Apple Color Onescanner 600.27 Service Manual

Page 1
K
Service Source

Color OneScanner 600/27

Page 2
K
Service Source

Basics

Apple Color OneScanner 600/27
Page 3

Overview

Color OneScanner 600/27
The Color OneScanner 600/ 27 is a compact, digital­image color scanner with a maximum mechanical resolution of 300 x 600 dpi.
Page 4
An optional accessory for the Color OneScanner 600/27 is an Automatic Document
Automatic Document Feeder
Feeder (ADF) with a 20­sheet capacity paper tray.
Page 5

Scanner Features

Features of the Color OneScanner 600/27 include the following:
• 300 x 600 dpi optical, 2400 x 2400 dpi interpolated, resolution for improved Optical Character Recognition (OCR) accuracy
• 27-bit scanning depth color that recognizes up to 134­million colors
• Support for PICT, TIFF, JPEG, EPS, BMP, and Photoshop; compatible with most popular word processing, presentation, image-editing, page layout, and web-authoring software for the Macintosh
• OneScanner Dispatcher software that integrates with popular applications and provides the tools to scan, edit, and archive images or documents; supports Drag and Drop
• Small desktop footprint of 16.3 in by 11.3 in
Page 6
• ColorSync for the closest possible color match between what is scanned, seen on the monitor, or printed
• Xerox TextBridge for converting scanned documents into editable text or HTML format for a Web page
• Optional 20-sheet capacity Automatic Document Feeder
Page 7

Scanner Operation

Clicking the icon at left launches a MoviePlayer animation sequence that shows the following scanning cycles:
• Flatbed scanning where the document remains stationary and the scanner lamp moves to scan from the front
• Automatic Document Feeder (ADF) scanning where the document moves and the scanner lamp remains in one position to scan from the front
Note:
Also shown in the animation sequence is Transparent Media Adapter (TMA) scanning where the document remains stationary and the TMA lamp moves to scan from the back. This type of scanning is available with the TMA option for the Apple Color OneScanner 1200/30. A TMA option is not available for the Apple Color OneScanner 600/27.
Page 8

Optical Assembly Handling Precautions

Issue
: The Color One Scanner 600/27 optical assembly is being damaged during removal.
Solution:
by the longer sides (see illustration on next page) so that the printed circuit board (CCD unit) on the underside will not be damaged. The CCD unit is a delicate part located on the front, or shorter side of the assembly. If a service provider grabs or touches the CCD unit while removing or replacing the scanner, the scanner may not function. In addition, new packing was designed for the scanner unit.
Note
Assembly in Take Apart.
Apple recommends handling the scanner assembly
: For additional information, refer to the Optical
Page 9
Hold or lift the optical assembly by the long sides,
CCD Unit
Mirrors
never by the shorter sides.
Caution:
Do not touch the printed circuit board (CCD Unit) or the mirrors.
Page 10
K
Service Source
Specifications
Color OneScanner 600/27
Page 11
Specifications Characteristics - 1

Characteristics

Scanner T ype

Scanner Resolution

Maximum Document Size

Speed

Interface

Flatbed, Single pass, 27-bit scanning
300 x 600 dpi 2400 x 2400 dpi interpolated
8.5 by 11.5 in.
8.5 by 14 in. with optional Automatic Document Feeder
Color: 20 seconds (US letter size) Monochrome: 10 seconds (US letter size)
SCSI-2
Page 12
Specifications Electrical - 2

Electrical

Line V oltage

Frequency

Power Consumption

100/120/200/220/240 VAC ± 10%
48–62 Hz ± 10
35 W (maximum)
Page 13
Specifications Physical - 3

Physical

Size

Weight

Height: 3.1 in. (79 mm) Width: 11.3 in. (287 mm) Depth: 16.3 in. (414 mm)
13.2 lb. (6 kg)
Page 14

Environmental

Temperature

Relative Humidity

50–90.5°F (10–32.5°C)
20–80% noncondensing
Page 15
K
Service Source

Troubleshooting

Color OneScanner 600/27
Page 16
Troubleshooting General/ - 1

General

The Symptom Charts included in this chapter will help you diagnose specific symptoms related to your product. Because cures are listed on the charts in the order of most likely solution, try the first cure first. Verify whether or not the product continues to exhibit the symptom. If the symptom persists, try the next cure. (Note: If you have replaced a module, reinstall the original module before you proceed to the next cure.)
For additional assistance, contact Apple Technical Support.
Page 17
Troubleshooting Wiring Diagram/ - 2

Wiring Diagram

CDD Drive Board
(Optical Assembly)
J201
1 2 3 4 5 6 7 8 9 10 11 12 13
YEL
YEL
YEL
YEL
YEL
YEL
YEL
YEL
YEL
YEL
YEL
YEL
Drive Motor
LED
1 2 3
J401
Inverter
Scanning Lamp (Optical Assembly)
Board
J402
1 2 3
BRN ORN RED YEL
RED BLK
RED BLU WHT
BRN BLK ORN BLK BLK BLU
J301
J311
A
1 2
A*
3
B
4
B*
J309
12+5V
GND
J310
1
+24V
2
GND
3
LON*
J307
1
+5V
2
DGND
3
+12V
4
AGND
5
24V GND
6
+24V
1 2 3 4 5 6 7 8 9 10 11 12 13
BGR
GND
+12V
+A5V
CPCKN
RSN
SPCKN
SHN
F2N
F1N
J306
1
HPSNS
2
GND
3
VCC
Logic Board
BRN YEL BLU
Home
Position
Sensor
1 2 3
WHT WHT
1 2 3 4 5 6
J101
Power Supply Board
Page 18
Troubleshooting Symptom Charts/Normal Startup Sequence (Flatbed Scanning) -

Symptom Charts

Normal Startup Sequence (Flatbed Scanning)

Important:
the startup sequence. Even when turned off, some computers will not allow the scanner’s normal startup sequence to begin if the SCSI cable is connected.
1 Power on 2 Power LED lights 3 Logic board self-tests 4 Lamp turns on 5 Optical assembly moves to home position sensor at top of
6 Lamp turns off, then on 7 Lamp intensity checked with reflection of white on back of
8 Origin of scan is determined by black strip on back of
9 Lamp moves about 3 mm down 10 Lamp moves back to home position sensor 11 Lamp turns off 12 Ready
Disconnect the scanner’s SCSI cable before beginning
glass
glass
glass

Startup Troubleshooting Tips

When scanner is turned on, there is a chattering sound and it will not scan.
When trying to scan from the Dispatch software, this message appears: “Unable to initialize the scanner driver. Either the scanner is not turned on, connected, or already in use by another application.”
The SCSI select switch doesn’t select the correct SCSI ID.
Unlock the scanner by opening the top cover and using a coin or slotted screwdriver to turn the locking mechanism, located at the top of the glass. unlock icon is at 90 degrees from the slot. See the Additional Procedures chapter for more information.
1 The most common cause is that the scanner was turned on
after the Macintosh. Always make sure the scanner is turned on, then turn on the Macintosh. Observe the INITs as the Macintosh starts up. The INIT for the scanner appears as a side view of the scanner. This is the driver loading.
2 If the scanner INIT does not appear, reinstall the scanner
driver. If the icon appears with an “X” through it, there is a SCSI problem.
3 Check the SCSI ID and cables.
The label may not be lined up correctly to the position of the switch. Put the switch in the 12 o’clock position and then count to the correct SCSI ID.
Note:
The arrow that points to the lock or
Page 19
Troubleshooting Symptom Charts/General Troubleshooting - 4

General Troubleshooting

No LED (no power) 1 Check external power cable and incoming voltage.
2 Remove the covers, glass, and optical assembly. Check AC
voltage to power supply board by turning power ON and testing for rated AC voltage at the AC input pin (pin L) on the power supply board. If readings are not to rated voltages, replace power supply board.
3 With power OFF, reconnect the optical assembly at J301.
Turn power ON and check voltages at J101.
J101 DC Voltage
GND-1 4.75 to 5.25
GND-3 11.4 to 12.6
GND-6 21.6 to 26.4
4 If any voltages are not correct, replace the power supply
board.
5 Turn scanner off. With power OFF, remove connector
J301 from the logic board. Turn power ON and check the voltages at J101 again. If readings are within specified ranges, replace the optical assembly, since the CCD
driver is faulty. 6 Turn scanner OFF and reconnect J301. 7 With power OFF, remove connector J311 from the logic
board. Turn power ON and check the voltages at J101
again. If readings are within specified ranges, replace the
drive motor. 8 Turn scanner OFF and reconnect J311. 9 With power OFF, remove connector J306 from the logic
board. 10 Turn power ON and check voltages at J101 again. If
readings are within specified ranges, replace the home
position sensor and/or home position sensor cable. 11 Turn scanner OFF and reconnect J306. 12 With power OFF, remove connector J309 from the logic
board. 13 Turn power ON and check voltages at J101 again. If
readings are within specified ranges, replace the LED
cable. If readings are not within specified ranges, replace
the logic board. 14 Turn scanner OFF and reconnect J309.
Page 20
Troubleshooting Symptom Charts/General Troubleshooting - 5
Lamp does not light 1 Check connection at J402.
2 Remove the covers, glass, and optical assembly. With
power OFF, reconnect the optical assembly at J301. Turn
power ON and check voltages at J101.
J101 DC Voltage
GND-1 4.75 to 5.25
GND-3 11.4 to 12.6
GND-6 21.6 to 26.4
3 If any voltage is not correct, replace power supply board. 4 Connect J310 pin 2 to ground. Verify that scanner lamp
lights. If lamp does not light, replace logic board. 5 Connect J402 pin 2 on inverter board to ground. Verify
that scanner lamp lights. If lamp does not light, replace
inverter board. If lamp lights, replace optical assembly.
Lamp turns on, but scanner drive motor is not working
1 Make sure scanner optical assembly is unlocked. See
Additional Procedures chapter for information. 2 Check connections at J307 and J311. 3 Remove optical assembly and turn on scanner. If motor
works, make sure the glass is oriented correctly. Go to
symptom “Scanner does not find Home sensor”. 4 With scanner on, check voltages at connector J101.
J101 DC Voltage
GND-1 4.75 to 5.25
GND-3 11.4 to 12.6
GND-6 21.6 to 26.4
5 If any voltages are not correct, go to symptom “No LED,
no power” in this chapter. 6 Turn power off and check resistance in the drive motor by
measuring at connector J311.
J311 pins Resistance
1 and 2 about 17.3 ohms
3 and 4 about 17.3 ohms
7 If resistance is not correct, replace drive motor. If
resistance is correct, check connection at J311 and if it
is normal, replace logic board.
Page 21
Troubleshooting Symptom Charts/General Troubleshooting - 6
Problem with lamp intensity checked or origin of scan area
Scanner does not find Home sensor; scanner drive motor does not move mirror, even when optical assembly is removed
When the Apple Color OneScanner Plug-in is moved to the Photoshop Acquire folder it doesn’t work. The Dispatch doesn’t work either.
When using the Automatic Document Feeder (ADF), the scan shows a blank page or a strange vertical pattern.
1 Make sure glass is oriented correctly and that nothing is
blocking the black strip or upper portion of the glass. 2 Replace glass.
1 Inspect mirror assembly on optical assembly for damage
to the home position flag. Replace optical assembly if
needed. 2 Replace home sensor (photo-interrupter). 3 Replace logic board.
The Apple Color OneScanner Plug-in must be left in it’s folder. You can make a copy of it, or an alias and put that in the Acquire folder. You cannot change the name of the original plug-in. It must keep the name “Apple Color OneScanner”.
Check to see if paper has been left on the flatbed. Before using the ADF, always check to see that the flatbed is empty.
Cannot fax multiple pages with the ADF.
ADF does not feed paper to scanner
Scan each page and merge them together before faxing them.
1 Check connection at document feeder connector cable. 2 Close document feeder cover completely. 3 Verify that document originals in the feeder are standard
office papers and do not exceed the maximum thickness of
2 mm (5/64 in) or 20 sheets. 4 Verify that document originals are free from
• Tears, perforations, or punch holes
• Curls or wrinkles
• Carbon backing or coarse texture
• Labels, tape, or glue
• Staples or clips
5 Replace logic board.
Page 22
Troubleshooting Symptom Charts/Image Defects - 7

Image Defects

Image not correct, white only, black only, or grey.
1 Check SCSI cable connection. 2 Check whether scanning lamp is lighting. If not, go to
symptom “Lamp does not light” in this chapter. 3 With power off, remove connector J307. Turn on power
and check voltages at J101 on the power supply board.
J101 DC Voltage
GND-1 4.75 to 5.25
GND-3 11.4 to 12.6
GND-6 20.4 to 27.6
4 If these voltages are not present, go to symptom “No LED
(no power)” in this chapter. 5 Replace logic board. 6 Check connector at J301 and if it is normal, replace
optical assembly.
Page 23
Troubleshooting Symptom Charts/Image Defects - 8
Image blurred 1 Use a soft, dry cloth to clean top of glass.
2 Check mirror for dust or obstructions. 3 Replace optical assembly.
A
Page 24
Troubleshooting Symptom Charts/Image Defects - 9
Uneven image density or lines (horizontal)
A A
1 Use a soft, dry cloth to clean top of glass. 2 Check underside of glass to make sure the white plate is
intact. 3 Check connections at J301 and J310 on the logic board. 4 Replace logic board. 5 Replace optical assembly.
A
Page 25
Troubleshooting Symptom Charts/Image Defects - 10
Uneven image density or lines (vertical)
A A
A
1 Use a soft, dry cloth to clean top of glass. 2 Check underside of glass to make sure the white plate is
intact. 3 Check mirrors for dust or obstructions. 4 Replace logic board. 5 Replace optical assembly.
A
Page 26
Troubleshooting Symptom Charts/Image Defects - 11
Image is misaligned (vertical)
1 Make sure the mirror on the optical assembly is not
obstructed. 2 Replace optical assembly.
Page 27
Troubleshooting Symptom Charts/Image Defects - 12
Image is distorted 1 Replace optical assembly.
2 Replace logic board.
Page 28
K
Service Source

T ak e Apart

Color OneScanner 600/27
Page 29
Take Apart Top Cover with Hinge - 1

Top Cover with Hinge

Top Cover with Hinge
No preliminary steps are required before you begin this procedure.
Page 30
Take Apart Top Cover with Hinge - 2
Lift the top cover straight off the scanner.
Top Cover with Hinge
Page 31
Take Apart Glass Cover - 3

Glass Cover

Before you begin, remove
Glass Cover
the top cover with hinge.
Caution:
precautions in Bulletins/ Safety.
Review the ESD
Page 32
Take Apart Glass Cover - 4
1 Using a jeweler’s flat-
blade screwdriver, release the two glass cover latches.
2 While pressing the
power switch, carefully lift off the glass cover.
Power Switch
Latch
Caution:
When removing the glass cover assembly, make sure you don’t damage the LED cable.
Page 33
Take Apart Glass Cover - 5
3 Raise the glass cover
assembly to 90 degrees
LED Cable
and disconnect the LED cable by pushing the LED toward the top of the glass cover.
4 Remove the glass cover
from the scanner.
Glass Cover
Caution:
When the glass cover is removed, do not tilt the scanner on its side, or the glass may slip off.
Page 34
Take Apart Glass Cover - 6
5 Grasp the glass by its
edges, and taking care not to bend the glass holder clips, slightly lift the glass and rotate it clockwise to release it from the glass holder clips.
Handle the glass by its edges and place it in a clean area.
Glass Holder Clip
Glass Holder Clip
Glass
Page 35
Take Apart Optical Assembly - 7

Optical Assembly

Optical Assembly
Before you begin, remove the following:
• Top cover with hinge
• Glass cover assembly
Caution
precautions in Bulletins/ Safety.
1 Make sure
: Review the ESD
• Scanner power is off
• Power cord is
connected
• SCSI cable is
disconnected
Page 36
Take Apart Optical Assembly - 8
2 Set the SCSI ID switch to
7 (terminator off position).
3 Switch on the scanner
power.
Wait for the startup sequence to finish and the lamp to turn off. (For a description of the normal startup sequence, refer to the Troubleshooting chapter.)
SCSI ID Switch
4 Set the SCSI ID switch to
0 (terminator on position).
Page 37
Take Apart Optical Assembly - 9
Screw
Screw
Mirror
Screw
Screw
Screw
Screw
5 Set the SCSI ID switch
back to 7, then back to 0 and finally back to 7.
6 After about 10 seconds,
the lamp and mirror will move. When the mirror has reached the position shown, turn off the scanner.
7 Using a Phillips
screwdriver, remove
• Four screws and
lockwashers
• Two screws at rear
feet
Page 38
Take Apart Optical Assembly - 10
8 Using a needlenose
pliers, carefully remove connector J402 from the logic board.
J402
Page 39
Take Apart Optical Assembly - 11
9 Carefully lift the optical
assembly and remove
Longer Side
connector J301 from the inverter board.
J301
CCD Unit
Caution:
scanner assembly by the longer sides so that the
Handle the
printed circuit board (CCD unit) on the underside will not be damaged.
Page 40
Take Apart Optical Assembly - 12
10
Note:
Do not touch the
Mirror
Optical
Assembly
mirror or the printed circuit board (CCD unit) on the optical assembly.
Remove the optical assembly from the scanner.
CCD Unit
Page 41
Take Apart LED Cable - 13

LED Cable

LED Cable
Before you begin, remove the following:
• Top cover
• Glass cover assembly
• Optical assembly
Caution
precautions in Bulletins/ Safety.
: Review the ESD
Page 42
Take Apart LED Cable - 14
1 Disconnect connector
Tie Wrap
Cable Clip
J309
J309 from the logic board.
2 Remove the cable from
the cable clip and cut the tie wrap.
Page 43
Take Apart LED Cable - 15
3 Remove the tape and LED
cable from the bottom
LED Cable
Tape
case.
Page 44
Take Apart Inverter Board - 16

Inverter Board

Inverter Board
Before you begin, remove the following:
• Top cover
• Glass cover assembly
• Optical assembly
Caution
precautions in Bulletins/ Safety.
.
: Review the ESD
Page 45
Take Apart Inverter Board - 17
1 Disconnect connector
J402
J402 from the inverter board.
Page 46
Take Apart Inverter Board - 18
2 Using a pair of
needlenose pliers, squeeze the card spacer tabs and remove the inverter board.
Card Spacer
Page 47
Take Apart Drive Motor and Bracket - 19

Drive Motor and Bracket

Before you begin, remove the following:
• Top cover
• Glass cover assembly
• Optical assembly
Drive Motor
Caution
precautions in Bulletins/ Safety.
: Review the ESD
Page 48
Take Apart Drive Motor and Bracket - 20
1 Remove connector J311
from the logic board.
2 Remove the cable from
the cable clip.
J311 Cable Clip
Page 49
Take Apart Drive Motor and Bracket - 21
3 Remove the two screws
and washers.
4 Remove the drive motor
and bracket from the bottom case.
Screw
Drive Motor
Screw
Page 50
Take Apart Drive Motor and Bracket - 22
5 If necessary, lift off and
remove the gear from the motor.
Spindle
Replacement Note:
Make sure the gear is lined up with the flat side of the drive motor spindle when reinstalling.
Drive Motor Gear
Page 51
Take Apart Drive Motor and Bracket - 23
6 Carefully remove the
drive motor damper.
Drive Motor Bracket
7 Using a Phillips
screwdriver, remove the two screws from the drive motor bracket.
8 Remove the drive motor
from the bracket.
Drive Motor
Drive Motor Damper
Page 52
Take Apart Power Supply Board - 24
Power Supply

Power Supply Board

Board
Before you begin, remove the following:
• Top cover
• Glass cover assembly
• Optical assembly
• Inverter board
Caution
precautions in Bulletins/ Safety.
Note:
board before returning the power supply to Apple.
: Review the ESD
Remove the inverter
Page 53
Take Apart Power Supply Board - 25
1 Cut the tie wraps and
remove connector J307 from the logic board.
2 Remove the cables from
the cable clip.
J307Logic Board
Cable Clip
Page 54
Take Apart Power Supply Board - 26
3 Slide the power switch
up and out of the bottom case.
4 Remove the two screws
that hold the power receptacle.
Screw
Power Switch
Screw
Power Receptacle
Page 55
Take Apart Power Supply Board - 27
5 Remove the two
Screw
mounting screws.
6 Remove the ground
screw and lockwasher.
Power Supply
Board
7 Remove the power
supply board from the scanner.
Ground Screw
Screw
Page 56
Take Apart Logic Board - 28

Logic Board

Before you begin, remove the following:
Logic Board
• Top cover
• Glass cover assembly
• Optical assembly
• Drive Motor
Caution
precautions in Bulletins/ Safety.
: Review the ESD
Page 57
Take Apart Logic Board - 29
1 Disconnect the following
cables from the logic board:
• J306
• J307
• J309
J306
J309
J307
J310
• J310
Page 58
Take Apart Logic Board - 30
2 Using a Phillips
screwdriver, remove the two mounting screws from the SCSI connector.
3 Using a hex driver,
remove the two mounting screws from the interface connector.
SCSI ConnectorInterface Connector
Page 59
Take Apart Logic Board - 31
4 Remove the corner
screw from the logic
Logic Board
Screw
board.
Page 60
Take Apart Logic Board - 32
5 Using needlenose pliers,
squeeze together the card
Card Spacer
Logic Board
spacers and lift off the logic board.
Page 61
Take Apart Logic Board - 33
6 Remove the shield plate
Logic Board
Shield Plate
from the logic board.
Page 62
Take Apart Home Position Sensor (Photo-Interrupter) and Cable - 34
Home Position
Home Position Sensor (Photo-Interrupter)
Cable
Sensor (Photo­Interrupter) and Cable
Before you begin, remove the following:
• Top cover
• Glass cover assembly
• Optical assembly
Caution
precautions in Bulletins/ Safety.
: Review the ESD
Page 63
Take Apart Home Position Sensor (Photo-Interrupter) and Cable - 35
1 Remove the cable from
connector J306 on the
Home Position Sensor
Cable
logic board and the connector on the home position sensor (photo­interrupter).
Logic Board
Page 64
Take Apart Home Position Sensor (Photo-Interrupter) and Cable - 36
2 Press in the two latches
and lift up to remove the home position sensor from the bottom case.
Home Position
Sensor
Page 65
Take Apart Feet - 37

Feet

Before you begin, remove
Rear Foot
Rear Foot
the following:
• Top cover
• Glass cover assembly
• Optical assembly
Front Foot
Front Foot
Caution
precautions in Bulletins/ Safety.
: Review the ESD
Page 66
Take Apart Feet - 38
1 Slide the rear foot off of
the bottom case. Repeat for other rear foot.
Rear Foot
Page 67
Take Apart Feet - 39
2 Press down and unlatch
the front foot from the bottom case. Repeat for other front foot.
Bottom Case
Front Foot
Page 68
Take Apart Automatic Document Feeder - 40
Automatic

Automatic Document Feeder

Document Feeder
No preliminary steps are required before you begin this procedure.
Caution
precautions in Bulletins/ Safety.
: Review the ESD
Page 69
Take Apart Automatic Document Feeder - 41
1 Lift the document feeder
straight off the scanner.
Document Feeder
Page 70
Take Apart Automatic Document Feeder - 42

Paper Separator

1 Lift up the top cover of
Document Feeder Top Cover
the document feeder.
Page 71
Take Apart Automatic Document Feeder - 43
2 Do not pull on the
rubber piece on the paper separator. It is held in place by a metal clip and will come off if pulled.
Push down and press forward on the paper separator.
3 Remove the paper
separator.
Rubber Piece
Paper Separator
Page 72
Take Apart Automatic Document Feeder - 44
Delivery Guide
and Deflector
Document Feeder
Delivery Guide and Deflector
1 Turn the document
feeder over.
Page 73
Take Apart Automatic Document Feeder - 45
2 Press in the two latches
and swing out the
Delivery Guide
Latch
and Deflector
Latch
delivery guide and deflector.
Page 74
Take Apart Automatic Document Feeder - 46
3 Remove the delivery
guide and deflector.
Delivery Guide
and Deflector
Page 75
Take Apart Automatic Document Feeder - 47
4 Remove the delivery
guide from the deflector.
Delivery Guide
Deflector
Page 76
Take Apart Automatic Document Feeder - 48
Replacement Note:
Tab
Before installing the deflector back into the document feeder, make
Tab
sure the two holes on the delivery guide line up with the two tabs on the deflector.
Page 77
Take Apart Automatic Document Feeder - 49
Replacement Note: Slip the delivery guide back under the plastic sheet
Plastic Sheet
Delivery Guide
on the document feeder and snap the deflector in place.
Page 78
K
Service Source

Additional Procedures

Color OneScanner 600/27
Page 79
Additional Procedures Unlocking the Scanner - 1

Unlocking the Scanner

Before you begin, remove the top cover with hinge.
Lock
Page 80
Additional Procedures Unlocking the Scanner - 2
Using a coin or a flat-blade
Lock
screwdriver, rotate the lock to the unlocked position.
Unlocked
Position
Page 81
Additional Procedures Changing the SCSI ID - 3

Changing the SCSI ID

No preliminary steps are required before you begin this procedure.
SCSI Switch
Caution:
precautions in Bulletins/ Safety.
Review the ESD
Page 82
Additional Procedures Changing the SCSI ID - 4
There are two sets of SCSI ID numbers, depending if the scanner has an external SCSI terminator installed:
• The numbers on the left are with SCSI termination turned off. Use these numbers if there is an external SCSI terminator.
• The numbers on the right are with SCSI termination turned on. Use these numbers if there is no external
SCSI Termination
Off
SCSI Termination
On
terminator.
Page 83
Additional Procedures Changing the SCSI ID - 5
Turn the switch to the desired number.
SCSI ID Switch
Page 84
Additional Procedures Moving the Optical Assembly to Service Position - 6
Moving the Optical Assembly
Optical Assembly
to Service Position
Before you begin, remove the top cover with hinge.
1 Make sure
• Scanner power is off
• Power cord is connected
• SCSI cable is disconnected
Page 85
Additional Procedures Moving the Optical Assembly to Service Position - 7
2 Set the SCSI ID switch to
7 (terminator off position).
3 Switch on the scanner
power.
Wait for the startup sequence to finish and the lamp to turn off. (For a description of the normal startup sequence, refer to the Troubleshooting chapter.)
SCSI ID Switch
4 Set the SCSI ID switch to
0 (terminator on position).
Page 86
Additional Procedures Moving the Optical Assembly to Service Position - 8
5 Set the SCSI ID switch
Mirror
Optical Assembly
back to 7, then back to 0 and finally back to 7.
6 The optical unit will now
move. When the mirror has reached the position where it is between the set of four screws on the bottom, turn off the scanner.
Page 87
K
Service Source
Exploded V ie w
Color OneScanner 600/27
Page 88

Exploded View 1

Document Feeder, Whole Unit
661-1119
Delivery Guide Sheet, ADF 922-2048
Cable Sensor 922-1937
Photo-
Interrupter 922-1353
Paper Separator, ADF
922-2047
Deflector, ADF
922-2049
Cover, Top w/Hinge
922-1930
Cover, Glass
922-1932
Glass w/Scale 922-2024
Kit, Foot 076-0535
Gear, Motor (pkg. of 5)
922-2042
(pkg. of 5)
Motor, Drive 922-1938
Bracket, Motor
922-2046
Pad, Damper, Motor 922-2045
Plate, Shield
922-1934
Logic Board
661-1083
Cable, LED 922-1935
Holder, Glass (pkg. of 10)
922-1933
Optical
661-1084
Power Supply
661-1085
Assembly
Inverter Board
922-1936
Loading...