ER800 THRU ER804
SUPERFAST RECOVERY RECTIFIERS
VOLTAGE - 50 to 400 Volts |
CURRENT - 8.0 Amperes |
FEATURES |
TO-220AC |
•Plastic package has Underwriters Laboratory Flammability Classification 94V-O utilizing Flame Retardant Epoxy Molding Compound
•Exceeds environmental standards of MIL-S-19500/228
•Low power loss, high efficiency
•Low forward voltage, high current capability
•High surge capacity
•Super fast recovery times, high voltage
•Epitaxial chip construction
MECHANICAL DATA
Case: TO-220AC molded plastic
Terminals: Lead, solderable per MIL-STD-202, Method 208
Polarity: As marked
Mounting Position: Any
Weight: 0.08 ounces, 2.24 grams
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 ¢J ambient temperature unless otherwise specified.
Single phase, half wave, 60Hz, Resistive or inductive load.
For capacitive load, derate current by 20%.
|
ER800 |
ER801 |
|
ER801A |
|
ER802 |
ER803 |
|
ER804 |
UNITS |
|
Maximum Recurrent Peak Reverse Voltage |
50 |
100 |
|
150 |
|
200 |
|
300 |
|
400 |
V |
Maximum RMS Voltage |
35 |
70 |
|
105 |
|
140 |
|
210 |
|
320 |
V |
Maximum DC Blocking Voltage |
50 |
100 |
|
150 |
|
200 |
|
300 |
|
400 |
V |
Maximum Average Forward Rectified |
|
|
8.0 |
|
|
|
|
|
A |
||
Current at TC=100 ¢J |
|
|
|
|
|
|
|
|
|
|
|
Peak Forward Surge Current, |
|
|
125 |
|
|
|
|
|
A |
||
8.3ms single half sine-wave superimposed |
|
|
|
|
|
|
|
|
|
|
|
on rated load(JEDEC method) |
|
|
|
|
|
|
|
|
|
|
|
Maximum Forward Voltage at 8.0A per |
|
0.95 |
|
|
|
1.30 |
|
V |
|||
element |
|
|
|
|
|
|
|
|
|
|
|
Maximum DC Reverse Current at Ta=25 ¢J |
|
|
10 |
|
|
|
|
|
£g A |
||
DC Blocking Voltage per element Ta=125 ¢J |
|
|
500 |
|
|
|
|
|
|
||
Typical Junction capacitance (Note 1) |
|
|
62 |
|
|
|
|
|
PF |
||
Maximum Reverse Recovery Time(Note 2) |
|
|
35 |
|
|
|
50 |
|
ns |
||
Typical Junction Resistance(Note 3) R £KJC |
|
|
3.0 |
|
|
|
|
|
¢J /W |
||
Operating and Storage Temperature Range TJ |
|
|
|
-55 to +150 |
|
|
|
¢J |
NOTES:
1.Measured at 1 MHz and applied reverse voltage of 4.0 VDC
2.Reverse Recovery Test Conditions: IF=.5A, IR=1A, Irr=.25A
3.Thermal resistance junction to CASE