PROFESSIONAL LAUNDRY
Heavy duty flatwork ironer
C-Flex 900, 1200
Features and benefits
•Chest type industrial ironer with mobile chest and fixed roll, offering a constant pressure and a maximum ironing surface for the utmost ironing quality
•Steam or thermal fluid heating
•The unique design of the chest and roll combined with an improved thermal insulation give a thermal output close to 97%
•Up to three chest can be mounted together for a 50m/min maximum ironing speed
•Simple and reliable drive, possible thanks to the fixed roll technology
•One adjustable suction fan per roll for an improved vapor suction
• Springpress® fitting for an optimum roll and chest contact and an optimized vapor extraction
Main options
•Stainless steel Springpress® fitting for an extended longevity
•Nomex padding withstand temperatures above 180°C
•Extra insulation of the casings for a lower energy consumption and an improved working environment
•Vacuum feeding table for an easier use
•Preset ironing speeds or special speed ranges to customize the ironing to the user specificities
•Connection with feeding and folding systems
Main specifications |
|
C-Flex 900 |
C-Flex 1200 |
|
Max. water evaporation* |
l/h |
205-795 |
210-1260 |
|
Cylinder |
number |
|
1-3 |
1-3 |
|
diameter |
mm |
900 |
1200 |
|
length |
mm |
2700, 3000, 3300, 3500 |
3000, 3300, 3500, 4200 |
Ironing speed** |
|
m/min |
4-51 |
6-51 |
Heating |
steam consumption*** |
kg/h |
240-960 |
295-1530 |
|
|
|
|
|
*12 bars steam heating, smallest – biggest machine and 100% cylinder use, see detailed data
**See detailed data for available speed ranges per dimension
***12 bar steam heating, smallest – biggest machine, see detailed data
Electrical connections |
|
927 |
930 |
933 |
935 |
||
|
|||||||
Voltage |
|
|
|
|
|
||
|
|
400-415V 3AC 50Hz – 1 roll |
kW |
|
|
4.6 |
|
|
|
400-415V 3AC 50Hz – 2 rolls |
kW |
|
|
12 |
|
|
|
400-415V 3AC 50Hz – 3 rolls |
kW |
|
|
22 |
|
|
|
|
|
|
|
|
|
Steam and air connections |
|
|
|
|
|
||
Max. steam pressure |
kPa |
|
1400 |
|
|||
Compressed air |
DN |
|
|
15 |
|
||
|
|
|
|
|
|
||
1 roll |
|
|
|
|
|
||
Steam |
DN |
|
|
32 |
|
||
Condensate |
DN |
|
|
25 |
|
||
Exhaust dia. (K) |
mm |
|
|
200 |
|
||
Evacuated air |
m3/h |
|
2000 |
|
|||
2 rolls |
|
|
|
|
|
||
Steam |
DN |
|
|
40 |
|
||
Condensate |
DN |
|
|
32 |
|
||
Exhaust dia. (K) |
mm |
|
2 x 200 |
|
|||
Evacuated air |
m3/h |
|
2 x 2000 |
|
|||
3 rolls |
|
|
|
|
|
||
Steam |
DN |
|
|
50 |
|
||
Condensate |
DN |
|
|
40 |
|
||
Exhaust dia. (K) |
mm |
|
3 x 200 |
|
|||
Evacuated air |
m3/h |
|
3 x 2000 |
|
|||
Sound level |
|
|
|
|
|
||
Airborne sound level |
dB(A) |
|
|
66 |
|
||
|
|
|
|
|
|
|
|
Heat emission |
|
|
|
|
|
||
% of installed power, standard insulation |
|
|
|
5 |
|
||
% of installed power, extra insulation |
|
|
|
3 |
|
||
|
|
|
|
|
|
|
|
Performances and energy consumption |
|
|
|
|
|
||
1 roll |
|
|
|
|
|
||
Max. water evaporation (14 bar) |
l/h |
205 |
225 |
250 |
265 |
||
Steam average consumption (12 bar) |
kg/h |
240 |
270 |
300 |
320 |
||
Average linen output (12 bar)* |
kg/h |
330 |
370 |
410 |
435 |
||
Ironing speed** |
m/min |
|
|
5-15 |
|
||
|
|
|
|
|
|
||
2 rolls |
|
|
|
|
|
||
Max. water evaporation (14 bar) |
l/h |
410 |
450 |
500 |
530 |
||
Steam average consumption (12 bar) |
kg/h |
480 |
540 |
600 |
640 |
||
Average linen output (12 bar)* |
kg/h |
660 |
740 |
820 |
870 |
||
Ironing speed** |
m/min |
|
9-27 |
|
|||
|
|
|
|
|
|
||
3 rolls |
|
|
|
|
|
||
Max. water evaporation (14 bar) |
l/h |
615 |
675 |
750 |
795 |
||
Steam average consumption (12 bar) |
kg/h |
720 |
810 |
900 |
960 |
||
Average linen output (12 bar)* |
kg/h |
940 |
1110 |
1230 |
1305 |
||
Ironing speed** |
m/min |
|
14-42 |
|
|||
|
|
|
|
|
|
|
|
Dimensions |
|
|
|
|
|
||
A |
width |
mm |
3900 |
4200 |
4500 |
4700 |
|
B |
ironing width |
mm |
2700 |
3000 |
3300 |
3500 |
|
|
|
|
|
|
|
||
C |
length 1 roll |
mm |
|
1685 |
|
||
C |
length 2 rolls |
mm |
|
2955 |
|
||
C |
length 3 rolls |
mm |
|
4225 |
|
||
D |
height |
mm |
|
1560 |
|
||
|
|
|
|
|
|
|
|
Net weight |
|
|
|
|
|
||
1 roll |
kg |
3010 |
3200 |
3400 |
3530 |
||
2 rolls |
kg |
5980 |
6360 |
6760 |
7030 |
||
3 rolls |
kg |
8950 |
9550 |
10170 |
10600 |
||
|
|
|
|
|
|
|
|
*50% residual moisture, 140 gr/m2 polyester-cotton linen, 100% cylinder use