Elkay 4405 FR FTN Installation Manual

5 (1)

4405 FR FTN

Owners Manual

Freeze Resistant Wall Mounted Tubular Fountain

Installer

 

4405FR Fountains are among the easiest to install Fountains on the market today. To assure you install

these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING

THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL,

AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future

reference. This Freeze Resistant Fountain is shipped in two separate cartons. The second carton(s)

contains the Freeze Resistant Package(s) HTFRB1 that are installed on an interior

heated wall. The

interior space must maintain a minimum temperature of 50° F (10° C). Refer to the

Freeze Resistant

Package for the rough-in dimensions for installation.

 

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON.

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

PAGE 1

97732C (Rev. J - 7/06)

Elkay 4405 FR FTN Installation  Manual

7/06) - J .(Rev 97732C

2 PAGE

FIG. 1

4405 FREEZE RESISTANT FOUNTAIN

 

MOUNTING BOLT AND ACCESS HOLE LAYOUT

FTN FR 4405

LEGEND

A = MOUNTING BOLT LOCATIONS (4)(1/2" DIA. NOT PROVIDED).

B = 7/8" DIA. (22mm) HOLE FOR WATER SUPPLY TUBE.

C = 7/8" DIA. (22mm) HOLE FOR OPERATING CABLE.

D = 2" DIA. (51mm) HOLE FOR WASTE LINE.