Installation and
Maintenance
Manual
COLUMN TAP
Table of Contents
Declaration of Conformity |
2 |
Before You Begin – |
|
Installing the Water Cooler and the |
|
|
Association |
2 |
Requirements for Installation |
7 |
Supply head |
11 |
|
Recommendations for Safeguarding the |
|
Mounting Dimensions |
7 |
Operating the Touch Control |
|
|
Environment |
3 |
Operating Environment |
8 |
Keypad Fontemagna Bridge Only |
16 |
|
Explanation of Warning/Safety Icons |
3 |
Water |
8 |
Programming the Touch Control |
18 |
|
Introduction |
4 |
Electrical |
8 |
Keypad Fontemagna Bridge Only |
||
Routine Maintenance |
19 |
|||||
Components Guide |
5 |
Tools You Will Need |
9 |
|||
Troubleshooting |
22 |
|||||
Product Specifications |
6 |
Unpacking the Kit |
9 |
|||
Replacement Parts |
25 |
|||||
|
|
What’s in the Kit |
10 |
|||
|
|
|
|
NOTICE: Read the instructions in this manual and retain for future reference.
Carbonation Chiller, Fontemagna Bridge and Column Tap
Installation and Maintenance Manual
Declaration of Conformity
D.M. 174
Materials compliant for contact with drinking water
This unit is intended for the dispensing of drinking water, and so the materials that enter into direct contact with water meet the criteria for food-grade components pursuant to the current legislation. In addition, the unit is manufactured in compliance with Italian Ministerial Decrees 174 of 04/06/2004 and 25 of 02/07/2012.
Electrical safety
This water cooler is designed, manufactured and marketed in compliance with:
ΟΟthe safety objectives of the Low Voltage Directive 2006/95/EC;
ΟΟthe protection requirements of the Electromagnetic Compatibility Directive 2004/108/EC.
The electrical safety of the product is ensured only when it is properly connected to an efficient, legally compliant grounding circuit.
UL standard for safety of drinking water coolers, ANSI/UL 399, Issued: 2008/08/22, Ed: 7, Rev: 2013/10/18 and UL 60335-1
CSA standard for refrigeration equipment, CSA Column Tap2.2 No. 120, Issued: 2013/03/01, Ed: 4 and CAN/
CSA Column Tap2.2 No. 60335-1
Association
International Awards
2014 – BEST PROMOTION OF HEALTH AND HYDRATION
EUROPEAN AQUA AWARDS 2014, BUDAPEST
2013 – BEST PRODUCT INNOVATION
EUROPEAN AQUA AWARDS 2013, BERLIN
2012 – BEST ENVIRONMENTALLY FRIENDLY PRACTICE
EUROPEAN AQUA AWARDS 2012, ISTANBUL
2011 – BEST PRODUCT DESIGN/INNOVATION
EUROPEAN AQUA AWARDS 2011, ODESSA
2010 – BEST ENVIRONMENTALLY FRIENDLY PRACTICE
EUROPEAN AQUA AWARD 2010, PRAGUE
2
RecommendationsforSafeguardingtheEnvironment
Packaging materials
The packaging materials are 100% recyclable. Please follow the local guidelines on waste disposal.
For safety reasons keep the packaging material out of the reach and sight of children.
Scrappage
The Carbonation Chiller water cooler, Fontemagna Bridge and Column Tap supply head are made using recyclable material.
These units are marked in compliance with European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). By ensuring that the product is scrapped correctly, you will help to prevent potential negative consequences for the environment and for health. This symbol indicates that the product should not be treated as domestic waste but should be taken to a dedicated recycling center for electrical and electronic equipment. Immediately prior to scrapping, cut off the power cable.
For more information on the treatment, recovery and recycling of this product, please contact the appropriate local office, the waste disposal service or the reseller from which the product was purchased.
Explanation of Warning/Safety Icons
NOTICE: Indicates an instruction which, if not followed, could result in damage to product or property or poor product performance.
CAUTION: Indicates an instruction which, if not followed, could result in minor or moderate injury.
WARNING:Indicates an instruction which, if not followed, could result in serious injury or death.
1000002475 (Rev. C - 07/2015) |
3 |
Carbonation Chiller, Fontemagna Bridge and Column Tap
Installation and Maintenance Manual
Introduction
The Carbonation Chiller water cooler, Fontemagna Bridge and Column Tap supply head bring contemporary style and state-of-the-art technology to commercial water dispensers. Carbonation Chiller undercounter water cooler can be used with either Fontemagna Bridge or Column Tap, combining professional performances with a modern, sleek design.
ΟΟMultiple dispensing options: cold still water, cold sparkling water, and room-temperature still water
ΟΟNatural materials throughout: stainless steel, aluminum, glass
ΟΟInternal components made entirely of stainless steel
Carbonation Chiller
ΟΟCooling serpentine coil made with the best stainless steel for drinkable water - AISI 316
ΟΟHigh-insulation ice bank ensures a high output of cold water, still and sparkling
Fontemagna Bridge
ΟΟElectronic keypad with glass cover, easy to use and hygienic, with touch control commands
ΟΟPreprogrammed quantities of water to minimize overflow and waste
ΟΟEnergy Saving command: when selected, this feature enables standby functionality of the unit, with consumption reduced by 75% compared to full functionality
ΟΟBactericidial UV lamp at exit of each tap
Column Tap
ΟΟSelf closing tap to avoid accidental water leakage
ΟΟCompensator included to regulate the flow of each spout
NOTICE: Due to rigorous testing, product may reasonably be expected to contain traces of sanitizing solution.
4
Components Guide
Carbonation Chiller |
Fontemagna Bridge |
Column Tap |
|
Sparkling water |
Room temperture |
|
Compensator |
water outlet |
|
||
outlet |
Cold water outlet |
|
|
|
|
||
|
|
Sparkling water |
|
|
|
|
nozzle |
Power button |
|
Touch Control |
|
|
|
|
|
Thermostat |
|
keypad |
Cold water nozzle |
|
|
||
|
|
|
|
Ice bank inlet |
|
|
|
CO2 inlet |
|
|
|
Ice bank overflow |
|
Drip tray |
|
Water inlet |
|
|
|
Ice bank level
|
Sparkling water |
Sparkling water |
|
inlet |
|
|
inlet |
|
|
Room temperture |
Cold water inlet |
|
water inlet |
|
Power cable |
Cold water inlet |
Power cable |
|
|
Dispensing buttons – |
|
small serving |
|
large serving |
Power |
|
button |
Fontemagna Bridge
Touch Control keypad
Energy
Saving
button
Cold |
Cold still |
sparkling |
dispenser |
dispenser |
|
Room-temperature
still dispenser
1000002475 (Rev. C - 07/2015) |
5 |
Carbonation Chiller, Fontemagna Bridge and Column Tap
Installation and Maintenance Manual
Product Specifications
|
Specification |
Carbonation Chiller |
Fontemagna Bridge |
Column Tap |
|
|
Cooling capacity gal/h (lt/h) |
20 (80) |
|
|
|
|
|
|
|
|
|
|
Continuous supply gal (lt) |
12 (45) |
|
|
|
|
|
|
|
|
|
|
Cold water temperature |
37.4°F – 50°F |
|
|
|
|
|
(3°C – 10°C) |
|
|
|
|
Ice bank capacity gal (lt) |
3.7 (14) |
|
|
|
|
|
|
|
|
|
|
Ice bank lb (kg) |
11 (5) |
|
|
|
|
|
|
|
|
|
|
Cooling technology |
ICE BANK single stainless |
|
|
|
|
|
steel coil |
|
|
|
|
Condensation |
Forced ventilation (fan) |
|
|
|
|
|
|
|
|
|
|
Adjustable thermostat |
Yes |
|
|
|
|
|
|
|
|
|
|
Refrigerant gas |
R134a |
|
|
|
|
|
|
|
|
|
|
Compressor |
1/6 HP |
|
|
|
|
|
|
|
|
|
|
Pump |
Professional carbonator |
|
|
|
|
|
pump |
|
|
|
|
Inlet water pipe |
ø 3/8" |
ø 3/8" |
ø 3/8” |
|
|
|
|
|
|
|
|
Supply |
115V - 60Hz |
115V - 60Hz |
|
|
|
|
(230V - 50Hz) |
(230V - 50Hz) |
|
|
|
Power |
330W - 3.2A |
50W - 0.44 A |
|
|
|
|
|
|
|
|
|
Working room temperature |
Min 41°F – Max 107.6°F |
Min 41°F – Max 107.6°F |
|
|
|
|
(Min 5°C – Max 42°C) |
(Min 5°C – Max 42°C) |
|
|
|
UNIT WEIGHT lb (kg) |
59 |
33 |
9 |
|
|
|
(27) |
(15) |
(4) |
|
|
SHIPPING WEIGHT lb (kg) |
66 |
35 |
11 |
|
|
|
(30) |
(16) |
(5) |
|
|
|
|
|
|
|
|
Dimensions W x D x H in (mm) |
12.5 x 18.4 x 18.6 |
14.2 x 10.2 x 23.8 |
5.2 x 9.1 x 18.7 |
|
|
|
(317 x 467 x 472) |
(361 x 290 x 605) |
(132 x 231 x 475) |
|
|
Dispensingareaheightin (mm) |
|
12 |
12 |
|
|
|
|
(305) |
(305) |
|
|
Packaging dimensions in (mm) |
16.5 x 23.2 x 28.3 |
16.1 x 30.5 x 12.0 |
6.7 x 6.7 x 28.3 |
|
|
|
(420 x 590 x 720) |
(410 x 775 x 305) |
(170 x 170 x 720) |
|
|
Dispensing |
3 supply option |
3 supply option (sparkling, |
2 supply option (sparkling |
|
|
|
(sparkling, cold and |
cold and room temperature |
and cold water) |
|
|
|
room temperature |
water) with customizable |
|
|
|
|
water) |
portion control system |
|
|
|
|
|
|
|
|
|
Mechanical outlet taps |
|
|
HQ stainless steel |
|
|
|
|
|
|
|
|
Push buttons |
|
Electronic touch screen |
|
|
|
|
|
board |
|
|
|
Energy Saving device |
|
Included, dedicated push |
|
|
|
|
|
buttons |
|
|
|
Materials |
All robust stainless steel |
All robust stainless steel, |
Stainless steel (water supply |
|
|
|
parts |
aluminium and glass |
path) and nickel brass |
|
|
|
|
|
(body) |
|
6
Before You Begin – Requirements for Installation
Mounting Dimensions (Carbonation Chiller only)
Under counter (includes 4" clearance on sides and back)
Depth 24.6" (625mm)
Footprint: 12.5" x 18.4" 317mm x 467mm
Depth 3.88" (99mm)
Height:
12.75"
(324mm)
Width 3.25" (83mm)
Height: 28" (711mm)
Water filter
Width 20.5"(520mm)
Height 26.6" (675mm)
Diameter 8" (203mm)
CO2 cylinder (typical, 20 pound)
1000002475 (Rev. C - 07/2015) |
7 |
Carbonation Chiller, Fontemagna Bridge and Column Tap
Installation and Maintenance Manual
Operating Environment
ΟΟInstall the machine in a clean, dry, well-ventilated room. It is designed to function correctly in environments with a temperature of 16°C to 32°C – Climatic Class N, (between 61°F and 90°F).
ΟΟCheck that the water cooler is level, that it is on a surface that can support its weight and in an environment suitable for its size and use.
ΟΟDo not place the machine near a source of heat.
ΟΟTo guarantee adequate ventilation, leave at least 6" (152 mm) of space around the unit.
ΟΟTake care not to damage the cooling fluid circuit: Carbonation Chiller is filled with HFC R134a, which is a highly flammable gas. It is essential to ensure that the tubes of the refrigerant circuit are not damaged.
ΟΟThe unit is not intended for use by children.
ΟΟKeep the areas surrounding the unit dry to avoid the risk of people slipping.
ΟΟThe unit must not be cleaned with a water jet.
Water
ΟΟAlways connect the water cooler to a water main that supplies drinking water only.
ΟΟUse of 3/8" diameter connections is recommended.
ΟΟTurn off the main water inlet tap if the unit is not to be used for a long period.
Electrical
ΟΟCheck that the voltage shown on the serial number plate corresponds to the voltage being supplied at the installation site.
ΟΟDo not use extension cables or multiple-power sockets. The machine must be located close enough to a standard power socket that the supplied power cable reaches without stretching.
ΟΟAfter installation, check that the machine is not standing on its power supply cable.
ΟΟEnsure that it is possible to disconnect the power supply either by removing the plug or via a two-pole circuit breaker placed upstream of the plug.
ΟΟBefore any maintenance or cleaning operation is carried out, remove the plug from the socket or disconnect the power supply.
ΟΟIf the power cable is damaged, it must be replaced by the manufacturer, by its technical support service or by a qualified technician.
ΟΟDo not position other electrical equipment in the immediate vicinity of the water cooler.
8