This data sheet is only intended for use
during configuration. For installation
and operation, please refer to the operating instructions supplied with the
Service life graph
10
AC15: 230 V
unit.
DC13: 24 V
1
D Nennbetriebstrom (A)
GB Nominal operating current (A)
F Courant coupé (A)
][Technische Daten PNOZ
Technical details
Electrical data
Supply voltage
Supply voltage U
Supply voltage U
AC24 V, 110 - 120 V, 230 - 240 V
B
DC24 V
B
Voltage tolerance-15 %/+10 %
Power consumption at U
Power consumption at U
AC9.0 VA
B
DC3.5 W
B
Frequency range AC50 - 60 Hz
Residual ripple DC160 %
Voltage and current at
Input circuit DC: 24.0 V50.0 mA
Reset circuit DC: 24.0 V70.0 mA
Feedback loop DC: 24.0 V70.0 mA
Number of output contacts
Safety contacts (S) instantaneous:7
Auxiliary contacts (N/C):1
Utilisation category in accordance with EN 60947-4-1
Safety contacts: AC1 at 240 VI
Safety contacts: DC1 at 24 VI
Auxiliary contacts: AC1 at 240 VI
Auxiliary contacts: DC1 at 24 VI
Utilisation category in accordance with EN 60947-5-1
Safety contacts: AC15 at 230 VI
Safety contacts: DC13 at 24 V (6 cycles/min)I
Auxiliary contacts: AC15 at 230 VI
Auxiliary contacts: DC13 at 24 V (6 cycles/min)I
Contact materialAgSnO2 + 0.2 µm Au
0.1
E Corriente nominal de servicio (A)
ICorrente di esercizio nominale (A)
NL Nominale bedrijfsstroom (A)
10100100010000
D Schaltspielzahl x 10
GB Cycles x 10
F Nombre de manuvres x 10
: 0.01 A , I
min
P
: 2000 VA
max
: 0.01 A , I
min
P
: 200 W
max
: 0.01 A , I
min
: 2000 VA
P
max
: 0.01 A , I
min
P
: 200 W
max
: 5.0 A
max
: 7.0 A
max
: 5.0 A
max
: 7.0 A
max
3
3
: 8.0 A
max
max
max
max
Lebensdauerkurve
: 8.0 A
: 8.0 A
: 8.0 A
DC1: 24 V
AC1: 230 V
E Número de ciclos x 10
INumero dei cicli di commutazione x 10
External contact fuse protection (IK = 1 kA) to EN 60947-5-1
Blow-out fuse, quick
Safety contacts:10 A
Auxiliary contacts:10 A
Blow-out fuse, slow
Safety contacts:6 A
Auxiliary contacts:6 A
Circuit breaker 24 VAC/DC, characteristic B/C
Safety contacts:6 A
Auxiliary contacts:6 A
Semiconductor outputs (short circuit proof)24.0 V DC, 20 mA
External supply voltage24.0 V DC
Voltage tolerance-20 %/+20 %
Max. overall cable resistance R
input circuits, reset circuits
single-channel at U
single-channel at U
dual-channel with detect. of shorts across contacts at U
dual-channel with detect. of shorts across contacts at U
Min. input resistance in the starting torque43 Ohm
Safety-related characteristic data
PL in accordance with EN ISO 13849-1PL e (Cat. 4)
Category in accordance with EN 954-1Cat. 4
SIL CL in accordance with EN IEC 62061SIL CL 3
PFH in accordance with EN IEC 620612.31E-09
SIL in accordance with IEC 61511SIL 3
PFD in accordance with IEC 615112.03E-06
in years20
t
M
Times
Switch-on delay
with automatic reset typ.450 ms
with automatic reset max.680 ms
with automatic reset after power on typ.450 ms
with automatic reset after power on max.630 ms
with manual reset typ.450 ms
with manual reset max.680 ms
on monitored reset with rising edge typ.390 ms
on monitored reset with rising edge max.550 ms
Delay-on de-energisation
with E-STOP typ.17 ms
with E-STOP max.30 ms
with power failure typ.40 ms
with power failure max.60 ms
Recovery time at max. switching frequency 1/s
after E-STOP50 ms
after power failure100 ms
Min. start pulse duration with a monitored reset
with rising edge30 ms
Simultaneity, channel 1 and 2∞
Supply interruption before de-energisation 20 ms
Environmental data
EMCEN 60947-5-1, EN 61000-6-2
Vibration to EN 60068-2-6
Frequency10 - 55 Hz
Amplitude0.35 mm
Climatic suitabilityEN 60068-2-78