Elkay DSC2K Owner’s Manual

0 (0)
Elkay DSC2K Owner’s Manual

Installation and

Maintenance

Manual

COLUMN TAP

Table of Contents

Declaration of Conformity

2

Before You Begin –

 

Installing the Water Cooler and the

 

Association

2

Requirements for Installation

7

Supply head

11

Recommendations for Safeguarding the

 

Mounting Dimensions

7

Operating the Touch Control

 

Environment

3

Operating Environment

8

Keypad Fontemagna Bridge Only

16

Explanation of Warning/Safety Icons

3

Water

8

Programming the Touch Control

18

Introduction

4

Electrical

8

Keypad Fontemagna Bridge Only

Routine Maintenance

19

Components Guide

5

Tools You Will Need

9

Troubleshooting

22

Product Specifications

6

Unpacking the Kit

9

Replacement Parts

25

 

 

What’s in the Kit

10

 

 

 

 

NOTICE: Read the instructions in this manual and retain for future reference.

Carbonation Chiller, Fontemagna Bridge and Column Tap

Installation and Maintenance Manual

Declaration of Conformity

D.M. 174

Materials compliant for contact with drinking water

This unit is intended for the dispensing of drinking water, and so the materials that enter into direct contact with water meet the criteria for food-grade components pursuant to the current legislation. In addition, the unit is manufactured in compliance with Italian Ministerial Decrees 174 of 04/06/2004 and 25 of 02/07/2012.

Electrical safety

This water cooler is designed, manufactured and marketed in compliance with:

ΟΟthe safety objectives of the Low Voltage Directive 2006/95/EC;

ΟΟthe protection requirements of the Electromagnetic Compatibility Directive 2004/108/EC.

The electrical safety of the product is ensured only when it is properly connected to an efficient, legally compliant grounding circuit.

UL standard for safety of drinking water coolers, ANSI/UL 399, Issued: 2008/08/22, Ed: 7, Rev: 2013/10/18 and UL 60335-1

CSA standard for refrigeration equipment, CSA Column Tap2.2 No. 120, Issued: 2013/03/01, Ed: 4 and CAN/

CSA Column Tap2.2 No. 60335-1

Association

International Awards

2014 – BEST PROMOTION OF HEALTH AND HYDRATION

EUROPEAN AQUA AWARDS 2014, BUDAPEST

2013 – BEST PRODUCT INNOVATION

EUROPEAN AQUA AWARDS 2013, BERLIN

2012 – BEST ENVIRONMENTALLY FRIENDLY PRACTICE

EUROPEAN AQUA AWARDS 2012, ISTANBUL

2011 – BEST PRODUCT DESIGN/INNOVATION

EUROPEAN AQUA AWARDS 2011, ODESSA

2010 – BEST ENVIRONMENTALLY FRIENDLY PRACTICE

EUROPEAN AQUA AWARD 2010, PRAGUE

2

RecommendationsforSafeguardingtheEnvironment

Packaging materials

The packaging materials are 100% recyclable. Please follow the local guidelines on waste disposal.

For safety reasons keep the packaging material out of the reach and sight of children.

Scrappage

The Carbonation Chiller water cooler, Fontemagna Bridge and Column Tap supply head are made using recyclable material.

These units are marked in compliance with European Directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). By ensuring that the product is scrapped correctly, you will help to prevent potential negative consequences for the environment and for health. This symbol indicates that the product should not be treated as domestic waste but should be taken to a dedicated recycling center for electrical and electronic equipment. Immediately prior to scrapping, cut off the power cable.

For more information on the treatment, recovery and recycling of this product, please contact the appropriate local office, the waste disposal service or the reseller from which the product was purchased.

Explanation of Warning/Safety Icons

NOTICE: Indicates an instruction which, if not followed, could result in damage to product or property or poor product performance.

CAUTION: Indicates an instruction which, if not followed, could result in minor or moderate injury.

WARNING:Indicates an instruction which, if not followed, could result in serious injury or death.

1000002475 (Rev. C - 07/2015)

3

Carbonation Chiller, Fontemagna Bridge and Column Tap

Installation and Maintenance Manual

Introduction

The Carbonation Chiller water cooler, Fontemagna Bridge and Column Tap supply head bring contemporary style and state-of-the-art technology to commercial water dispensers. Carbonation Chiller undercounter water cooler can be used with either Fontemagna Bridge or Column Tap, combining professional performances with a modern, sleek design.

ΟΟMultiple dispensing options: cold still water, cold sparkling water, and room-temperature still water

ΟΟNatural materials throughout: stainless steel, aluminum, glass

ΟΟInternal components made entirely of stainless steel

Carbonation Chiller

ΟΟCooling serpentine coil made with the best stainless steel for drinkable water - AISI 316

ΟΟHigh-insulation ice bank ensures a high output of cold water, still and sparkling

Fontemagna Bridge

ΟΟElectronic keypad with glass cover, easy to use and hygienic, with touch control commands

ΟΟPreprogrammed quantities of water to minimize overflow and waste

ΟΟEnergy Saving command: when selected, this feature enables standby functionality of the unit, with consumption reduced by 75% compared to full functionality

ΟΟBactericidial UV lamp at exit of each tap

Column Tap

ΟΟSelf closing tap to avoid accidental water leakage

ΟΟCompensator included to regulate the flow of each spout

NOTICE: Due to rigorous testing, product may reasonably be expected to contain traces of sanitizing solution.

4

Components Guide

Carbonation Chiller

Fontemagna Bridge

Column Tap

Sparkling water

Room temperture

 

Compensator

water outlet

 

outlet

Cold water outlet

 

 

 

 

 

Sparkling water

 

 

 

nozzle

Power button

 

Touch Control

 

 

 

 

Thermostat

 

keypad

Cold water nozzle

 

 

 

 

 

Ice bank inlet

 

 

 

CO2 inlet

 

 

 

Ice bank overflow

 

Drip tray

 

Water inlet

 

 

 

Ice bank level

 

Sparkling water

Sparkling water

 

inlet

 

inlet

 

Room temperture

Cold water inlet

 

water inlet

 

Power cable

Cold water inlet

Power cable

 

 

Dispensing buttons –

 

small serving

 

large serving

Power

 

button

Fontemagna Bridge

Touch Control keypad

Energy

Saving

button

Cold

Cold still

sparkling

dispenser

dispenser

 

Room-temperature

still dispenser

1000002475 (Rev. C - 07/2015)

5

Carbonation Chiller, Fontemagna Bridge and Column Tap

Installation and Maintenance Manual

Product Specifications

 

Specification

Carbonation Chiller

Fontemagna Bridge

Column Tap

 

 

Cooling capacity gal/h (lt/h)

20 (80)

 

 

 

 

 

 

 

 

 

 

Continuous supply gal (lt)

12 (45)

 

 

 

 

 

 

 

 

 

 

Cold water temperature

37.4°F – 50°F

 

 

 

 

 

(3°C – 10°C)

 

 

 

 

Ice bank capacity gal (lt)

3.7 (14)

 

 

 

 

 

 

 

 

 

 

Ice bank lb (kg)

11 (5)

 

 

 

 

 

 

 

 

 

 

Cooling technology

ICE BANK single stainless

 

 

 

 

 

steel coil

 

 

 

 

Condensation

Forced ventilation (fan)

 

 

 

 

 

 

 

 

 

 

Adjustable thermostat

Yes

 

 

 

 

 

 

 

 

 

 

Refrigerant gas

R134a

 

 

 

 

 

 

 

 

 

 

Compressor

1/6 HP

 

 

 

 

 

 

 

 

 

 

Pump

Professional carbonator

 

 

 

 

 

pump

 

 

 

 

Inlet water pipe

ø 3/8"

ø 3/8"

ø 3/8”

 

 

 

 

 

 

 

 

Supply

115V - 60Hz

115V - 60Hz

 

 

 

 

(230V - 50Hz)

(230V - 50Hz)

 

 

 

Power

330W - 3.2A

50W - 0.44 A

 

 

 

 

 

 

 

 

 

Working room temperature

Min 41°F – Max 107.6°F

Min 41°F – Max 107.6°F

 

 

 

 

(Min 5°C – Max 42°C)

(Min 5°C – Max 42°C)

 

 

 

UNIT WEIGHT lb (kg)

59

33

9

 

 

 

(27)

(15)

(4)

 

 

SHIPPING WEIGHT lb (kg)

66

35

11

 

 

 

(30)

(16)

(5)

 

 

 

 

 

 

 

 

Dimensions W x D x H in (mm)

12.5 x 18.4 x 18.6

14.2 x 10.2 x 23.8

5.2 x 9.1 x 18.7

 

 

 

(317 x 467 x 472)

(361 x 290 x 605)

(132 x 231 x 475)

 

 

Dispensingareaheightin (mm)

 

12

12

 

 

 

 

(305)

(305)

 

 

Packaging dimensions in (mm)

16.5 x 23.2 x 28.3

16.1 x 30.5 x 12.0

6.7 x 6.7 x 28.3

 

 

 

(420 x 590 x 720)

(410 x 775 x 305)

(170 x 170 x 720)

 

 

Dispensing

3 supply option

3 supply option (sparkling,

2 supply option (sparkling

 

 

 

(sparkling, cold and

cold and room temperature

and cold water)

 

 

 

room temperature

water) with customizable

 

 

 

 

water)

portion control system

 

 

 

 

 

 

 

 

 

Mechanical outlet taps

 

 

HQ stainless steel

 

 

 

 

 

 

 

 

Push buttons

 

Electronic touch screen

 

 

 

 

 

board

 

 

 

Energy Saving device

 

Included, dedicated push

 

 

 

 

 

buttons

 

 

 

Materials

All robust stainless steel

All robust stainless steel,

Stainless steel (water supply

 

 

 

parts

aluminium and glass

path) and nickel brass

 

 

 

 

 

(body)

 

6

Before You Begin – Requirements for Installation

Mounting Dimensions (Carbonation Chiller only)

Under counter (includes 4" clearance on sides and back)

Depth 24.6" (625mm)

Footprint: 12.5" x 18.4" 317mm x 467mm

Depth 3.88" (99mm)

Height:

12.75"

(324mm)

Width 3.25" (83mm)

Height: 28" (711mm)

Water filter

Width 20.5"(520mm)

Height 26.6" (675mm)

Diameter 8" (203mm)

CO2 cylinder (typical, 20 pound)

1000002475 (Rev. C - 07/2015)

7

Carbonation Chiller, Fontemagna Bridge and Column Tap

Installation and Maintenance Manual

Operating Environment

ΟΟInstall the machine in a clean, dry, well-ventilated room. It is designed to function correctly in environments with a temperature of 16°C to 32°C – Climatic Class N, (between 61°F and 90°F).

ΟΟCheck that the water cooler is level, that it is on a surface that can support its weight and in an environment suitable for its size and use.

ΟΟDo not place the machine near a source of heat.

ΟΟTo guarantee adequate ventilation, leave at least 6" (152 mm) of space around the unit.

ΟΟTake care not to damage the cooling fluid circuit: Carbonation Chiller is filled with HFC R134a, which is a highly flammable gas. It is essential to ensure that the tubes of the refrigerant circuit are not damaged.

ΟΟThe unit is not intended for use by children.

ΟΟKeep the areas surrounding the unit dry to avoid the risk of people slipping.

ΟΟThe unit must not be cleaned with a water jet.

Water

ΟΟAlways connect the water cooler to a water main that supplies drinking water only.

ΟΟUse of 3/8" diameter connections is recommended.

ΟΟTurn off the main water inlet tap if the unit is not to be used for a long period.

Electrical

ΟΟCheck that the voltage shown on the serial number plate corresponds to the voltage being supplied at the installation site.

ΟΟDo not use extension cables or multiple-power sockets. The machine must be located close enough to a standard power socket that the supplied power cable reaches without stretching.

ΟΟAfter installation, check that the machine is not standing on its power supply cable.

ΟΟEnsure that it is possible to disconnect the power supply either by removing the plug or via a two-pole circuit breaker placed upstream of the plug.

ΟΟBefore any maintenance or cleaning operation is carried out, remove the plug from the socket or disconnect the power supply.

ΟΟIf the power cable is damaged, it must be replaced by the manufacturer, by its technical support service or by a qualified technician.

ΟΟDo not position other electrical equipment in the immediate vicinity of the water cooler.

8

Loading...
+ 16 hidden pages