LG HSNC1865NA4, HSNC1264NA8, HSNC2465NA4, HSNC1865NA8, S246JC Owner’s Manual

0 (0)
OWNER’S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating
your set and retain it for future reference.
P/NO : MFL30291720
www.lge.com
TYPE : WALL MOUNTED
*MFL30291720*
Ç
5
2 Room Air Conditioner
Room Air Conditioner Owner’s Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Write the model and serial numbers here:
Model #
Serial #
You can find them on a label on the side of each unit.
Dealer's Name
Date Purchased
Staple your receipt to this page in the event you need
it to prove date of purchase or for warranty issues.
READ THIS MANUAL
Inside you will find many helpful hints on how to use
and maintain your air conditioner properly. Just a little
preventive care on your part can save you a great deal
of time and money over the life of your air conditioner.
You'll find many answers to common problems in the
chart of troubleshooting tips. If you review our chart of
Troubleshooting Tips first, you may not need to call
for service at all.
PRECAUTION
Contact the authorized service technician for
repair or maintenance of this unit.
• Contact the installer for installation of this unit.
• The air conditioner is not intended for use by
young children or invalids without supervision.
• Young children should be supervised to ensure
that they do not play with the air conditioner.
• When the power cord is to be replaced,
replacement work shall be performed by
authorized personnel only using only genuine
replacement parts.
A. Safety Precautions ..............................3
B. Electrical Safety...................................6
Temporary Use of an Adapter ...............6
Temporary Use of an Extension Cord ...6
Symbols used in this Manual.................6
C. Operating Instructions........................7
Remote Controller..................................7
Wireless Remote Controller...................8
D. Maintenance and Service..................12
Indoor Unit...........................................12
Outdoor Unit ........................................12
Operation Tips!....................................13
Troubleshooting Tips............................14
Owner's Manual 3
Safety Precautions
ENGLISH
Safety Precautions
To prevent injury to the user or other people and property damage, the following instructions must be followed.
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by
the following indications.
Meanings of symbols used in this manual are as shown below.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage.
Be sure not to do.
Be sure to follow the instruction.
Always use a power plug and socket with
a ground terminal.
• There is a risk of electric shock.
Do not use a defective or underrated
circuit breaker. Use the correctly rated
breaker and fuse.
• There is risk of fire or electric shock .
Do not use a multi consent. Always use
this appliance on a dedicated cicuit and
breaker.
• Otherwise it can cause electric shock or fire.
For electrical work, contact the dealer, seller,
a qualified electrician, or an Authorized
Service Center. Do not disassemble or repair
the product by yourself.
• There is risk of fire or electric shock.
Always ground the product as per the
wiring diagram. Do not connect the
ground wire to gas or water pipes
lightening rod or telephone ground wire.
• There is risk of fire or electric shock.
Install the panel and the cover of control
box securely.
• There is risk of fire or electric shock due to
dust , water etc.
Use the correctly rated breaker or fuse.
• There is risk of fire or electric shock.
Do not modify or extend the power cable.
If the power cable or cord has scrathes or
skin peeled off or deteriorated then it
must be replaced.
• There is risk of fire or electric shock.
For installation, removal or reinstall ,
always contact the dealer or an
Authorized Service Center.
• There is risk of fire, electric shock, explosion,
or injury.
Do not install the product on a defective
installation stand. Be sure that the
installation area does not deteriorate with
age.
• It may cause product to fall.
Never install the outdoor unit on a
moving base or a place from where it
can fall down.
• The falling outdoor unit can cause damage or
injury or even death of a person.
When the product is soaked (flooded or
submerged) in water , contact an
Authorized Service Center for repair
before using it again.
• There is risk of fire or eletric shock.
In outdoor unit the step-up capacitor
supplies high voltage electricity to the
electrical components. Be sure to
discharge the capacitor completely
before conducting the repair work.
• An charged capacitor can cause electrical
shock.
When installing the unit, use the
installation kit provided with the product.
• Otherwise the unit may fall and cause severe
injury.
Be sure to use only those parts which
are listed in the svc parts list. Never
attempt to modify the equipment.
• The use of inappropriate parts can cause an
electrical shock, excessive heat generation or
fire.
4 Room Air Conditioner
Safety Precautions
Indoor/outdoor wiring connections must
be secured tightly and the cable should
be routed properly so that there is no
force pulling the cable from the
connection terminals.
• Improper or loose connections can cause
heat generation or fire.
Safely dispose off the packing materials.
Like screws, nails, batteries, broken
things etc after installation or svc and
then tear away and thraw away the plastic
packaging bags.
• Children may play with them and cause
injury.
Make sure to check that the power cable
plug is not dirty, loose or broken and
then only insert the plug completely.
• Dirty, loose or broken power plug can
cause electric shock or fire.
Be sure to check the refrigerant to the
used. Please read the label on the product.
• Incorrect refrigerant used can prevent the
normal operation of the unit.
Don't use a power cord, a plug or a loose
socket which is damaged.
• Otherwise it may cause a fire or electrical
shock.
Do not touch , operate, or repair the
product with wet hands. Hold the plug by
hand when taking out
• There is risk of electric shock or fire.
Do not place a heater or other heating
appliances near the power cable.
• There is risk of fire and electric shock.
Do not allow water to run into electric
parts. Install the unit away from water
sources.
• There is risk of fire, failure of the product, or
electric shock.
Do not store or use or even allow
flammable gas or combustibles near the
product.
• There is risk of fire.
Do not use the product in a tightly closed
space for a long time. Perform ventilation
regularly.
• Oxygen deficiency could occur and hence
harm your health.
Do not open the front grille of the product
during operation. (Do not touch the
electrostatic filter, if the unit is so equipped.)
• There is risk of physical injury, electric shock,
or product failure.
If strange sounds, smell or smoke comes
from product.Immediately turn the breaker
off or disconnect the power supply cable.
• There is risk of electric shock or fire.
Ventilate the product room from time to
time when operating it together with a
stove, or heating element etc.
• Oxygen deficiency can occur and hence harm
your health.
Turn the main power off and unplug the
unit when cleaning or repairing the
product.
• There is risk of electric shock.
When the product is not to be used for a
long time, disconnect the power supply
plug or turn off the breaker.
• There is risk of product damage or failure, or
unintended operation.
Take care to ensure that nobody
especially kids could step on or fall onto
the outdoor unit.
• This could result in personal injury and
product damage.
Take care to ensure that power cable
could not be pulled out or damaged
during operation.
• There is risk of fire or electric shock.
Do not place ANYTHING on the power
cable.
• There is risk of fire or electric shock.
Do not plug or unplug the power supply plug to turn the unit
ON/OFF .
• There is risk of fire or electric shock.
When flammable gas leaks, turn off the gas and open a window
for ventilation before turn the product on.
• Do not use the telephone or turn switches on or off. There is risk of
explosion or fire.
Two or more people must lift and
transport the product.
• Avoid personal injury.
Do not install the product where it will be
exposed to sea wind (salt spray) directly.
• It may cause corrosion on the product.
Install the drain hose to ensure that the
condensed water is drained away properly.
• A bad connection may cause water leakage.
Keep level even when installing the
product.
• To avoid vibration or noise.
Do not install the product where the noise
or hot air from the outdoor unit could
damage or disturb the neighborhoods.
• It may cause a problem for your neighbors
and hence dispute.
Always check for gas (refrigerant)
leakage after installation or repair of
product.
• Low refrigerant levels may cause failure of
product.
Owner's Manual 5
Safety Precautions
ENGLISH
Do not use the product for special purposes,
such as preserving foods, works of art, etc. It
is a consumer air conditioner, not a precision
refrigeration system.
• There is risk of damage or loss of property.
Do not block the inlet or outlet of air flow.
• It may cause product failure.
Use a soft cloth to clean. Do not use
harsh detergents, solvents or splashing
water etc .
• There is risk of fire, electric shock, or damage
to the plastic parts of the product.
Do not touch the metal parts of the
product when removing the air filter.
• There is risk of personal injury.
Do not step on or put anyting on the
product. (outdoor units)
• There is risk of personal injury and failure of
product.
Always insert the filter securely after
cleaning. Clean the filter every two weeks
or more often if necessary.
• A dirty filter reduces the efficiency.
Do not insert hands or other objects
through the air inlet or outlet while the
product is operating.
• There are sharp and moving parts that could
cause personal injury.
Be cautious when unpacking and
installing the product.
• Sharp edges could cause injury.
If the refrigerant gas leaks during the
repair, do not touch the leakaing
refrigerant gas.
• The refrigernat gas can cause frostbite (cold
burn)
Do not tilt the unit when removing or
uninstalling it.
• The condensed water inside can spill .
Do not mix air or gas other than the
specified refrigerant used in the system .
• If air enters the refrigerant system, an
excessively high pressure results, causing
equipment damage or injury.
If the refrigerant gas leaks during the
installation, ventilate the area immediately.
• Otherwise it can be harmfull for your health.
Dismantling the unit, treatment of the
refrigerant oil and eventual parts should
be done in accordance with local and
national standards.
Replace the all batteries in the remote
control with new ones of the same type.
Do not mix old and new batteries or
different types of batteries.
• There is risk of fire or product failure.
Do not recharge or disassemble the
batteries. Do not dispose off batteries in
a fire.
• They may burn or explode.
If the liquid from the batteries gets onto
your skin or clothes, wash it well with
clean water. Do not use the remote if the
batteries have leaked.
• The chemicals in batteries could cause burns
or other health hazards.
Do not let the air conditioner run for a
long time when the humidity is very high
and a door or a window is left open.
• Moisture may condense and wet or damage
furniture.
Do not expose your skin or kids or
plants to the cool or hot air draft.
• This could harm to your health.
Do not drink the water drained from the product.
• It is not sanitary and could cause serious health issues.
Use a firm stool or ladder when cleaning, maintaining or
repairing the product at an height.
• Be careful and avoid personal injury.
6 Room Air Conditioner
Electrical Safety
Electrical Safety
• This appliance must be properly grounded.
To minimize the risk of electric shock, you must alway plug into a grounded oulet.
• Do not cut or remove the grounding prong from the power plug.
• Attaching the adapter ground terminal to the wall receptacle cover screw does not ground the appliance
unless the cover screw is metal and not insulated, and the wall receptacle is grounded through the
house wiring.
• If you have any doubt whether the air conditioner is properly grounded, have the wall receptacle and
circuit checked by a qualified electrician.
We strongly discourage the use of an adapter due to potential safety hazards. For temporary connections,
use only a genuine adapter, available from most local hardware stores. Ensure that the large slot in the
adapter is aligned with the large slot in the receptacle for a proper polarity connection.
To disconnect the power cord from the adapter, use one hand on each to avoid damaging the ground
terminal. Avoid frequently unplugging the power cord as this can lead to eventual ground terminal damage.
• Never use the appliance with a broken adapter.
We strongly discourage the use of an extension cord due to potential safety hazards. For temporary
situations, use only CSA certified and UL listed 3-wire grounded extension cords, rated 15 A, 125 V.
Temporary Use of an Adapter
Temporary Use of an Extension Cord
This symbol alerts you to the risk of electric shock.
This symbol alerts you to hazards that may cause harm to the
air conditioner.
This symbol indicates special notes.
NOTE
Symbols used in this Manual
This appliance should be installed in accordance with national wiring regulations. This guide acts as a
guide to help to explain product features.
Remote Controller
Operating Instructions
Remove the battery cover by pulling it according to
the arrow direction.
Insert new batteries making sure that the (+) and (-)
of battery are installed correctly.
Reattach the cover by sliding it back into position.
Use 2 AAA(1.5volt) batteries. Do not use
rechargeable batteries.
NOTICE
• The remote control may be stored mounted on a wall. • To operate the room air conditioner, aim the remote
control at the signal receptor.
Storage and Tips For Using the Remote Control
Operating Instructions
Signal Receptor
Receives the signals from the remote controller.
(Signal receiving sound:two short beeps or one long beep.)
Operation Indication Lamps
On/O: Lights up during the system operation.
: Lights up during outdoor unit operation.
(Cooling model only)
Outdoor Unit
Operation
OUT
DOOR
Timer : Lights up during Timer operation.
Owner's Manual 7
ENGLISH
Wireless Remote Controller
The remote control transmits the signals to the system.
TEMP.
TIME
OFF
hr.
4
1
2
5
6
8
3
7
Cooling Operation
(Cooling Model)
Healthy Dehumidifacation Operation
TIME
OFF
hr.
TEMP.
1
3
2
4
OPERATION DISPLAY
Displays the operation conditions.
AIRFLOW DIRECTION BUTTON
Used to stop or start louver movement and
set the desired up/down airflow direction.
OPERATION MODE SELECTION
BUTTON
Used to select the operation mode.
OFF TIMER BUTTON
Used to set the time of stopping operation.
START/STOP BUTTON
Operation starts when this button is
pressed, and stops when the button is
pressed again.
ROOM TEMPERATURE SETTING
BUTTONS
INDOOR FAN SPEED SELECTION
BUTTON
JET COOL
Used to start or stop the speed cooling.
(Speed cooling operates super high fan
speed in cooling mode.)
1
2
3
4
5
6
7
8
(1) Operation Mode
(2) Operation Procedure
1st
2nd
3rd
4th
Start/Stop Button
Operation Mode Selection Button
Room Temperature Setting Button
Indoor Fan Speed Selection Button
8 Room Air Conditioner
Operating Instructions
TIME
OFF
hr.
TEMP.
TIME
OFF
hr.
TEMP.
TIME
OFF
hr.
TEMP.
To raise the temperature
To lower the temperature
TEMP.
TIME
OFF
hr.
TIME
OFF
hr.
TEMP.
Coo ling
Healthy
Dehumidification
Beep, Beep
Press the Start/Stop Button.
Select Cooling Operation.
Press the Operation Mode Selection Button.
Each time the button is pressed, the operation mode is shifted in the arrow direction.
Set the temperature lower than the room temperature.
• The temperature can be set within a range of 18°C ~ 30°C
by 1°C .
Set the fan speed.
Select the fan speed in four steps-low, medium, high
• Each time the button is pressed,
the fan speed mode is shifted.
The display shows high fan
speed.
Cooling Operation
1
2
3
4
Healthy Dehumidification Operation Mode
This mode dehumidifies
without overcooling.
During Healthy Dehumidification Operation:
If you select the dehumidification mode on the operation selection button, the airconditioner starts to run the
dehumidification function, automatically setting the room temp. and airflow volume to the best condition for
dehumidification based on the sensed current room temp.
In this case, however, the setting temp. is not displayed in the remote control and you are not able to control the
room temp. either.
During the healthy dehumidification function, the airflow volume is automatically set according to the
optimization algorithm responding to the current room temp. status and makes the room condition healthy and
comfortable even in the high humidity season.
Owner's Manual 9
Operating Instructions
ENGLISH
Beep, Beep
TIME
OFF
hr.
TEMP.
Press the OFF Time Button.
1. Press the OFF Time Button.
2. Check the OFF Time LED of the room air conditioner.
3. The Timer is programmed by 1 hour each
pressing the OFF Time button from 1 hour to 7 hours.
Timer control Setting
OFF TIMER CONTROL SETTING
Press the Jet Cool button to operate
the speed cooling mode and the unit
will operate at super high fan speed
on cooling mode for 30 minutes.
To cancel the
fan speed button or the room temperature setting button
again and the unit will operate at high fan speed on cooling
mode.
Jet Cool mode, press the Jet Cool button, the
TIME
OFF
hr.
TEMP.
Jet Cool Operation
10 Room Air Conditioner
Operating Instructions
Vertical Airow Direction Control
The up/down airow (Vertical Airow) can be adjusted
1. Press the Start/Stop button to start the unit.
2. Press Chaos Swing button and the louvers will swing
up and down. Press the Chaos Swing button again
to set the vertical louver at the desired airow
direction.
If you press the CHAOS swing button, the
horizontal airow direction is changed
automatically based on the CHAOS algorithm to
distribute the air in the room evenly and at the
same time to make the human body feel most
comfortable, as if enjoying a natural breeze.
Always use the remote control to adjust the
up/down airow direction. Manually moving the
vertical airow direction louver by hand, could
damage the air conditioner.
When the unit is shut o, the up/down airow
direction louver will close the air outlet vent of the
system.
NOTICE
Horizontal Airow Direction Control
• Adjust the horizontal airow direction by manually moving the
horizontal airow direction louver by hand.
Operation procedures when the remote control can't be used.
The operation will be started if the power button is pressed.
If you want to stop operation, re-press the button.
Forced Operation
Heat pump Model
Cooling
Model
Room Temp. 24°C 21 ° C Room Temp. < 24 °C
Room Temp. < 21 °C
Operating mode
Cooling Cooling
Healthy Dehumidication Heating
Indoor FAN Speed
High
High
High High
Setting Temperature
22° C
22° C
23° C
24° C
Test operation
During the TEST OPERATION, the unit operates in cooling mode at high speed fan, regardless of room
temperature and resets in 18 minutes.
During test operation, if remote controller signal is received, the unit operates as remote controller sets.
If you want to use this operation, open the front panel upward and Press the power button let it be pressed
for about 3 seconds.
If you want to stop the operation, re-press the button.
ON/OFF
button
ENGLISH
Owner's Manual 11
Operating Instructions
G
a
s
o
l
i
n
e
P
o
w
d
e
r
(Side)
(Rear)
Air intake
vents
Air outlet
vents
Piping
Drain Hose
Maintenance and Service
Indoor Unit
Outdoor Unit
CAUTION: Before performing any maintenance, turn o the main power to the system.
Grille, Case, and Remote Control
Turn the system o before cleaning. To clean, wipe
with a soft, dry cloth. Do not use bleach or
abrasives.
Supply power must be disconnected before cleaning
the indoor unit.
AIR FILTERS
The air lters behind the front grille should be checked
and cleaned once every 2 weeks or more often if
neccessary.
Never use any of the followings:
Water hotter than 40 °C
Could cause deformation and/or
discoloration.
Volatile substances
Could damage the surfaces of the air
conditioner.
Lift the front access panel and pull the lter tab
slightly forward to remove the lter.
Clean the lter with a vacuum or warm, soapy
water.
• If dirt is conspicuous, wash with a solution
of detergent in lukewarm water.
• If hot water (40 ° C or more) is used, it may
be deformed.
After washing with water, dry well in the shade.
Re-install the air lter.
NOTICE
The heat exchanger coils and panel vents of the outdoor unit
should be checked regularly. If clogged with dirt or soot, the
heat exchanger and panel vents may be professionally steam
cleaned.
Dirty or clogged coils will reduce the
operating eciency of the system and cause
higher operating costs.
NOTICE
Air inlet
Air filter
Air outlet
Front grille
ON/OFF button
Signal
receiver
Grille tab
Flap
(Horizontal blade)
Louvers
(Vertical blades)
12 Room Air Conditioner
Maintenance and Service
(Side)
(Rear)
Drain Hose
Air intake vents
Air outlet vents
Piping
(Side)
(Rear)
Piping
Drain Hose
Air intake
vents
Air outlet
vents
CAUTION
CAUTION
When the air conditioner is not going to be used for a long time.
Operation Tips
When air conditioner is not going to be
used for a long time.
When the air conditioner is to be used again.
Turn o the circuit breaker, and disconnect
the plug.
Remove the batteries from the remote
control.
Turn o the circuit breaker when the air conditioner
is not going to be used for a long time.
Dirt may collect and may cause a re.
Clean the air lter and install it in the indoor
unit.
(Refer to page 12 for cleaning lters.)
Check that the air inlet and outlet of the
indoor/outdoor unit are not blocked.
Do not overcool the room.
This is not good for the health
and wastes electricity.
Make sure that the doors
and windows are shut tight.
Avoid opening doors and
windows as much as possible
to keep the cool air in the room.
Keep blinds or curtains
closed.
Do not let direct sunshine enter
the room when the air
conditioner is in operation.
Clean the air lter regularly.
Blockages in the air lter
reduce the airow and lower
cooling and dehumidifying
eects. Clean at least once
every two weeks.
Keep the room temperature
uniform.
Adjust the vertical and
horizontal airow direction to
ensure a uniform temperature
in the room.
Ventilate the room
occasionally.
Since windows are kept closed,
it is a good idea to open them
and ventilate the room now and
then.
Owner's Manual 13
ENGLISH
Maintenance and Service
Loading...
+ 30 hidden pages