Apple Color Onescanner 600.27 Service Manual

K
Service Source

Color OneScanner 600/27

K
Service Source

Basics

Apple Color OneScanner 600/27

Overview

Color OneScanner 600/27
The Color OneScanner 600/ 27 is a compact, digital­image color scanner with a maximum mechanical resolution of 300 x 600 dpi.
An optional accessory for the Color OneScanner 600/27 is an Automatic Document
Automatic Document Feeder
Feeder (ADF) with a 20­sheet capacity paper tray.

Scanner Features

Features of the Color OneScanner 600/27 include the following:
• 300 x 600 dpi optical, 2400 x 2400 dpi interpolated, resolution for improved Optical Character Recognition (OCR) accuracy
• 27-bit scanning depth color that recognizes up to 134­million colors
• Support for PICT, TIFF, JPEG, EPS, BMP, and Photoshop; compatible with most popular word processing, presentation, image-editing, page layout, and web-authoring software for the Macintosh
• OneScanner Dispatcher software that integrates with popular applications and provides the tools to scan, edit, and archive images or documents; supports Drag and Drop
• Small desktop footprint of 16.3 in by 11.3 in
• ColorSync for the closest possible color match between what is scanned, seen on the monitor, or printed
• Xerox TextBridge for converting scanned documents into editable text or HTML format for a Web page
• Optional 20-sheet capacity Automatic Document Feeder

Scanner Operation

Clicking the icon at left launches a MoviePlayer animation sequence that shows the following scanning cycles:
• Flatbed scanning where the document remains stationary and the scanner lamp moves to scan from the front
• Automatic Document Feeder (ADF) scanning where the document moves and the scanner lamp remains in one position to scan from the front
Note:
Also shown in the animation sequence is Transparent Media Adapter (TMA) scanning where the document remains stationary and the TMA lamp moves to scan from the back. This type of scanning is available with the TMA option for the Apple Color OneScanner 1200/30. A TMA option is not available for the Apple Color OneScanner 600/27.

Optical Assembly Handling Precautions

Issue
: The Color One Scanner 600/27 optical assembly is being damaged during removal.
Solution:
by the longer sides (see illustration on next page) so that the printed circuit board (CCD unit) on the underside will not be damaged. The CCD unit is a delicate part located on the front, or shorter side of the assembly. If a service provider grabs or touches the CCD unit while removing or replacing the scanner, the scanner may not function. In addition, new packing was designed for the scanner unit.
Note
Assembly in Take Apart.
Apple recommends handling the scanner assembly
: For additional information, refer to the Optical
Hold or lift the optical assembly by the long sides,
CCD Unit
Mirrors
never by the shorter sides.
Caution:
Do not touch the printed circuit board (CCD Unit) or the mirrors.
K
Service Source
Specifications
Color OneScanner 600/27
Specifications Characteristics - 1

Characteristics

Scanner T ype

Scanner Resolution

Maximum Document Size

Speed

Interface

Flatbed, Single pass, 27-bit scanning
300 x 600 dpi 2400 x 2400 dpi interpolated
8.5 by 11.5 in.
8.5 by 14 in. with optional Automatic Document Feeder
Color: 20 seconds (US letter size) Monochrome: 10 seconds (US letter size)
SCSI-2
Specifications Electrical - 2

Electrical

Line V oltage

Frequency

Power Consumption

100/120/200/220/240 VAC ± 10%
48–62 Hz ± 10
35 W (maximum)
Specifications Physical - 3

Physical

Size

Weight

Height: 3.1 in. (79 mm) Width: 11.3 in. (287 mm) Depth: 16.3 in. (414 mm)
13.2 lb. (6 kg)

Environmental

Temperature

Relative Humidity

50–90.5°F (10–32.5°C)
20–80% noncondensing
K
Service Source

Troubleshooting

Color OneScanner 600/27
Troubleshooting General/ - 1

General

The Symptom Charts included in this chapter will help you diagnose specific symptoms related to your product. Because cures are listed on the charts in the order of most likely solution, try the first cure first. Verify whether or not the product continues to exhibit the symptom. If the symptom persists, try the next cure. (Note: If you have replaced a module, reinstall the original module before you proceed to the next cure.)
For additional assistance, contact Apple Technical Support.
Troubleshooting Wiring Diagram/ - 2

Wiring Diagram

CDD Drive Board
(Optical Assembly)
J201
1 2 3 4 5 6 7 8 9 10 11 12 13
YEL
YEL
YEL
YEL
YEL
YEL
YEL
YEL
YEL
YEL
YEL
YEL
Drive Motor
LED
1 2 3
J401
Inverter
Scanning Lamp (Optical Assembly)
Board
J402
1 2 3
BRN ORN RED YEL
RED BLK
RED BLU WHT
BRN BLK ORN BLK BLK BLU
J301
J311
A
1 2
A*
3
B
4
B*
J309
12+5V
GND
J310
1
+24V
2
GND
3
LON*
J307
1
+5V
2
DGND
3
+12V
4
AGND
5
24V GND
6
+24V
1 2 3 4 5 6 7 8 9 10 11 12 13
BGR
GND
+12V
+A5V
CPCKN
RSN
SPCKN
SHN
F2N
F1N
J306
1
HPSNS
2
GND
3
VCC
Logic Board
BRN YEL BLU
Home
Position
Sensor
1 2 3
WHT WHT
1 2 3 4 5 6
J101
Power Supply Board
Troubleshooting Symptom Charts/Normal Startup Sequence (Flatbed Scanning) -

Symptom Charts

Normal Startup Sequence (Flatbed Scanning)

Important:
the startup sequence. Even when turned off, some computers will not allow the scanner’s normal startup sequence to begin if the SCSI cable is connected.
1 Power on 2 Power LED lights 3 Logic board self-tests 4 Lamp turns on 5 Optical assembly moves to home position sensor at top of
6 Lamp turns off, then on 7 Lamp intensity checked with reflection of white on back of
8 Origin of scan is determined by black strip on back of
9 Lamp moves about 3 mm down 10 Lamp moves back to home position sensor 11 Lamp turns off 12 Ready
Disconnect the scanner’s SCSI cable before beginning
glass
glass
glass

Startup Troubleshooting Tips

When scanner is turned on, there is a chattering sound and it will not scan.
When trying to scan from the Dispatch software, this message appears: “Unable to initialize the scanner driver. Either the scanner is not turned on, connected, or already in use by another application.”
The SCSI select switch doesn’t select the correct SCSI ID.
Unlock the scanner by opening the top cover and using a coin or slotted screwdriver to turn the locking mechanism, located at the top of the glass. unlock icon is at 90 degrees from the slot. See the Additional Procedures chapter for more information.
1 The most common cause is that the scanner was turned on
after the Macintosh. Always make sure the scanner is turned on, then turn on the Macintosh. Observe the INITs as the Macintosh starts up. The INIT for the scanner appears as a side view of the scanner. This is the driver loading.
2 If the scanner INIT does not appear, reinstall the scanner
driver. If the icon appears with an “X” through it, there is a SCSI problem.
3 Check the SCSI ID and cables.
The label may not be lined up correctly to the position of the switch. Put the switch in the 12 o’clock position and then count to the correct SCSI ID.
Note:
The arrow that points to the lock or
Troubleshooting Symptom Charts/General Troubleshooting - 4

General Troubleshooting

No LED (no power) 1 Check external power cable and incoming voltage.
2 Remove the covers, glass, and optical assembly. Check AC
voltage to power supply board by turning power ON and testing for rated AC voltage at the AC input pin (pin L) on the power supply board. If readings are not to rated voltages, replace power supply board.
3 With power OFF, reconnect the optical assembly at J301.
Turn power ON and check voltages at J101.
J101 DC Voltage
GND-1 4.75 to 5.25
GND-3 11.4 to 12.6
GND-6 21.6 to 26.4
4 If any voltages are not correct, replace the power supply
board.
5 Turn scanner off. With power OFF, remove connector
J301 from the logic board. Turn power ON and check the voltages at J101 again. If readings are within specified ranges, replace the optical assembly, since the CCD
driver is faulty. 6 Turn scanner OFF and reconnect J301. 7 With power OFF, remove connector J311 from the logic
board. Turn power ON and check the voltages at J101
again. If readings are within specified ranges, replace the
drive motor. 8 Turn scanner OFF and reconnect J311. 9 With power OFF, remove connector J306 from the logic
board. 10 Turn power ON and check voltages at J101 again. If
readings are within specified ranges, replace the home
position sensor and/or home position sensor cable. 11 Turn scanner OFF and reconnect J306. 12 With power OFF, remove connector J309 from the logic
board. 13 Turn power ON and check voltages at J101 again. If
readings are within specified ranges, replace the LED
cable. If readings are not within specified ranges, replace
the logic board. 14 Turn scanner OFF and reconnect J309.
Troubleshooting Symptom Charts/General Troubleshooting - 5
Lamp does not light 1 Check connection at J402.
2 Remove the covers, glass, and optical assembly. With
power OFF, reconnect the optical assembly at J301. Turn
power ON and check voltages at J101.
J101 DC Voltage
GND-1 4.75 to 5.25
GND-3 11.4 to 12.6
GND-6 21.6 to 26.4
3 If any voltage is not correct, replace power supply board. 4 Connect J310 pin 2 to ground. Verify that scanner lamp
lights. If lamp does not light, replace logic board. 5 Connect J402 pin 2 on inverter board to ground. Verify
that scanner lamp lights. If lamp does not light, replace
inverter board. If lamp lights, replace optical assembly.
Lamp turns on, but scanner drive motor is not working
1 Make sure scanner optical assembly is unlocked. See
Additional Procedures chapter for information. 2 Check connections at J307 and J311. 3 Remove optical assembly and turn on scanner. If motor
works, make sure the glass is oriented correctly. Go to
symptom “Scanner does not find Home sensor”. 4 With scanner on, check voltages at connector J101.
J101 DC Voltage
GND-1 4.75 to 5.25
GND-3 11.4 to 12.6
GND-6 21.6 to 26.4
5 If any voltages are not correct, go to symptom “No LED,
no power” in this chapter. 6 Turn power off and check resistance in the drive motor by
measuring at connector J311.
J311 pins Resistance
1 and 2 about 17.3 ohms
3 and 4 about 17.3 ohms
7 If resistance is not correct, replace drive motor. If
resistance is correct, check connection at J311 and if it
is normal, replace logic board.
Troubleshooting Symptom Charts/General Troubleshooting - 6
Problem with lamp intensity checked or origin of scan area
Scanner does not find Home sensor; scanner drive motor does not move mirror, even when optical assembly is removed
When the Apple Color OneScanner Plug-in is moved to the Photoshop Acquire folder it doesn’t work. The Dispatch doesn’t work either.
When using the Automatic Document Feeder (ADF), the scan shows a blank page or a strange vertical pattern.
1 Make sure glass is oriented correctly and that nothing is
blocking the black strip or upper portion of the glass. 2 Replace glass.
1 Inspect mirror assembly on optical assembly for damage
to the home position flag. Replace optical assembly if
needed. 2 Replace home sensor (photo-interrupter). 3 Replace logic board.
The Apple Color OneScanner Plug-in must be left in it’s folder. You can make a copy of it, or an alias and put that in the Acquire folder. You cannot change the name of the original plug-in. It must keep the name “Apple Color OneScanner”.
Check to see if paper has been left on the flatbed. Before using the ADF, always check to see that the flatbed is empty.
Cannot fax multiple pages with the ADF.
ADF does not feed paper to scanner
Scan each page and merge them together before faxing them.
1 Check connection at document feeder connector cable. 2 Close document feeder cover completely. 3 Verify that document originals in the feeder are standard
office papers and do not exceed the maximum thickness of
2 mm (5/64 in) or 20 sheets. 4 Verify that document originals are free from
• Tears, perforations, or punch holes
• Curls or wrinkles
• Carbon backing or coarse texture
• Labels, tape, or glue
• Staples or clips
5 Replace logic board.
Troubleshooting Symptom Charts/Image Defects - 7

Image Defects

Image not correct, white only, black only, or grey.
1 Check SCSI cable connection. 2 Check whether scanning lamp is lighting. If not, go to
symptom “Lamp does not light” in this chapter. 3 With power off, remove connector J307. Turn on power
and check voltages at J101 on the power supply board.
J101 DC Voltage
GND-1 4.75 to 5.25
GND-3 11.4 to 12.6
GND-6 20.4 to 27.6
4 If these voltages are not present, go to symptom “No LED
(no power)” in this chapter. 5 Replace logic board. 6 Check connector at J301 and if it is normal, replace
optical assembly.
Troubleshooting Symptom Charts/Image Defects - 8
Image blurred 1 Use a soft, dry cloth to clean top of glass.
2 Check mirror for dust or obstructions. 3 Replace optical assembly.
A
Troubleshooting Symptom Charts/Image Defects - 9
Uneven image density or lines (horizontal)
A A
1 Use a soft, dry cloth to clean top of glass. 2 Check underside of glass to make sure the white plate is
intact. 3 Check connections at J301 and J310 on the logic board. 4 Replace logic board. 5 Replace optical assembly.
A
Troubleshooting Symptom Charts/Image Defects - 10
Uneven image density or lines (vertical)
A A
A
1 Use a soft, dry cloth to clean top of glass. 2 Check underside of glass to make sure the white plate is
intact. 3 Check mirrors for dust or obstructions. 4 Replace logic board. 5 Replace optical assembly.
A
Troubleshooting Symptom Charts/Image Defects - 11
Image is misaligned (vertical)
1 Make sure the mirror on the optical assembly is not
obstructed. 2 Replace optical assembly.
Troubleshooting Symptom Charts/Image Defects - 12
Image is distorted 1 Replace optical assembly.
2 Replace logic board.
Loading...
+ 61 hidden pages