Xylem IM234 User Manual

INSTRUCTION MANUAL
IM234
Moisture Sensor Relay
A 5VDC Power Supply is required for operation of Moisture Sensor Relay
• Connections to Aquavar SOLO • Connections to S-Drive and SPD
• Connections to Aquavar ABII (AquaBoost II)
INSTALLATION AND OPERATION MANUAL FOR 9K585
DANGER
WARNING
CAUTION
WARNING
WARNING
1: SAFETY INSTRUCTIONS
WARNING
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR PROPERTY DAMAGE, READ AND FOLLOW ALL SAFETY INSTRUCTIONS IN MANUAL AND ON EQUIPMENT.
THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND OPERATION OF THIS UNIT AND MUST BE KEPT WITH THE UNIT.
This is a SAFETY ALERT SYMBOL. When you see this symbol on the pump, the controller or in the manual, look for one of the following signal words and be alert to the potential for personal injury or property damage.
Warns of hazards that WILL cause serious personal injury, death or major property damage.
Warns of hazards that CAN cause serious personal injury, death or major property damage.
Warns of hazards that CAN cause personal injury or property damage.
NOTICE: INDICATES SPECIAL INSTRUCTIONS WHICH ARE VERY IMPORTANT AND MUST BE FOLLOWED.
THOROUGHLY REVIEW ALL INSTRUCTIONS AND WARNINGS PRIOR TO PERFORMING ANY WORK ON THIS CONTROLLER.
MAINTAIN ALL SAFETY DECALS.
Disconnect and lockout electrical power before installing or servicing any
electrical equipment.
ELECTROCUTION HAZARD.
CONTROLLER INPUT GROUND TERMINAL (GND) AND ALL EXPOSED METAL PIPING, INCLUDING PRESSURE TRANSDUCER CASE, MUST BE CONNECTED TO THE SERVICE ENTRANCE GROUND TERMINAL.
All electrical work must be performed
by a qualified technician. Always follow the National Electrical Code (NEC), or the Canadian Electrical Code, as well as all local, state and provincial codes. Code questions should be directed to your local electrical inspector. Failure to follow electrical codes and OSHA safety standards may result in personal injury or equipment damage. Failure to follow manufacturer’s installation instructions may result in electrical shock, fire hazard, personal injury or death, damaged equipment, unsatisfactory performance, and may void manufacturer’s warranty.
5VDC MOISTURE SENSOR RELAY
5VDC MOISTURE SENSOR RELAY
MODEL #9K585
INSTALLATION INSTRUCTIONS
The Sensor can detect the presence of water and provide a relay output for signal or control of an external device. The switch operates on 5 Volts DC and functions as a Normally Closed Sensor, for a Closed Loop system. The Red and Balck wires power the switch while the White and Green wires are the relay output wires.
For installation to an alarm panel, the Red wire is connected to the positive side of a 5 Volt supply and the Black wire is connected to the negative. The Green and White wires can then be connected to any pre-selected Closed Loop zone. A resistor can be connected in series with either the Green or White wire for those panels that require end-of-line resistance.
After installation these units should be tested with a damp sponge or paper towel and inspected annually. If there is any corrosion or damage the sensor should be replaced.
SPECIFICATIONS
Power Requirements:
Operating Voltage 5 Volts DC Operating Current 10 mA
Contact Characteristics:
Contact Resistance 100 mΩ Switching Voltage 30 Volts DC Max Switching Current 500 mA Max Power 250 mW Max
Wire Connections:
Red 5 Volts DC Black - Ground Green Relay Contact White Relay Contact
2
AQUAVAR SOLO AND BALANCED FLOW
AQUAVAR SOLO AND BALANCED FLOW
Connections for Moisture Sensor (Part Number 9K585) for Balanced Flow, Aquavar SOLO and 3AB2, 5AB2; ABII Controllers
Connect Red wire from Moisture Sensor to transducer terminal marked "R" on controller.
Connect Black wire from Moisture Sensor to transducer terminal marked "B" on controller.
S-DRIVE AND AQUAVAR SPD
S-DRIVE AND AQUAVAR SPD
Connect White and Green wires
from Moisture
Sensor to the RUN/STOP INPUT marked "JUMPER TO RUN" on con­troller.
Connect White and Green wires from Moisture Sensor to the termi­nals 1 and 2 on controller.
Connect Red wire from Mois­ture Sensor to the terminal number 8 on controller.
Connect Black wire
from Moisture Sensor to
the terminal
number 9 on
controller.
3
AQUAVAR ABII OR AQUABOOST II
AQUAVAR ABII OR AQUABOOST II
Connect Black wire
from Moisture Sensor
to terminal marked "Com. (Blk)" on controller.
Connect White
wire from Moisture
Sensor to the White wire of the pressure transducer cable with
a wire nut
Connect Red wire from
Moisture Sensor to
terminal marked "+5V (Red)" on controller.
Connect Green wire
from Moisture Sensor
to terminal marked "Input (Wht)" on controller.
Xylem, Inc. 2881 East Bayard Street Ext., Suite A Seneca Falls, NY 13148
Phone: (866) 325-4210 Fax: (888) 322-5877
www.xyleminc.com/brands/centripro
CentriPro is a trademark of Xylem Inc. or one of its subsidiaries. © 2012 Xylem, Inc. IM234 Rev 1 July 2012