30GX-4SB
30GX080-265
AIR-COOLED LIQUID CHILLER
ÐPERFORMANCE DATA
ÐCERTIFIED DIMENSION PRINT
ÐFIELD WIRING DIAGRAM
R 1997 Carrier Corporation · Syracuse, New York 13221
Form 30GX-4SB Supersedes 30GX-3SB |
Printed in U.S.A. |
12-97 |
Catalog No. 513-450 |
Date: |
Supersedes: |
30GX080-265 |
30GX |
Rev.: |
|
|
AIR-COOLED LIQUID CHILLER |
-4SB |
|
|
|
|
||
|
|
|
|
|
JOB NAME: |
LOCATION: |
|
|
|
BUYER: |
|
BUYER P.O. # |
CARRIER # |
|
UNIT NUMBER: |
MODEL NUMBER: |
|
|
|
|
|
|
|
|
PERFORMANCE DATA CERTIFIED BY: |
|
DATE: |
|
DESCRIPTION
Packaged air-cooled liquid chiller factory wired, piped, and charged with HFC-134a. Upward discharge air¯ow minimizes directional sound and dissipates heat away from surrounding areas.
FEATURES
Cooler is mechanically cleanable ``¯ooded'' shell-and-tube type |
Condenser fan motors are totally enclosed 3-phase with perma- |
|
with removable heads. It is tested and stamped in accordance |
nently lubricated bearings and Class F insulation (except speed |
|
with ASME Code for a refrigerant working side pressure of |
control motors). |
|
220 psig (1517 kPa) and a maximum ¯uid side pressure of |
Each refrigerant circuit includes oil separator, high side pressure |
|
300 psig (2068 kPa) (250 psig [1724 kPa] in Canada) and is |
||
relief device, liquid and discharge line shutoff valve, ®lter drier, |
||
insulated with 3¤4-in. (19 mm) closed-cell polyvinyl chloride foam. |
||
moisture indicating sight glass, expansion/level control device. |
||
Cooler can be equipped with electric heater to help protect against |
||
Microprocessor control includes keypad with diagnostic display |
||
cooler freeze-up (use of inhibited glycol anti-freeze recommended |
||
displaying set points, time, system status (including temperatures, |
||
for freeze protection). |
||
pressures and % loading) and the alarm conditions. |
||
Compressor is semi-hermetic twin screw design with refrigerant |
||
Automatic compressor lead/lag. |
||
gas cooled motor and integral oil ®lter and discharge gas muffler. |
||
Capacity control based on leaving chilled water temperature with |
||
Complete thermal and electrical protection is provided. |
||
return water temperature sensing. |
||
Air-cooled condenser is constructed of ®ns mechanically bonded |
||
7-Day time scheduling of pump(s) and chiller. |
||
to seamless copper tubes. Coils are leak and pressure tested at |
||
60-Hz Models: 080, 090, 106, 115, 125, 136, 151, 161, 176, 206, |
||
450 psig (3103 kPa). |
||
226, 251, and 265. |
||
Condenser fans are direct driven 11-blade, shrouded axial type, |
||
50-Hz Models: 080, 090, 105, 106, 115, 125, 136, 150, 160, 161, |
||
statically and dynamically balanced, discharging air vertically |
||
175, 205, 225, 226, 250, and 265. |
||
upward, protected by coated steel wire safety guards. |
||
|
PERFORMANCE DATA
UNIT |
|
|
|
COOLER |
|||||||||||||||
Capacity |
|
|
|
|
|
|
|
|
|
|
Cooler Fluid |
|
|
|
|
|
|||
Compressor Input Power |
|
kW |
Entering Fluid Temperature |
|
|||||||||||||||
Unit Input Power |
|
kW |
Leaving Fluid Temperature |
|
|||||||||||||||
Minimum Outdoor Operating Temperature |
|
|
|
|
Flow Rate |
|
|
|
|||||||||||
Capacity Control Steps |
|
|
|
|
|
Pressure Drop |
|
|
|||||||||||
Minimum Capacity % |
|
|
% |
|
Fouling Factor |
|
|||||||||||||
EER |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
Entering Air Temperature |
|
|
|
|
|
|
|
|
|
|
|
||||||||
Weight |
|
|
|
|
|
|
|
|
|
|
|
ELECTRICAL DATA
Power Supply to Unit |
|
|
Volts |
|
|
|
Ph |
|
|
|
|
|
Hz |
Control Circuit Fuse Amps |
|
Amps |
||||||
Power Supply to Control Circuit |
|
|
Volts |
|
|
Ph |
|
|
|
|
Hz |
Maximum Instantaneous Current Flow |
|
Amps |
||||||||
Minimum Amps Circuit 1 |
|
|
|
|
|
|
|
|
|
|
|
|
Amps |
Minimum Amps Circuit 2 |
|
Amps |
||||||
Maximum Fuse Amps Circuit 1 |
|
|
|
|
|
|
|
|
|
|
|
Amps |
Maximum Fuse Amps Circuit 2 |
|
Amps |
OPTIONS
M M
M M
M M
M M
2
CUT ALONG DOTTED LINE CUT ALONG DOTTED LINE
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
CERTIFIED DIMENSION PRINT
3
4
CERTIFIED DIMENSION PRINT