PG5400 THRU PG5408
GLASS PASSIVATED JUNCTION PLASTIC RECTIFIER
VOLTAGE - 50 to 1000 Volts CURRENT - 3.0 Amperes
FEATURES
•Plastic package has Underwriters Laboratory
DO-201AD
Flammability Classification 94V-O utilizing Flame Retardant Epoxy Molding Compound
•Glass passivated junction in DO-201AD package
•3.0 ampere operation at TA=55 ¢J with no thermal runaway
•Exceeds environmental standards of MIL-S-19500/228
•Low reverse leakage current
MECHANICAL DATA
Case: Molded plastic
Terminals: Axial leads, solderable per MIL-STD-202,
Method 208
Mounting Position: Any
Weight: 0.04 ounce, 1.1 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 ¢J ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
|
PG5400 |
PG5401 |
PG5402 |
|
PG5404 |
|
PG5406 |
PG5407 |
PG5408 |
UNITS |
Maximum Recurrent Peak Reverse Voltage |
50 |
100 |
200 |
|
400 |
|
600 |
800 |
1000 |
V |
Maximum RMS Voltage |
35 |
70 |
140 |
|
280 |
|
420 |
560 |
700 |
V |
Maximum DC Blocking Voltage |
50 |
100 |
200 |
|
400 |
|
600 |
800 |
1000 |
V |
Maximum Average Forward Rectified |
|
|
|
3.0 |
|
|
|
|
A |
|
Current .375"(9.5mm) lead length |
|
|
|
|
|
|
|
|
|
|
at TA=55 ¢J |
|
|
|
|
|
|
|
|
|
|
Peak Forward Surge Current, 8.3ms single |
|
|
|
150 |
|
|
|
|
A |
|
half sine-wave superimposed |
|
|
|
|
|
|
|
|
|
|
on rated load(JEDEC method) |
|
|
|
|
|
|
|
|
|
|
Maximum Forward Voltage at 3.0A |
|
|
|
1.2 |
|
|
|
|
V |
|
Maximum Reverse Current at Ta=25 ¢J |
|
|
|
5.0 |
|
|
|
|
£g A |
|
At Rated DC Blocking Voltage Ta=100 ¢J |
|
|
|
100 |
|
|
|
|
£g A |
|
Typical Junction capacitance (Note 1) |
|
|
|
30 |
|
|
|
|
PF |
|
Typical Thermal Resistance R £KJA(Note 2) |
|
|
|
20 |
|
|
|
|
¢J /W |
|
Typical Reverse Recovery Time(Note 3) |
|
|
|
2 |
|
|
|
|
£g S |
|
Operating and Storage Temperature Range |
|
|
|
-55 to +150 |
|
|
|
¢J |
||
TA |
|
|
|
|
|
|
|
|
|
|
NOTES:
1.Measured at 1 MHz and applied reverse voltage of 4.0 VDC
2.Thermal resistance from junction to ambient and from junction to lead at 0.375”(9.5mm) lead length P.C.B mounted
3.Reverse Recovery Test Conditions: IF=.5A, IR=1A, Irr=2.5A