H
T-1 (3 mm) Diffused
LED Lamps
Technical Data
Features |
• Reliable and Rugged |
HLMP-130X Series HLMP-1385 HLMP-140X Series HLMP-1485 HLMP-1503 HLMP-1523 HLMP-1585 HLMP-K40X Series HLMP-K600
•High Intensity
•Choice of 4 Bright Colors
High Efficiency Red Orange
Yellow
High Performance Green
•Popular T-1 Diameter Package
•Selected Minimum Intensities
•Wide Viewing Angle
•General Purpose Leads
• Available on Tape and Reel
This family of T-1 lamps is widely used in general purpose indicator applications. Diffusants, tints, and optical design are balanced to yield superior light output and wide viewing angles. Several intensity choices are available in each color for increased design flexibility.
Part |
|
Minimum |
|
|
|
Number |
|
Intensity |
Color |
|
|
HLMP- |
Application |
(mcd) at 10 mA |
(Material) |
|
|
1300 |
General Purpose |
1.3 |
High Efficiency |
|
|
|
|
|
Red |
|
|
1301 |
General Purpose |
2.1 |
|
|
|
(GaAsP on |
|
|
|||
1302 |
High Ambient |
3.4 |
|
|
|
GaP) |
|
|
|||
|
|
|
|
|
|
1385 |
Premium Lamp |
8.6 |
|
|
|
|
|
|
|||
|
|
|
|
|
|
K400 |
General Purpose |
1.3 |
Orange |
|
|
|
|
|
(GaAsP on |
|
|
K401 |
High Ambient |
2.1 |
|
|
|
GaP) |
|
|
|||
|
|
|
|
|
|
K402 |
Premium Lamp |
3.4 |
|
|
|
|
|
|
|||
|
|
|
|
|
|
1400 |
General Purpose |
1.4 |
Yellow |
|
|
1401 |
General Purpose |
2.2 |
(GaAsP on |
|
|
GaP) |
|
|
|||
|
|
|
|
|
|
1402 |
High Ambient |
3.6 |
|
|
|
|
|
|
|||
1485 |
Premium Lamp |
5.7 |
|
|
|
|
|
|
|||
1503 |
General Purpose |
1.0 |
Green |
|
|
|
|
|
(GaP) |
|
|
1523 |
High Ambient |
2.6 |
|
|
|
|
|
|
|||
|
|
|
|
|
|
1585 |
Premium Lamp |
4.2 |
|
|
|
|
|
|
|||
K600[1] |
General Purpose |
1.0 |
Emerald Green |
|
|
|
|
|
(GaP) |
|
|
Note:
1.Please refer to Application Note 1061 for information comparing standard green and emerald green light output degradation.
1-134 |
5964-9374E |
Absolute Maximum Ratings at TA = 25°C
Parameter |
HER/Orange |
Yellow |
Green |
Units |
|
|
|
|
|
Peak Forward Current |
90 |
60 |
90 |
mA |
|
|
|
|
|
Average Forward Current[1] |
25 |
20 |
25 |
mA |
DC Current[2] |
30 |
20 |
30 |
mA |
Reverse Voltage (IR = 100 μA) |
5 |
5 |
5 |
V |
|
|
|
|
|
Transient Forward Current[4] |
500 |
500 |
500 |
mA |
(10 μsec Pulse) |
|
|
|
|
LED Junction Temperature |
110 |
110 |
110 |
°C |
Operating Temperature Range |
-55 to +100 |
-55 to +100 |
-20 to +100 |
°C |
|
|
|
|
|
Storage Temperature Range |
|
|
-55 to +100 |
|
|
|
|
|
|
Lead Soldering Temperature |
|
260°C for 5 seconds |
|
|
[1.6 mm (0.063 in.) from body] |
|
|
|
|
|
|
|
|
|
Notes:
1.See Figure 5 (HER/Orange), 10 (Yellow), or 15 (Green/Emerald Green) to establish pulsed operating conditions.
2.For Red, Orange, and Green series derate linearly from 50°C at 0.5 mA/°C. For Yellow series derate linearly from 50°C at 0.2 mA/°C.
3.For Red, Orange, and Green series derate power linearly from 25°C at 1.8 mW/°C. For Yellow series derate power linearly from 50°C at 1.6 mW/°C.
4.The transient peak current is the maximum non-recurring peak current that can be applied to the device without damaging the LED die and wirebond. It is not recommended that the device be operated at peak currents beyond the peak forward current listed in the Absolute Maximum Ratings.
Electrical Characteristics at TA = 25°C
|
|
Device |
|
|
|
|
Test |
Symbol |
Description |
HLMP- |
Min. |
Typ. |
Max. |
Units |
Conditions |
|
|
|
|
|
|
|
|
IV |
Luminous Intensity |
High Efficiency Red |
|
|
|
|
|
|
|
1300 |
1.3 |
5.0 |
|
mcd |
IF = 10 mA |
|
|
1301 |
2.1 |
5.5 |
|
|
|
|
|
1302 |
3.4 |
7.0 |
|
|
|
|
|
1385 |
8.6 |
11.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Orange |
|
|
|
|
|
|
|
K400 |
1.3 |
5.0 |
|
|
|
|
|
K401 |
2.1 |
5.5 |
|
|
|
|
|
K402 |
3.4 |
7.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Yellow |
|
|
|
|
|
|
|
1400 |
1.4 |
5.0 |
|
|
|
|
|
1401 |
2.2 |
6.0 |
|
|
|
|
|
1402 |
3.6 |
7.0 |
|
|
|
|
|
1485 |
5.7 |
10.0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Green |
|
|
|
|
|
|
|
1503 |
1.0 |
5.0 |
|
|
|
|
|
1523 |
2.6 |
7.0 |
|
|
|
|
|
1585 |
4.2 |
8.5 |
|
|
|
|
|
|
|
|
|
|
|
|
|
Emerald Green |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K600 |
1.0 |
4.5 |
|
|
|
|
|
|
|
|
|
|
|
1-135