To protect the remote control, install the holder where there is no direct sunlight.
Choose a safe and easily accessible
1
location.
Operating Method
Point the remote control towards the signal receiver at the right side of the air conditioner to operate it.
NOTE
• The remote control may operate other electronic devices if it is directed towards them. Make sure to point the remote control towards the air conditioner signal receiver.
• For proper operation, use a soft cloth to clean the signal transmitter and receiver.
• In case of a function not provided in the product, no buzzer sound occurs from the product when a button for such function on the remote control is pressed except for Air
Flow Direction ( Air Purification function (
), Energy Display ( ),
).
Fix the holder by fastening 2 screws firmly
2
with a screwdriver.
13
EN
ON/OFF
ON/OFF
Setting the Current Time
Insert batteries.
1
• The icon below blinks at the bottom of the display screen.
Press or button to select the
2
minutes.
Press Set/Cancel button to finish.
3
NOTE
• The On/Off Timer is available after setting the current time.
Using the °C/°F Conversion Function (Optional)
This function changes unit between °C and °F
• Press and hold
button about 5 seconds.
Operating the Air Conditioner without the Remote Control
You can use the ON/OFF button of the indoor unit to operate the air conditioner when the remote control is unavailable.
Open the front cover (Type2) or horizontal
1
vane (Type1).
Press the ON/OFF button.
2
Type1
Type2
NOTE
• The stepping motor may be broken, if the horizontal vane opens rapidly.
• The fan speed is set to high.
• The feature may be changed according to the type of model.
• The temperature cannot be altered when using this emergency ON/OFF button.
• For cooling-only models, the temperature is set to 22 °C
• For cooling & heating models, the temperature is set from 22 °C to 24 °C
14
Using Wireless Remote Control
Reset
Swing
Swing
You can operate the air conditioner more conveniently with the remote control.
EN
Button
2
Display
Screen
- To turn on/off the air conditioner.
Description
To adjust the desired room temperature in cooling, heating or auto changeover mode.
*
*
To select the cooling mode.
To select the heating mode.
*
1
Mode
To select the dehumidification mode.
To select the fan mode.
To select the auto changeover/auto operation mode.
Jet
Mode
Fan
Speed
To change room temperature quickly.
To adjust the fan speed.
To adjust the air flow direction vertically or horizontally.
NOTE
• * buttons may be changed according to the type of model.
15
Loading...
+ 33 hidden pages