0 (0)

ENO2-8C*B

Installation/Care/Use Manual

SwirlFlo® Refrigerated Fountains with FLEXI-GUARD®

38

37

Installer

To assure you install this model easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTINGTHE INSTALLATION. CHECKYOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

1/4" O.D. TUBE WATER INLET TO COOLER

FIG. 1

3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY

NOTE: WATER FLOW

DIRECTION

BUILDING WATER

INLET

SERVICE STOP (NOT FURNISHED)

FIG. 2

97112C (Rev. G - 10/01)

Elkay ENO2-8C-B Installation  Manual

10/01) - G .(Rev 97112C

2 PAGE

LEGEND

A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2" (38mm) OUT FROM WALL SHUT OFF BY OTHERS (BOTH SIDES)

B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4” O.D. DRAIN (BOTH SIDES)

C = 1-1/4 TRAP NOT FURNISHED

8C*B-ENO2

D = ELECTRICAL OUTLET LOCATION (RIGHT SIDE ONLY) * DIMENSIONS SHOWN ARE BASED ON 36" (914mm)

FLOOR TO BUBBLER ORIFICE HEIGHT. (WHEELCHAIR FOUNTAIN) CHECK LOCAL CODES.