96M11891
Dome attachment
IV-D10
Instruction Manual
Read this manual before using the product in order to
achieve maximum performance.
Keep this manual in a safe place after reading it so that it
can be used at any time.
For details of functions, refer to the IV Series User's Manual
(Monitor) or the IV Series User's Manual (PC Software).
The IV Series User's Manual can be downloaded from the
y
KEYENCE web site:
http://www.keyence.com/
Symbols
The following symbols alert you to important messages.
Be sure to read these messages carefully.
It indicates a hazardous situation which, if not
avoided, will result in death or serious injury.
It indicates a hazardous situation which, if not
avoided, could result in death or serious injury.
It indicates a hazardous situation which, if not
avoided, could result in minor or moderate injury.
It indicates a situation which, if not avoided,
could result in product damage as well as
property damage.
It indicates cautions and limitations that must
be followed during operation.
It indicates additional information on proper
operation.
It indicates tips for better understanding or useful
information.
Cautions
(1) Unauthorized reproduction of this manual in whole or
part is prohibited.
(2) The contents of this manual may be changed for
improvements without prior notice.
(3)
An utmost effort has been made to ensure the contents of
this manual are as complete as possible. If there are any
mistakes or questions, please contact a KEYENCE ofce
listed in the back of the manual.
(4) Regardless of item (3), KEYENCE will not be liable for
any effect resulting from the use of this unit.
(5) Any manuals with missing pages or other paging faults
will be replaced.
The company names and product names used in this
manual are registered trademarks or the trademarks of their
respective companies.
Safety Information for IV series
General Precautions
Do not use this product for the purpose to
y
protect a human body or a part of human body.
This product is not intended for use as an
y
explosion-proof product. Do not use this
product in a hazardous location and/or
potentially explosive atmosphere.
You must verify that the IV Series are operating
y
correctly in terms of functionality and performance
before the start and the operation of the IV Series.
We recommend that you take substantial
y
safety measures to avoid any damage in the
event of a problem occurring.
KEYENCE never warrants the function or performance
y
of the IV Series if it is used in manner that differs from
the IV Series specications contained in this instruction
manual or if the IV Series are modied by yourself.
When the IV Series is used in combination with
y
other instruments, functions and performance
may be degraded, depending on operating
conditions and the surrounding environment.
Do not place the instruments, including
y
peripherals, under rapid temperature
change. It may cause condensation and may
damage instruments or peripherals.
Remove the power cable from the power supply
y
if you do not use this product for a long time.
Important Instructions
Observe the following precautions to prevent malfunction of
the IV Series and to ensure that it is used properly.
Precautions on use
For instructions
y
Do not turn OFF the power while setting the
y
items or saving the settings. Otherwise, all
or part of the setting data may be lost.
Do not let water, dust or oil stick to the
y
camera/light of the sensor. Failure to do so
may cause a malfunction.
When the this product becomes dirty, do not rub it
y
with a wet cloth, benzene, thinner, or alcohol. Doing
so may change the color or shape of the unit.
If the unit is heavily contaminated, disconnect
y
all the cables including the power supply cable,
wipe off the dirt with a cloth soaked with mild
detergent, and then wipe with a soft dry cloth.
Use the dome attachment at a proper
y
installation distance. Failure to do so may
lose the effect.
Adjust the brightness with the dome
y
attachment mounted.
For the color type, adjust the white balance
y
with the dome attachment mounted.
Measures to be taken when an abnormality occurs
In the following cases, turn the power OFF
immediately. Using the IV Series in an abnormal
condition could cause re, electric shock, or
malfunction. Contact our ofce for repair.
If water or debris enters the IV Series.
y
If the IV Series is dropped or the case is damaged.
y
If abnormal smoke or odor emanates from
y
the IV Series.
Precautions on installation
To use the this product correctly and safely, avoid
installing it in the following locations. Failure to do
so may cause re, electric shock, or malfunction.
Outdoors
y
Altitude above 2000 m
y
Locations that are humid, dusty or poorly ventilated
y
Locations where the temperature is high
y
such as those exposed to direct sunlight
Locations where there are ammable or
y
corrosive gases
Locations where the unit may be directly
y
subjected to vibration or impact
Locations where water, oil, or chemicals
y
may splash onto the unit
Checking the Package Contents
IV-D10
y
Mounting screw x 2
Dome attachment x 1
1
Hexagon wrench (L-shaped) x 1
Instruction Manual x 1 (This manual)
IV Series (Dome attachment) - IM_E
Mounting the attachment
Dome attachment can be used for the standard range type
and short range type sensor.
Do not remove the front cover of the sensor.
Mounting the dome attachment
Mount the attachment by aligning the concave
1
part of the dome attachment with the mounting
screw of the front cover of the sensor.
Screw hole for
mounting the
attachment
Front cover
mounting
screw
Concave
part
Fix the dome attachment with attached dedicated
2
screws.
yScrew : Dedicated screw x 2
Use attached dedicated screws.
Retightening torque : 0.25 to 0.35 N·m
y
Installed distance of the dome attachment
62 to 112 mm from the front face of the sensor
(0 to 50 mm from the front face of the dome attachment)
Sensor type
yStandard type
yShort range type
Installed distance from
the front face of the sensor
Concave
part
Specications
Model IV-D10
Compatible sensor
Installed distance
Standard type
Short range type
*
0 to 50 mm
Weight Approx. 15 g
* Distance from front side of dome attachment to the target.
Warranties and Disclaimers
(1) KEYENCE warrants the Products to be free of defects in materials and
workmanship for a period of one (1) year from the date of shipment. If any
models or samples were shown to Buyer, such models or samples were
used merely to illustrate the general type and quality of the Products and not
to represent that the Products would necessarily conform to said models or
samples. Any Products found to be defective must be shipped to KEYENCE
with all shipping costs paid by Buyer or offered to KEYENCE for inspection and
examination. Upon examination by KEYENCE, KEYENCE, at its sole option,
will refund the purchase price of, or repair or replace at no charge any Products
found to be defective. This warranty does not apply to any defects resulting from
any action of Buyer, including but not limited to improper installation, improper
interfacing, improper repair, unauthorized modication, misapplication and
mishandling, such as exposure to excessive current, heat, coldness, moisture,
vibration or outdoors air. Components which wear are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products.
They are only suggestions, and it is Buyer's responsibility to ascertain the
tness of the Products for Buyer’s intended use. KEYENCE will not be
responsible for any damages that may result from the use of the Products.
(3) The Products and any samples ("Products/Samples") supplied to Buyer are not
to be used internally in humans, for human transportation, as safety devices or
fail-safe systems, unless their written specications state otherwise. Should any
Products/Samples be used in such a manner or misused in any way, KEYENCE
assumes no responsibility, and additionally Buyer will indemnify KEYENCE and
hold KEYENCE harmless from any liability or damage whatsoever arising out of
any misuse of the Products/ Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE
PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS,
IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT
LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A
PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY
RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE
AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY
FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR
CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY
DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION,
LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS
OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF
SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY
MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR
INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS
AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S
CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some
jurisdictions, some of the foregoing warranty disclaimers or damage limitations
may not apply.
BUYER'S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by Buyer are to be resold or delivered to a
third party, Buyer must provide such third party with a copy of this document, all
specications, manuals, catalogs, leaets and written information provided to
Buyer pertaining to the Products/Samples.
62 to 112 mm
(0 to 50 mm)
Dimensions
Single dome attachment
φ134
When it is mounted on the sensor
φ134
62
Distance from WD reference surface
IV Series (Dome attachment) - IM_E
34.6
Target
Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved.
1121-1 96M11891 Printed in Japan
2