APC AP7900 User manual

4 (1)
APC AP7900 User manual

Installation

Switched Rack Power

Distribution Unit

This manual is available in English on the enclosed CD.

Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM verfügbar.

Este manual está disponible en español en el CD-ROM adjunto. Ce manuel est disponible en français sur le CD-ROM ci-inclus. Questo manuale è disponibile in italiano nel CD-ROM allegato.

CD-ROM

Instrukcja Obsługi w jezyku polskim jest dostepna na CD.

Данное руководство на русском языке имеется на прилагаемом компакт-диске.

O manual em Português está disponível no CD-ROM em anexo.

Bu kullanim kilavuzunun Türkçe'sä, äläxäkte gönderälen CD äçeräsände mevcuttur.

Contents

Preliminary Information. . . . . . . . . . . . . . . . . . .1

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Display interface . . . . . . . . . . . . . . . . . . . . . . . 1 Additional documentation . . . . . . . . . . . . . . . 2 Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Receiving inspection . . . . . . . . . . . . . . . . . . . 2 Please recycle . . . . . . . . . . . . . . . . . . . . . . . . . 2

Install the Rack PDU . . . . . . . . . . . . . . . . . . . . .3

Attach the cord retention trays . . . . . . . . . . . 3 Attach cords to the tray . . . . . . . . . . . . . . . . . 3 Mounting options . . . . . . . . . . . . . . . . . . . . . . 3 Toolless mounting . . . . . . . . . . . . . . . . . . . . . 4 Bracket mounting (vertical) . . . . . . . . . . . . . . 5 Bracket mounting (horizontal). . . . . . . . . . . . 6

Display Interface Operation . . . . . . . . . . . . . . .8

Quick Configuration. . . . . . . . . . . . . . . . . . . . . .9

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 TCP/IP configuration methods. . . . . . . . . . . . 9 Device IP Configuration Wizard. . . . . . . . . . . 9 BOOTP & DHCP configuration. . . . . . . . . . . 10 Local access to the control console . . . . . . 12 Remote access to the control console . . . . 13 Control console. . . . . . . . . . . . . . . . . . . . . . . 14

Access a Configured PDU. . . . . . . . . . . . . . . .15

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Web interface. . . . . . . . . . . . . . . . . . . . . . . . . 15 Telnet and SSH . . . . . . . . . . . . . . . . . . . . . . . 15 SNMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 FTP and SCP . . . . . . . . . . . . . . . . . . . . . . . . . 18 Managing the security of your system . . . . 18

Recover From a Lost Password . . . . . . . . . . .19 How to Update Firmware . . . . . . . . . . . . . . . . .20

Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21

Terms of warranty. . . . . . . . . . . . . . . . . . . . . 21 Non-transferable warranty . . . . . . . . . . . . . . 21 Exclusions . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Warranty claims . . . . . . . . . . . . . . . . . . . . . . 22

Life-Support Policy . . . . . . . . . . . . . . . . . . . . .23

General Policy . . . . . . . . . . . . . . . . . . . . . . . . 23 Examples of life-support devices . . . . . . . . 23

Switched Rack Power Distribution Unit

i

Preliminary Information

Features

This booklet provides information on installing and operating Switched Rack Power Distribution Units (PDUs). Each PDU is a stand-alone, networkmanageable device that allows programmable control of power outlets through its Web, Telnet, SNMP, SSH, or InfraStruXure® Manager interfaces.

Using the Switched Rack PDU, you can do several things:

Set the following values for each outlet independently:

Power On Delay

Power Off Delay

Reboot Duration

Set up power sequencing to avoid an in-rush of current at system start-up.

Manage access to outlets through the following four types of user accounts:

Administrator

Device User

Outlet User

Read-Only User

Upgrade the Switched Rack PDU firmware without affecting the outlet state.

Provide an independent Outlet User account for each outlet.

Import the event and data logs into a spreadsheet application.

Protect data using the advanced security protocols of the Switched Rack PDU.

Monitor the aggregate current draw of the Switched Rack PDU, which helps avoid overloaded circuits.

Note. The Switched Rack PDU does not provide power protection. Therefore, American Power Conversion (APC®) does not recommend plugging the unit directly into any unprotected power source, such as a wall outlet.

Display interface

The display interface on the Switched Rack PDU shows the aggregate current being used by the PDU and its attached devices. An alarm occurs if the aggregate current is above the high threshold value or below the low threshold value that you configure.

1

Switched Rack Power Distribution Unit

Additional documentation

The Switched Rack PDU User’s Guide is available on the supplied CD or on the APC Web site: www.apc.com.

The User’s Guide contains additional information about the following topics related to the Switched Rack PDU:

Management interfaces

User accounts

Customizing setup

The APC Device IP Configuration Wizard

Configuration utilities

File transfers

 

 

Note. For security information, see the

 

 

Security Handbook, available on the

 

 

Utility CD or on the APC Web site:

 

 

www.apc.com.

Inventory

 

 

 

 

 

Quantity

Item

 

 

 

 

1

Configuration cable (940-0144)

 

 

 

 

3

Cord retention trays (with 12

 

 

flat-head screws and 24 wire ties)

 

 

 

 

1

APC Switched Rack PDU Utility CD

 

 

 

 

2

Vertical mounting brackets (with 4

 

 

pan-head screws)

 

 

 

 

1

Warranty registration card

 

 

 

Receiving inspection

Inspect the package and contents for shipping damage and make sure that all parts were sent. Report any damage immediately to the shipping agent and report missing contents, damage, or other problems immediately to APC or your APC reseller.

Please recycle

The shipping materials are recyclable. Please save them for later use, or dispose of them appropriately.

Switched Rack Power Distribution Unit

2

Install the Rack PDU

Attach the cord retention trays

Attach the cord retention trays to the Switched Rack PDU, using four flat-head screws (provided) per tray.

Caution. Use only the supplied screws.

Attach cords to the tray

Attach each cord to the tray by looping the cord and securing it to the tray using a wire tie (provided).

Note. Each cord must be secured to the tray so that you can unplug it from the PDU without removing the wire tie.

Note. When installing the PDU, ensure that the power cord plug is accessible and that the PDU is connected to a grounded outlet.

Mounting options

You can install the PDU in one of two ways: using toolless mounting pegs (provided) or mounting brackets (provided). The 1-U and 2-U horizontal PDUs must be mounted using the horizontal mounting brackets.

Vertical Mounting.

To install the Switched Rack PDU using the

toolless mounting method, install it in the rear of a NetShelter® VX or SX enclosure, in the cable channel directly behind the rear vertical mounting rails.

To install the Switched Rack PDU using the mounting brackets, install it on a vertical mounting rail of your rack or enclosure.

3

Switched Rack Power Distribution Unit

Horizontal Mounting.

To install the PDU using the horizontal mounting brackets, install the brackets on the PDU and then attach the PDU to the rack using cage nuts (provided with your enclosure).

Toolless mounting

Note. This option may not be available with all enclosures.

1.Slide both mounting pegs into the holes located in the channel in the rear panel of the enclosure.

2.Snap the Rack PDU into place by pushing it downward until it locks into position.

Note. You can mount two PDUs on one or both sides of the enclosure by using the toolless mounting method.

Switched Rack Power Distribution Unit

4

Bracket mounting (vertical)

To mount the Rack PDU vertically in a NetShelter or any standard EIA-310 rack or enclosure:

1.Attach the vertical-mounting brackets to the PDU.

Caution. Use only the supplied screws.

2.Install the Rack PDU on a vertical mounting rail in your rack or enclosure using the screws and cage nuts supplied with your enclosure.

5

Switched Rack Power Distribution Unit

Bracket mounting (horizontal)

You can order a rack-mount bracket kit (AR8116BLK) from APC. The brackets attach to the Switched Rack PDU in either of two directions, shown in the figures in step 1. Consider the orientation of the Switched Rack PDU in the enclosure before attaching the brackets. A recessed orientation allows the Switched Rack PDU to be mounted even with the enclosure; a raised orientation allows you to route cables through the channel.

Caution. Use only the supplied screws.

1.Attach two brackets to the rear of the Switched Rack PDU, using two pan-head screws (provided in the bracket kit) for each bracket.

Recessed orientation

Raised orientation

Note. You can mount two PDUs on one side of the enclosure by using the raised orientation.

Switched Rack Power Distribution Unit

6

Loading...