Xylem MJK 1100, MJK2100, MJK3100 User Manual

0 (0)
Xylem MJK 1100, MJK2100, MJK3100 User Manual

Manual

MJK 1100 / 2100 / 3100

Submersible Hydrostatic Level Transmitters

M275US0205

As our products are developed continuously we reserve the right to make any

 

change in the dimensions and the specifications.

MJK Automation A/S

Byageren 7 DK-2850 Nærum Denmark

Tel.: (+45) 45 56 06 56 Fax: (+45) 45 56 06 46 mjk@mjk.com www.mjk.com

Manual

General

Model 1100

Model 2100

Model 3100

 

Nominal pressure

Nominal pressure

Nominal pressure

 

range 0 - 10 ft,

range 0 - 10 ft,

range 0 - 1 ft,

 

0 - 30 ft, 0 - 100 ft.

0 - 30 ft, 0 - 100 ft.

0 - 3 ft, 0 - 10 ft.

 

Other ranges

Other ranges

Other ranges

 

available; see data

available; see data

available; see data

 

sheet.

sheet.

sheet.

Level measuring with a pressure transmitter is done by immersing a transmitter in the liquid. The transmitter measures the hydrostatic pressure and generates a current signal that is proportional with the hydrostatic pressure and thus proportional with the liquid level.

The MJK Submersible Hydrostatic Level Transmitters are all designed to generate a 2-wire (passive) 4 - 20 mA signal with a 10 - 30 V DC supply.

Safety instructions

1: Read this manual carefully.

 

2: Be aware of the environment on the

 

installation site. Wear neseccary protec-

 

tive equipment and follow all current

 

safety regulations.

3:MJK Pressure Transmitters must not be used in explosion hazarduous areas.

4:MJK Pressure Transmitters must not be submerged into flammable liquids.

Product identification and It is very important for the overall measuring pressure ranges accuracy that the pressure transmitter has

the correct pressure range.

Check that the item(s) delivered corresponds to the ordered item(s) by means of the information on the label on the packing:

Shown below is the label for a model 1100 pressure transmitter, range 0-10 ft:

On the model 1100 transmitter, all the standard pressure ranges together with the corresponding order numbers are printed on a label on the transmitter housing. The pressure range can be determined by comparing the order number impressed in the steel housing (together with the serial number) with the numbers on the label.

On model 2100 and 3100 transmitters, the actual pressure range is ticked off on the label on the housing.

 

Item number

 

Pressure range

 

Item description

 

Serial number

The same information plus cable length is printed on a similar label tagged onto the transmitter cable.

For all verstions the pressure range can be determined through the serial number.