Whirlpool AGB 359/WP, AGB 360/WP, AGB 362/WP, AGB 363/WP, AGB 351/WP INSTRUCTION FOR USE

...
063_03
Instructions for installation, use and maintenance
03/2006
GAS KITCHENS
AGB 350/WP • AGB 352/WP AGB 353/WP AGB 351/WP AGB 354/WP AGB 358/WP • AGB 359/WP AGB 360/WP • AGB 361/WP AGB 362/WP • AGB 363/WP
CHARACTERISTICS
063_03 - GAS KITCHENS
2 · 22
03/2006
Supplied by:
Date:
Customer Service:
FAX
e-mail
INDEX
063_03 - GAS KITCHENS
3 · 22
03/2006
1 Diagram 4
2 Features of the appliances 7
3 Technical data 7-8
4 Installation instructions 9
4.1 Safety rules 9
4.2 Structure, framework and safety devices of the appliances 9
4.2.1 Cooking zone 9
4.2.2 Oven 9 Gas version GN 2/1 and MAXI 9 Gas version GN 1/1 ventilated 9 Electric version GN 2/1 9 Electric version GN 1/1 ventilated 9
4.2.3 Neutral cabinet 9
4.3 Assembly 9
4.3.1 Installation premises 9
4.3.2 Statutory regulations and technical requirements 10
4.3.3 Installation 10
4.3.4 Installation operations 10
4.3.5 Gas connection 10
4.3.6 Smoke extraction 10
4.3.7 Electrical connection 10
4.3.8 Equipotential 10
5 Operation preparation 10
5.1 Preparation and Start-up 10
5.1.1 Start-up 10
5.1.2 Check of power 10
5.1.3 Checking the input pressure 11
5.1.4 Power check with volumetric method 11
5.1.5 Power check for operation with liquid gas 11
5.1.6 Check of pilot flame 11
5.1.7 Checking the primary air 11
5.1.8 Operation Control 13
5.1.9 Operator training 13
5.1.10 Conversion and adjustment 13
5.1.11 Replacement of burner nozzles 13
5.1.12 Setting reduced capacity power 13
5.1.13 Replacement of pilot nozzle (open flames) 13
5.1.14 Replacement of pilot nozzle (gas oven GN 2/1) 13
5.1.15 Replacement of pilot nozzle (gas oven MAXI) 13
5.1.16 Replacement of nozzle of gas ovens GN 1/1 and MAXI 13
5.1.17 Replacement of burner nozzle (gas oven) 13
5.2 Maintenance 13
5.3 Replacing parts 14
5.3.1 Gas valve (open flames) 14
5.3.2 Thermocouple (open flames) 14
5.3.3 Plug (gas oven) 14
5.3.4 Gas valve (gas oven) 14
5.3.5 Thermocouple (gas oven) 14
5.3.6 Main burner (gas oven) 14
5.3.7 Heating elements (electric oven GN 1/1) 14
5.3.8 Heating elements (electric oven GN 2/1) 14
5.3.9 Fan for electric and gas ovens GN 1/1 14
6 Instructions for use 14
6.1 Safety, cleaning and repair rules 14
6.2 Start-up 15
6.2.1 Lighting and disconnecting open flame burner 15
6.3 Lighting and shutting down a gas oven 15
6.3.1 Lighting the pilot (gas oven GN 1/1) 15
6.3.2 Lighting the pilot (gas oven GN 2/1 and MAXI) 15
6.3.3 Lighting the main burner and temperature adjustment
(gas ovens GN 2/1 and MAXI) 16
Shutdown 16
6.3.4 Lighting the main burner and temperature adjustment
in gas oven GN 1/1 16
Shutdown 16
6.4 Lighting and shutdown of electric oven GN 1/1 16
6.5 Lighting and shutdown of electric oven GN 2/1 16
6.6 Turning the appliance off in case of breakdown 16
6.6.1 What to do in case of failure or prolonged period of
disuse 17
6.7 Appliance care and frequency of maintenance 17
6.8 Recommendations for handling stainless steel industrial
kitchens 17
6.8.1 Useful information on stainless steel 17
6.8.2 Warnings and advice for maintenance of stainless steel
appliances 17
6.8.3 WEEE Directive 18
7 Appendix: Electrical diagrams 19-21
1 - DIAGRAM
063_03 - GAS KITCHENS
4 · 22
03/2006
21
53
680
680
220
220
800
AGB 350/WP AGB 351/WP AGB 352/WP
694
AGB 350/WP AGB 351/WP
9.5 kW
9.5
kW
9.5
kW
4.0 kW
295
295
350
350
255
255
3/4"
21
53
590
590
310
310
3/4"
3/4"
970
52
680
220
AGB 350/WP AGB 351/WP AGB 352/WP
100
706
AGB 352/WP
9.5 kW
9.5
kW
3/4"
9.5 kW
9.5
kW
150
142
295
350
255
300900
900
150
590
3/4"
310
200200 400
200 400
200
4.0 kW Ø 100 mm
9.5 kW Ø 125 mm
1 - DIAGRAM
063_03 - GAS KITCHENS
5 · 22
03/2006
AGB 359/WP
53
53
400
294
4.0 kW Ø 100 mm
9.5 kW Ø 125 mm
AGB 360/WP
AGB 361/WP
800
694
140
AGB 358/WPAGB 358/WP
295
9.5 kW
53
590
350
AGB 359/WP
4.0
kW
310
255
200 200
900
340
53
55
35
AGB 360/WP
AGB 361/WP
140
9.5 kW
9.5
kW
200 200
295
350
255
270
590
310
AGB 360/WP
900
9.5 kW
9.5 kW
200 400
9.5 kW
4.0 kW
140
200
295
350
255
AGB 361/WP
900
kW
200 400
9.5 kW
9.5
140
295
9.5 kW
350
9.5
kW
255
200
1 - DIAGRAM
063_03 - GAS KITCHENS
6 · 22
03/2006
AGB 353/WP • AGB 354/WP
21 21
AGB 353/WP • AGB 354/WP
9.5
680
kW
9.5
kW
220
1200
9.5
kW
4.0 kW
4.0 kW
9.5
kW
3/4"
296
350
255
AGB 353/WP • AGB 354/WP
300900
706
100
3/4"
900
150
150
142
970
5353 1094
52
4.0 kW Ø 100 mm
9.5 kW Ø 125 mm
590
3/4"
310
900
200 200400400
AGB 362-363/WP
AGB 362/WP
9.5 kW
9.5
kW
1200
9.5 kW
4.0 kW
4.0 kW
9.5
kW
140
296
350
255
AGB 362-363/WP
900
340
55
5353 1094
AGB 363/WP
9.5 kW
900
9.5
kW
35
140
9.5 kW
9.5
kW
9.5 kW
9.5
kW
270
296
350
255
200 200400400
200 200400400
2 - CHARACTERISTICS OF THE APPLIANCES
3 - TECHNICAL DATA
063_03 - GAS KITCHENS
7 · 22
03/2006
These appliances are used for professional purposes. Installation, repair and use must be carried out by expert personnel.
These instructions for installation are for our gas kitchens set up for the category in the table on page 8.
The data plate is located on the front part of the appliance (on the control panel).
Model
AGB 358-359/WP
AGB 360-361/WP
AGB 362-363/WP
AGB 350-352/WP
AGB 351/WP
AGB 353/WP
AGB 354/WP
Description
2 burners, embossed
4 burners, embossed
6 burners, embossed
4 burners with 1 gas oven GN 2/1
4 burners with 1 electric oven GN 2/1
6 burners with 1 gas oven GN 2/1 and with cabinet
6 burners with 1 gas oven MAXI
Dimensions in mm. (LxDxH)
400 x 900 x 270/340
800 x 900 x 270/340
1200 x 900 x 270/340
800 x 900 x 900/970
800 x 900 x 900/970
1200 x 900 x 900/970
1200 x 900 x 900/970
Nr.
51BQ2899
51BQ2899
51BQ2899
51BQ2899
51BQ2899
51BQ2899
51BQ2899
0051
TIPO/TYPE
CAT/KAT GAS/GAZ G30 G31 G20 G25
II2H3B/P P mbar 30 30 20 ­II2H3+ P mbar 30 37 20 ­II2H3+ P mbar 28 37 20 ­II2L3B/P P mbar 30 30 - 25 II2ELL3B/P P mbar 50 50 20 20 II2E+3+ P mbar 28 37 20 25 II2H3B/P P mbar 50 50 20 ­I2E P mbar - - 20 ­II2H3B/P P mbar 30 30 - ­II2H3+ P mbar 28 37 20 ­I3B/P P mbar 30 30 - ­I3+ P mbar 28 37 - -
SE FI DK CZ SK SI
IT CH PT
ES IE GB GR
NL
DE
FR BE
AT CH
LU
EE LV LT
EE LV LT
NO MT CY IS HU
CY
MOD.
MOD.
ART.
N.
N.
Qn kW
m3/h
MADE IN ITALY
Predisposto a gas: - Gas preset: - Prevu pour gaz:
Eingestelt für Gas: - Preparado para gas: - Geschuckt voor:
V AC kW Hz
THE APPLIANCE MUST BE CONNECTED IN COMPLIANCE WITH CURRENT REGULATIONS AND INSTALLED IN A WELL-VENTILATED ROOM. READ THE INSTRUCTION MANUAL BEFORE INSTALLING AND USING THE APPLIANCE. THE APPLIANCE MUST BE INSTALLED BY QUALIFIED PERSONNEL.
G30/G31 28/37 mbar
G20 20 mbar
Loading...