DeWalt DWFP12569 User Manual

0 (0)

DWFP12569_9R202311RA_DWLT_2in1 FLOORING TOOL MANUAL _MAN_JM:103697RevE_MIIIFS_MIIIFN.qxd 2012/9/25

DWFP12569

2-N-1™ FLOORING TOOL

HERRAMIENTA 2 EN 1™ PARA

INSTALACIÓN DE PISOS

OUTIL À PLANCHER 2 EN ™

INSTRUCTION MANUAL

GUIDE D’UTILISATION

MANUAL DE INSTRUCCIONES

INSTRUCTIVO DE OPERACIÓN, CENTROS DE

SERVICIO Y PÓLIZA DE GARANTÍA.

ADVERTENCIA: LÉASE ESTE INSTRUCTIVO

ANTES DE USAR EL PRODUCTO.

INSTRUCTIONS DE FONCTIONNEMENT,

CENTRES DE SERVICE, POLITIQUE DE

GARANTIE. AVERTISSEMENT : LISEZ CES

INSTRUCTIONS AVANT D'UTILISER L'APPAREIL.

BEFORE OPERATING THIS TOOL, ALL OPERATORS SHOULD STUDY THIS MANUAL TO UNDERSTAND AND FOLLOW THE SAFETY WARNINGS AND INSTRUCTIONS. KEEP THESE INSTRUCTIONS WITH THE TOOL FOR FUTURE REFERENCE. IF YOU HAVE ANY QUESTIONS, CONTACT YOUR DEWALT REPRESENTATIVE OR DISTRIBUTOR.

ANTES DE OPERAR ESTA HERRAMIENTA, TODOS LOS OPERADORES DEBERÁN ESTUDIAR ESTE MANUAL PARA PODER COMPRENDER Y SEGUIR LAS ADVERTENCIAS SOBRE SEGURIDAD Y LAS INSTRUCCIONES. MANTENGA ESTAS INSTRUCCIONES CON LA HERRAMIENTA PARA FUTURA REFERENCIA, SI TIENE ALGUNA DUDA, COMUNÍQUESE CON SU REPRESENTANTE DE DEWALT O CON SU DISTRIBUIDOR.

LIRE ATTENTIVEMENT LE PRÉSENT MANUEL AVANT D’UTILISER L’APPAREIL. PRÉTER UNE ATTENTION TOUTE PARTICULIÈRE AUX CONSIGNES DE SÉCURITÉ ET AUX AVERTISSEMENTS. GARDER CE MANUEL AVEC L’OUTIL POUR FUTUR RÉFÉRENCE. SI VOUS AVEZ DES QUESTIONS, CONTACTEZ VOTRE REPRÉSENTANT OU VOTRE CONCESSIONNAIRE DEWALT.

If you have questions or comments, contact us.

Pour toute question ou tout commentaire, nous contacter.

Si tiene dudas o comentarios, contáctenos.

1-800-4-DeWALT • www.dewalt.com

9R202311RA 8/12

DWFP12569_9R202311RA_DWLT_2in1 FLOORING TOOL MANUAL _MAN_JM:103697RevE_MIIIFS_MIIIFN.qxd 2012/9/25

INTRODUCTION

DEWALT tools are precision-built tools, designed for precise, high volume nailing.These tools will deliver efficient, dependable service when used correctly and with care. As with any fine power tool, for best performance the manufacturer’s instructions must be followed. Please study this manual before operating the tool and understand the safety warnings and cautions. The instructions on installation, operation and maintenance should be read carefully, and the manual kept for reference. NOTE: Additional safety measures may be required because of your particular application of the tool. Contact your DEWALT representative or distributor with any questions concerning the tool and its use. DeWALT Industrial Tool Co., 701 East Joppa Road, Baltimore, MD 21286, call 1-800-4-DeWalt (1-800-433-9258) or visit our website www.dewalt.com.

INDEX

 

Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 3

Tool Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 4

Air Supply: Fittings, Hoses, Filters, Air Consumption, Regulators,

 

Operating Pressure, Setting Correct Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 5

Lubrication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 5

Loading the Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 6

Maintaining the Pneumatic Tool . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 7

Maintaining the DWFP12569 Series Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 8

Trouble Shooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. 9

Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

10

NOTE:

DEWALT tools have been engineered to provide excellent customer satisfaction and are designed to achieve maximum performance when used with fasteners engineered to the same exacting standards. DEWALT cannot assume responsibility for product performance if our tools are used with fasteners or accessories not meeting the specific requirements established for fasteners, staples and accessories.

THREE YEARS LIMITED WARRANTY

DEWALT will repair, without charge, any defects due to faulty materials or workmanship for three years from the date of purchase. This warranty does not cover part failure due to normal wear or tool abuse. For further detail of warranty coverage and warranty repair information, visit www.dewalt.com or call 1-800-4-DEWALT (1-800-433- 9258). This warranty does not apply to accessories or damage caused where repairs have been made or attempted by others. This warranty gives you specific legal rights and you may have other rights which vary in certain states or provinces.

In addition to the warranty, DEWALT tools are covered by our:

1 YEAR FREE SERVICE: DEWALT will maintain the tool and replace worn parts caused by normal use, for free, any time during the first year after purchase. Nailer wear items, such as o-rings and driver blades, are not covered.

90 DAY MONEY BACK GUARANTEE : If you are not completely satisfied with the performance of your DEWALT Power Tool, Laser, or Nailer for any reason, you can return it within 90 days from the date of purchase with a receipt for a full refund – no questions asked.

LATIN AMERICA: This warranty does not apply to products sold in Latin America. For products sold in Latin America, see country specific warranty information contained in the packaging, call the local company or see website for warranty information.

WARNING L ABEL REPLACEMENT

If your warning labels become illegible or are missing, call 1-800-4-DEWALT for a freereplacement.

-2-

DWFP12569_9R202311RA_DWLT_2in1 FLOORING TOOL MANUAL _MAN_JM:103697RevE_MIIIFS_MIIIFN.qxd 2012/9/25

SAFETY INSTRUCTIONS

EYE PROTECTION which conforms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when connecting to air supply, loading, operating or servicing this tool. Eye protection is required to guard against flying fasteners and debris, which could cause severe eye injury.

The employer and/or user must ensure that proper eye protection is worn. Eye protection equipment must conform to the requirements of the American National Standards Institute, ANSI CAN/CSA Z94.3 and provide both frontal and side protection. NOTE: Non-side shielded spectacles and face shields alone do not provide adequate protection.

CAUTION: Additional Safety Protection will be required in some environments. For example, the working area may include exposure to noise level which can lead to hearing damage. The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area. Some environments will require the use of head protection equipment. When required, the employer and user must ensure that head protection conforming to ANSI CAN/CSA Z89.1 is used.

AIR SUPPLY AND CONNECTIONS

Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as tool may explode, possibly causing injury.

Do not use supply sources which can potentially exceed 200 P.S.I.G. (14kg/cm2 ) as tool may burst, possibly causing injury.

The connector on the tool must not hold pressure when air supply is disconnected. If a wrong fitting is used, the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury.

Do not pull trigger or depress contact arm while connected to the air supply as the tool may cycle, possibly causing injury.

Always disconnect air supply: 1.) Before making adjustments; 2.) When servicing the tool; 3.) When clearing a jam; 4.) When tool is not in use; 5.) When moving to a different work area, as accidental actuation may occur, possibly causing injury.

LOADING TOOL

When loading tool: 1.) Never place a hand or any part of body in fastener discharge area of tool; 2.) Never point tool at anyone; 3.) Do not pull the trigger or depress the trip as accidental actuation may occur, possibly causing injury.

OPERATION

Always handle the tool with care: 1.) Never engage in horseplay; 2.) Never pull the trigger unless nose is directed toward the work; 3.) Keep others a safe distance from the tool while tool is in operation as accidental actuation may occur, possibly causing injury.

The operator must not hold the trigger pulled on contact arm tools except during fastening operation as serious injury could result if the trip accidentally contacted someone or something, causing the tool to cycle.

Keep hands and body away from the discharge area of the tool. A contact arm tool may bounce from the recoil of driving a fastener and an unwanted second fastener may be driven possibly causing injury.

Check operation of the contact arm mechanism frequently. Do not use the tool if the arm is not working correctly as accidental driving of a fastener may result. Do not interfere with the proper operation of the contact arm mechanism.

Do not drive fasteners on top of other fasteners or with the tool at an overly steep angle as this may cause deflection of fasteners which could cause injury.

Do not drive fasteners close to the edge of the work piece as the wood may split, allowing the fastener to be deflected possibly causing injury.

This nailer produces SPARKS during operation. NEVER use the nailer near flammable substances, gases or vapors including lacquer, paint, benzine, thinner, gasoline, adhesives, mastics, glues or any other material that is -- or the vapors, fumes or byproducts of which are -- flammable, combustible or explosive. Using the nailer in any such environment could cause an EXPLOSION resulting in personal injury or death to user and bystanders.

MAINTAINING THE TOOL

When working on air tools note the warnings in this manual and use extra care when evaluating problem tools.

-3-

DWFP12569_9R202311RA_DWLT_2in1 FLOORING TOOL MANUAL _MAN_JM:103697RevE_MIIIFS_MIIIFN.qxd 2012/9/25

DWFP12569 TOOL SPECIFICATIONS

All dimentions in inches unless otherwise specified

MODEL

LENGTH

HEIGHT

WIDTH

WEIGHT

 

 

 

 

 

DWFP12569

20.35” (517 mm)

22.08” (561 mm)

3.15” (80 mm)

10.85 lbs (4.9 kg)

 

 

 

 

 

FASTENER SPECIFICATIONS:

MODEL

FASTENER

CROWN WIDTH

GAUGE

FASTENER RANGE

 

 

 

 

 

DWFP12569

BCS15xx

1/2” (13mm)

15-1/2 Ga., 1/2"

1-1/2" (38mm) to

 

 

 

Crown Staples

2" (50mm)

DWFP12569

FLN-xxx

-

16 Ga. "L" shape

1-1/2" (38mm) to

 

 

 

Cleat Nails

2" (50mm)

TOOL AIR FITTING:

This tool uses a 1/4” N.P.T. male plug. The inside diameter should be .200” (5mm) or larger. The fitting must be capable of discharging tool air pressure when disconnected from the air supply.

OPERATING PRESSURE:

70 to 100 p.s.i.g. (4.9 to 7.0 kg/cm²). Select the operating pressure within this range for best fastener performance. DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE.

AIR CONSUMPTION:

The DWFP12569 requires 3.7 cubic feet per minute (105 liters per minute) of free air to operate at the rate of 60 fasteners per minute, at 80 p.s.i. (5.6 kg/cm2). Take the actual rate at which the tool will be run to determine the amount of air required. For instance, if your fastener usage averages 30 fasteners per minute, you need 50% of the tool’s c.f.m. of free air which is required to operate the tool at 60 fasteners per minute.

OPERATION

Caution Regarding Use of this Tool to Install Pre-finished Flooring

This DWFP12569 Flooring Tool was designed for use in installing unfinished hardwood flooring. It can be used to install pre-finished flooring however caution must be used to ensure that the finish is not damaged by the tool. It is recommended that the tool be tested on a sample section to be certain that the tool and technique of use do not leave marks on the finish. This procedure should be followed before each job due to variations in flooring and tool condition.

-4-

DWFP12569_9R202311RA_DWLT_2in1 FLOORING TOOL MANUAL _MAN_JM:103697RevE_MIIIFS_MIIIFN.qxd 2012/9/25

AIR SUPPLY AND CONNECTIONS

Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as tool may explode, possibly causing injury.

FITTINGS:

Install a male plug on the tool which is free flowing and which will release air pressure from the tool when disconnected from the supply source.

HOSES:

Air hoses should have a minimum of 150 p.s.i. (10.6 kg/cm2) working pressure rating or 150 percent of the maximum pressure that could be produced in the air system. The supply hose should contain a fitting that will provide “quick disconnecting” from the male plug on the tool.

SUPPLY SOURCE:

Use only clean regulated compressed air as a power source for this tool. NEVER USE OXYGEN, COMBUSTIBLE

GASES, OR BOTTLED GASES, AS A POWER SOURCE FOR THIS TOOL AS TOOL MAY EXPLODE.

REGULATOR:

A pressure regulator with an operating pressure of 0 - 125 p.s.i. (0 - 8.79 KG/CM2) is required to control the operat ingi pressure for safe operation of this tool. Do not connect this tool to air pressure which can potentially exceed 200 p.s.i. (14 KG/CM2) as tool may fracture or burst, possibly causing injury.

OPERATING PRESSURE:

Do not exceed recommended maximum operating pressure as tool wear will be greatly increased.The air supply must be capable of maintaining the operating pressure at the tool. Pressure drops in the air supply can reduce the tool’s driving power. Refer to “TOOL SPECIFICATIONS” for setting the correct operating pressure for the tool.

FILTER:

Dirt and water in the air supply are major causes of wear in pneumatic tools. A filter will help to get the best performance and minimum wear from the tool. The filter must have adequate flow capacity for the specific installation. The filter has to be kept clean to be effective in providing clean compressed air to the tool. Consult the manufacturer’s instructions on proper maintenance of your filter. A dirty and clogged filter will cause a pressure drop which will reduce the tool’s performance.

LUBRICATION

Frequent, but not excessive, lubrication is required for best performance. Use Air Tool Lubricant, Mobil Velocite #10, or equivalent. Do not use detergent oil or additives as these lubricants will cause accelerated wear to the seals and bumpers in the tool, resulting in poor tool performance and frequent tool maintenance. Only a few drops of oil at a time is necessary. Too much oil will only collect inside the tool and will be noticeable in the exhaust cycle.

COLD WEATHER OPERATION:

For cold weather operation, near and below freezing, the moisture in the air line may freeze and prevent tool operation. We recommend the use of winter formula air tool lubricant or permanent antifreeze (ethylene glycol) as a cold weather lubricant.

CAUTION: Do not store tools in a cold weather environment to prevent frost or ice formation on the tools operating valves and mechanisms that could cause tool failure.

NOTE:Some commercial air line drying liquids are harmful to “O”-rings and seals – do not use these low temperature air dryers without checking compatibility.

-5-

DeWalt DWFP12569 User Manual

DWFP12569_9R202311RA_DWLT_2in1 FLOORING TOOL MANUAL _MAN_JM:103697RevE_MIIIFS_MIIIFN.qxd 2012/9/25

LOADING THE DWFP12569

EYE PROTECTION which conforms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when connecting to air supply, loading, operating or servicing this tool. Eye protection is required to guard against flying fasteners and debris, which could cause severe eye injury.

The employer and/or user must ensure that proper eye protection is worn. Eye protection equipment must conform to the requirements of the American National Standards Institute, ANSI CAN/CSA Z89.1 and provide both frontal and side protection. NOTE: Non-side shielded spectacles and face shields alone do not provide adequate protection.

TO PREVENT ACCIDENTAL INJURIES:

Never place a hand or any other part of the body in nail discharge area of tool while the air supply is connected.

Never point the tool at anyone else.

Never engage in horseplay.

Never actuate the tool unless nose is directed at the work.

Always handle the tool with care.

Do not actuate the tool while loading.

DWFP12569

CLEAT LOADING:

Retract pusher until it is in the locked position. Insert a stick of cleats or staples. Push the detent to unlock the pusher. Slide pusher to the fully forward position. The tool is now ready to operate.

NOTE: Use only nails recommended for use in the DWFP12569 nailers or nails which meet the

DEWALT specifications.

BEFORE HANDLING OR OPERATING THIS TOOL:

I.READ AND UNDERSTAND THE WARNINGS CONTAINED IN THIS MANUAL.

II.REFER TO “TOOL SPECIFICATIONS” IN THIS MANUAL TO IDENTIFY THE OPERATING SYSTEM ON YOUR TOOL.

-6-

DWFP12569_9R202311RA_DWLT_2in1 FLOORING TOOL MANUAL _MAN_JM:103697RevE_MIIIFS_MIIIFN.qxd 2012/9/25

IN ADDITION TO THE OTHER WARNINGS CONTAINED IN THIS MANUAL

OBSERVE THE FOLLOWING FOR SAFE OPERATION

Use the DEWALT pneumatic tool only for the purpose for which it was designed.

Never use this tool in a manner that could cause a fastener to be directed toward the user or others in the work area.

Do not use the tool as a hammer.

Always carry the tool by the handle. Never carry the tool by the air hose.

Do not alter or modify this tool from the original design or function without approval from DEWALT.

Always be aware that misuse and improper handling of this tool can cause injury to yourself and others.

Before using the tool, verify that the actuator is in the non-actuated position. With the tool disconnected from the air supply, depress the actuator and confirm it returns to the non-actuated position.

Never leave a tool unattended with the air hose attached.

Do not operate this tool if it does not contain a legible WARNING LABEL.

Do not continue to use a tool that leaks air or does not function properly. Notify your nearest DEWALT representative if your tool continues to experience functional problems.

MAINTAINING THE PNEUMATIC TOOL

When working on air tools, note the warnings in this manual and use extra care evaluating problem tools.

CAUTION: Pusher spring (constant force spring). Caution must be used when working with the spring assembly. The spring is wrapped around, but not attached to, a roller. If the spring is extended beyond its length, the end will come off the roller and the spring will roll up with a snap, with a chance of pinching your hand. Also the edges of the spring are very thin and could cut. Care must also be taken to insure no permanent kinks are put in the spring as this will reduce the springs force.

REPLACEMENT PARTS:

DEWALT replacement parts are recommended. Do not use modified parts or parts which will not give equivalent performance to the original equipment.

ASSEMBLY PROCEDURE FOR SEALS:

When repairing a tool, make sure the internal parts are clean and lubricated. Use Parker “O”-LUBE or equivalent on all “O”-rings. Coat each “O”-ring with “O”-LUBE before assembling. Use a small amount of oil on all moving surfaces and pivots. After reassembly add a few drops of DEWALT Air Tool Lubricant through the air line fitting before testing.

AIR SUPPLY-PRESSURE AND VOLUME:

Air volume is as important as air pressure. The air volume supplied to the tool may be inadequate because of undersize fittings and hoses, or from the effects of dirt and water in the system. Restricted air flow will prevent the tool from receiving an adequate volume of air, even though the pressure reading is high. The results will be slow operation, misfeeds or reduced driving power. Before evaluating tool problems for these symptoms, trace the air supply from the tool to the supply source for restrictive connectors, swivel fittings, low points containing water and anything else that would prevent full volume flow of air to the tool.

-7-

DWFP12569_9R202311RA_DWLT_2in1 FLOORING TOOL MANUAL _MAN_JM:103697RevE_MIIIFS_MIIIFN.qxd 2012/9/25

MAINTAINING THE DWFP12569 SERIES TOOLS

TO REPLACE PISTON:

a.Insert the flats on the lower end of the driver piston stem carefully into the end of piston and plunger wrench, BC1009.

b.Using another special wrench, BC1009, or another wrench of the proper size, unscrew the plunger from the upper end of the stem. After this is done, it will be possible to lift the poppet off the stem.

c.Place the special wrench, BC1009, down over the piston stem onto the driver piston, locking the piston ears in the slots in the wrench. Unscrew the piston from the stem.

TO REPLACE DRIVER:

a.It is not necessary to disassemble the piston-poppet-driver assembly to replace the driver. Pull the poppet up on the driver piston stem as far as it will go.

b.Insert special wrench, BC1009, over the driver piston, locking the piston ears in the slots in the wrench. Unscrew the piston from threaded portion of the stem.

c.To remove the driver blade from the piston stem, push the driver blade pin out of the stem. This will release

the blade.

d.Insert new driver blade into the slot in the end of the driver piston stem and assemble the driver blade pin. Test the side play in the driver blade by grasping the driver piston stem in one hand and the blade in the other and moving the blade sideways in alignment with the slot in the stem. There should be a small amount of side play in the blade. This is necessary to take care of any slight misalignment between the blade and guide in the nose. If there is no side play, the blade should be removed and the top (pin end) just barely dressed off with a stone. It is not necessary to do more than smooth off the top to get the necessary side play. Do not grind. Reinsert the blade and pin in the stem and test for side play once more. Repeat as necessary to get this small amount of side play. Carefully examine the large threaded portion of the piston stem. A nylon lock can be seen imbedded in a recessed hole in the stem. It is very important that this nylon lock can be replaced when its locking efficiency has been reduced through several disassemblies of the piston. It is necessary to use the sharp point of a knife, or some such instrument, to remove this nylon lock. Insert a new one by setting it into the recessed hole in the stem, and tapping it gently until firmly seated. Reverse these instructions to reassemble.

e.Assemble plunger flush with end of piston stem.