Pilz PNOZ X11P Data Sheet

Page 1
E-STOP relays, safety gate monitors
Up to PL e of EN ISO 13849-1
PNOZ X11P
Gertebild
][Bildunterschrift_NOT_Sch.tuer_Licht
Approvals
PNOZ X11P
SÜDDEUTSCHLAND
Zulassungen
Unit features
Gertemerkmale
` Positive-guided relay outputs:
– 7 safety contacts (N/O), instanta-
neous
– 1 auxiliary contact (N/C), instan-
taneous
` 2 semiconductor outputs ` Connection options for:
– E-STOP pushbutton – Safety gate limit switch – Reset button
` LED indicator for:
– Switch status channel 1/2 – Supply voltage – Reset circuit – Input circuits
` Semiconductor outputs signal:
– Switch status channel 1/2 – Supply voltage is present
` Plug-in connection terminals (either
spring-loaded terminal or screw terminal)
` See order reference for unit types
Unit description
Bestimmung/Gertebeschreibung NOT-AUS, Schutz_PNOZ
The safety relay meets the require­ments of EN 60947-5-1, EN 60204-1 and VDE 0113-1 and may be used in applications with
` E-STOP pushbuttons
` Safety gates
Safety features
][Sicherheitseigenscha ften Schaltgerät_allgem einer Teil
The relay meets the following safety requirements:
` The circuit is redundant with built-in
self-monitoring.
` The safety function remains effec-
tive in the case of a component fail­ure.
` The correct opening and closing of
the safety function relays is tested automatically in each on-off cycle.
Sicherheitseigenschaften Zusatz - AC/DC-Gerte_PNOZ
` The tranformer is short circuit-
proof. An electronic fuse is used on a DC supply.
Block diagram
Blockschaltbild
A1 A2 13 23 33 43
~
Power
=
B1 B2
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
S11 S12 S21 S22
=
Feed-
back
=
Y1 Y2
S31 S32
InputInput
0 V 24 V
Y30 Y31 Y32 Y35
Input
Reset/
Start
S37S33 S34
Reset/
Start
K1
K2
14 24 34 44
53 63 73 81
54 64 74 82
NSG-D-2-346-2010-08
Page 2
E-STOP relays, safety gate monitors
Up to PL e of EN ISO 13849-1
PNOZ X11P
Function description
][Funktionen_einkanalig
` Single-channel operation: no re-
dundancy in the input circuit, earth faults in the reset and input circuit are detected.
][Funktionen_zweikanalig_mit_quer_ber
` Dual-channel operation with detec-
tion of shorts across contacts: re­dundant input circuit, detects – earth faults in the reset and input
circuit,
Timing diagram
1 2
POWER
Reset/Start
Input
Output safe
Output aux.
Out semi RUN
Out semi CH
t1 t2
t1 t2
– short circuits in the input circuit
and, with a monitored reset, in the reset circuit too,
– shorts between contacts in the
input circuit.
][Funktionen_autoStart
` Automatic start: Unit is active once
the input circuit has been closed.
][Funktionen_manuStart
` Manual reset: Unit is active once
the input circuit is closed and then the reset circuit is closed.
][Funktionen_berStart_allg
` M on it or ed re se t: Un i t i s ac ti ve on c e
][Zeitdiagramm_auto_manu_ueber1_aux_semiRUN_semiCH
ab
t1
t1
t2
– the input circuit is closed and
then the reset circuit is closed and opened again.
– the reset circuit is closed and
then opened again once the in­put circuit is closed.
][Funktionen_Kontaktvervielfachung
` Increase in the number of available
instantaneous safety contacts by connecting contact expansion modules or external contactors.
ab
t2
t1
3
t2
t1
t3
t2
Key
` Power: Supply voltage ` Reset/Start: Reset circuit S33-S34,
S37
` Input: Input circuits S11-S12, S21-
S22, S31-S32
` Output safe: Safety contacts 13-14,
23-24, 33-34, 43-44, 53-54, 63-64, 73-74
Wiring
][Verdrahtung_Si_unverz_1Hi_unverz
Please note:
` Information given in the “Technical
details” must be followed.
` Outputs 13-14, 23-24, 33-34, 43-
44, 53-54, 63-64, 73-74 are safety contacts, output 81-82 is an auxilia­ry contact (e.g. for display).
` To prevent contact welding, a fuse
should be connected before the output contacts (see technical de­tails).
` Calculation of the max. cable runs
in the input circuit:
l
max
` Output aux: Auxiliary contacts 81-
82
` Out semi RUN: Semiconductor out-
put supply voltage Y35
` Out semi CH: Semiconductor out-
put switch status Y32
` c: Automatic reset ` d: Manual reset ` e: Monitored reset
R
lmax
=
I
max
Rl / km
R
= max. overall cable resist-
lmax
ance (see technical details)
/km = cable resistance/km
R
l
` Use copper wire that can withstand
60/75 °C.
` Sufficient fuse protection must be
provided on all output contacts with capacitive and inductive loads.
` a: Input circuit closes before reset
circuit
` b: Reset circuit closes before input
circuit
: Switch-on delay
` t
1
: Delay-on de-energisation
` t
2
: Recovery time
` t
3
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-346-2010-08Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
-2
Page 3
E-STOP relays, safety gate monitors
Up to PL e of EN ISO 13849-1
PNOZ X11P
Preparing for operation
Betriebsbereitschaft her stellen
` Supply voltage
Supply voltage AC DC
A1
A2
B2 PE
L1
N
` Input circuit
Input circuit Single-channel Dual-channel E-STOP
without detection of shorts across con­tacts
E-STOP with detection of shorts across contacts
S21 S22
S12 S11 S32
S31
S1
S11 S12
B1
B2
S22 S32 S31 S21
L+
L-
S1
Safety gate without detection of shorts across con­tacts
Safety gate with detection of shorts across contacts
S21 S22
S12 S11 S32
S31
S1
S11 S12
S22 S21 S32
S31
S1
S2
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-346-2010-08
Page 4
E-STOP relays, safety gate monitors
Up to PL e of EN ISO 13849-1
PNOZ X11P
` Reset circuit
Reset circuit E-STOP wiring (single-channel)
Safety gate (single-channel)
Automatic reset
S33
S34
Manual reset
S33
S34
Monitored reset
S33 S34
S37
S3
S3
E-STOP wiring (dual-channel) Safety gate (dual-channel)
` Feedback circuit
Feedback circuit Automatic reset Monitored reset Contacts from external contactors
Y1 Y2
13 (23 ... 73) 14 (24 ... 74)
K5
K6
K5
K6
L1 N
13 (23 ... 73) 14 (24 ... 74)
S33
S34
S33 S34
S37
Y1 Y2
S33
S34
K5
K6
K5
K6
S3
S3
L1 N
` Semiconductor output
` Key
S1/S2 E-STOP/safety gate switch
S3 Reset button
Switch operated
Gate open
Gate closed
Y31 Y32 Y35 Y30
24 V DC SPS Input SPS Input 0 V
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-346-2010-08Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
-4
Page 5
E-STOP relays, safety gate monitors
Up to PL e of EN ISO 13849-1
PNOZ X11P
Terminal configuration
Klemmenbelegung
Installation
Montage_PNOZ_X
` The safety relay should be installed
in a control cabinet with a protec­tion type of at least IP54.
` Use the notch on the rear of the unit
to attach it to a DIN rail.
` Ensure the unit is mounted securely
on a vertical DIN rail (35 mm) by us­ing a fixing element (e.g. retaining bracket or an end angle).
Dimensions
Abmessungen
* with spring-loaded terminals
94 (3.70")
* 101 (3.98")
121 (4.76")
90
(3.54")
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-346-2010-08
Page 6
E-STOP relays, safety gate monitors
Up to PL e of EN ISO 13849-1
PNOZ X11P
Notice
][WICHTIG_PDB_al t
This data sheet is only intended for use during configuration. For installation and operation, please refer to the op­erating instructions supplied with the
Service life graph
10
AC15: 230 V
unit.
DC13: 24 V
1
D Nennbetriebstrom (A)
GB Nominal operating current (A)
F Courant coupé (A)
][Technische Daten PNOZ
Technical details
Electrical data
Supply voltage Supply voltage U Supply voltage U
AC 24 V, 110 - 120 V, 230 - 240 V
B
DC 24 V
B
Voltage tolerance -15 %/+10 % Power consumption at U Power consumption at U
AC 9.0 VA
B
DC 3.5 W
B
Frequency range AC 50 - 60 Hz Residual ripple DC 160 % Voltage and current at Input circuit DC: 24.0 V 50.0 mA Reset circuit DC: 24.0 V 70.0 mA Feedback loop DC: 24.0 V 70.0 mA Number of output contacts Safety contacts (S) instantaneous: 7 Auxiliary contacts (N/C): 1 Utilisation category in accordance with EN 60947-4-1 Safety contacts: AC1 at 240 V I
Safety contacts: DC1 at 24 V I
Auxiliary contacts: AC1 at 240 V I
Auxiliary contacts: DC1 at 24 V I
Utilisation category in accordance with EN 60947-5-1 Safety contacts: AC15 at 230 V I Safety contacts: DC13 at 24 V (6 cycles/min) I Auxiliary contacts: AC15 at 230 V I Auxiliary contacts: DC13 at 24 V (6 cycles/min) I Contact material AgSnO2 + 0.2 µm Au
0.1
E Corriente nominal de servicio (A)
I Corrente di esercizio nominale (A)
NL Nominale bedrijfsstroom (A)
10 100 1000 10000
D Schaltspielzahl x 10 GB Cycles x 10 F Nombre de manuvres x 10
: 0.01 A , I
min
P
: 2000 VA
max
: 0.01 A , I
min
P
: 200 W
max
: 0.01 A , I
min
: 2000 VA
P
max
: 0.01 A , I
min
P
: 200 W
max
: 5.0 A
max
: 7.0 A
max
: 5.0 A
max
: 7.0 A
max
3
3
: 8.0 A
max
max
max
max
Lebensdauerkurve
: 8.0 A
: 8.0 A
: 8.0 A
DC1: 24 V
AC1: 230 V
E Número de ciclos x 10 I Numero dei cicli di commutazione x 10
3
NL Aantal schakelingen x 10
3
3
3
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-346-2010-08Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
-6
Page 7
E-STOP relays, safety gate monitors
Up to PL e of EN ISO 13849-1
PNOZ X11P
Electrical data
External contact fuse protection (IK = 1 kA) to EN 60947-5-1 Blow-out fuse, quick Safety contacts: 10 A Auxiliary contacts: 10 A Blow-out fuse, slow Safety contacts: 6 A Auxiliary contacts: 6 A Circuit breaker 24 VAC/DC, characteristic B/C Safety contacts: 6 A Auxiliary contacts: 6 A Semiconductor outputs (short circuit proof) 24.0 V DC, 20 mA External supply voltage 24.0 V DC Voltage tolerance -20 %/+20 % Max. overall cable resistance R input circuits, reset circuits single-channel at U single-channel at U dual-channel with detect. of shorts across contacts at U dual-channel with detect. of shorts across contacts at U Min. input resistance in the starting torque 43 Ohm
Safety-related characteristic data
PL in accordance with EN ISO 13849-1 PL e (Cat. 4) Category in accordance with EN 954-1 Cat. 4 SIL CL in accordance with EN IEC 62061 SIL CL 3 PFH in accordance with EN IEC 62061 2.31E-09 SIL in accordance with IEC 61511 SIL 3 PFD in accordance with IEC 61511 2.03E-06
in years 20
t
M
Times
Switch-on delay with automatic reset typ. 450 ms with automatic reset max. 680 ms with automatic reset after power on typ. 450 ms with automatic reset after power on max. 630 ms with manual reset typ. 450 ms with manual reset max. 680 ms on monitored reset with rising edge typ. 390 ms on monitored reset with rising edge max. 550 ms Delay-on de-energisation with E-STOP typ. 17 ms with E-STOP max. 30 ms with power failure typ. 40 ms with power failure max. 60 ms Recovery time at max. switching frequency 1/s after E-STOP 50 ms after power failure 100 ms Min. start pulse duration with a monitored reset with rising edge 30 ms Simultaneity, channel 1 and 2 Supply interruption before de-energisation 20 ms
Environmental data
EMC EN 60947-5-1, EN 61000-6-2 Vibration to EN 60068-2-6 Frequency 10 - 55 Hz Amplitude 0.35 mm Climatic suitability EN 60068-2-78
DC 50 Ohm
B
AC 100 Ohm
B
lmax
DC 15 Ohm
B
AC 20 Ohm
B
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-346-2010-08
Page 8
E-STOP relays, safety gate monitors
Up to PL e of EN ISO 13849-1
PNOZ X11P
Environmental data
Airgap creepage in accordance with EN 60947-1 Pollution degree 2 Overvoltage category III Rated insulation voltage 250 V Rated impulse withstand voltage 4.00 kV Ambient temperature -10 - 55 °C Storage temperature -40 - 85 °C Protection type Mounting (e.g. cabinet) IP54 Housing IP40 Terminals IP20
Mechanical data
Housing material Housing PPO UL 94 V0 Front ABS UL 94 V0 Cross section of external conductors with screw terminals 1 core flexible 0.25 - 2.50 mm² , 24 - 12 AWG No. 777080, 777083, 777086 2 core, same cross section, flexible: with crimp connectors, without insulating sleeve 0.25 - 1.00 mm² , 24 - 16 AWG No. 777080, 777083, 777086 without crimp connectors or with TWIN crimp connectors 0.20 - 1.50 mm² , 24 - 16 AWG No. 777080, 777083, 777086 Torque setting with screw terminals 0.50 Nm No. 777080, 777083, 777086 Cross section of external conductors with spring-loaded termi­nals: Flexible with/without crimp connectors Spring-loaded terminals: Terminal points per connection 2 No. 787080, 787083, 787086 Stripping length 8 mm No. 787080, 787083, 787086 Dimensions Height 101.0 mm No. 787080, 787083, 787086
Width 90.0 mm Depth 121.0 mm Weight 630 g No. 787080, 787083, 787086
Technische Daten_Satz No .
No. stands for order number.
Technische Daten_Satz No rmen
The standards current on 2009-11 apply.
][Dauerstrom_ACDC
0.20 - 1.50 mm² , 24 - 16 AWG No. 787080, 787083, 787086
94.0 mm No. 777080, 777083, 777086
640 g No. 777080, 777083, 777086
Conventional thermal current
Number of contacts I 1 8.00 A 8.00 A 2 8.00 A 8.00 A 3 8.00 A 6.80 A 4 7.20 A 5.90 A 5 6.50 A 5.30 A 6 5.90 A 4.80 A 7 5.50 A 4.50 A
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
(A) at UBDC Ith(A) at UBAC
th
Bestelldaten
NSG-D-2-346-2010-08Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
-8
Page 9
E-STOP relays, safety gate monitors
Up to PL e of EN ISO 13849-1
PNOZ X11P
Order reference
Type Features Terminals Order no.
PNOZ X11P C 24 VAC/DC Spring-loaded terminals 787 080 PNOZ X11P 24 VAC/DC Screw terminals 777 080 PNOZ X11P C 110 - 120 VAC 24 VDC Spring-loaded terminals 787 083 PNOZ X11P 110 - 120 VAC 24 VDC Screw terminals 777 083 PNOZ X11P C 230 - 240 VAC 24 VDC Spring-loaded terminals 787 086 PNOZ X11P 230 - 240 VAC 24 VDC Screw terminals 777 086
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-346-2010-08