ER100 THRU ER106 |
|
|
|
SUPERFAST RECOVERY RECTIFIERS |
|
|
|
VOLTAGE - 50 to 600 Volts CURRENT - 1.0 Ampere |
||
FEATURES |
DO-41 |
||
• |
Superfast recovery times-epitaxial construction |
||
|
|||
• Low forward voltage, high current capability |
|
||
• Exceeds environmental standards of MIL-S-19500/228 |
|
||
• |
Hermetically sealed |
|
|
• |
Low leakage |
|
|
• |
High surge capability |
|
• Plastic package has Underwriters Laboratories Flammability Classification 94V-O utilizing Flame Retardant Epoxy Molding Compound
MECHANICAL DATA
Case: Molded plastic, DO-41
Terminals: Axial leads, solderable to MIL-STD-202,
Method 208
Polarity: Color Band denotes cathode end
Mounting Position: Any
Weight: 0.012 ounce, 0.3 gram
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 ¢J ambient temperature unless otherwise specified. Resistive or inductive load, 60Hz.
|
ER100 |
ER101 |
ER101A |
|
ER102 |
|
ER103 |
ER104 |
ER106 |
UNITS |
Maximum Recurrent Peak Reverse Voltage |
50 |
100 |
150 |
|
200 |
|
300 |
400 |
600 |
V |
Maximum RMS Voltage |
35 |
70 |
105 |
|
140 |
|
210 |
320 |
420 |
V |
Maximum DC Blocking Voltage |
50 |
100 |
150 |
|
200 |
|
300 |
400 |
600 |
V |
Maximum Average Forward |
|
|
|
1.0 |
|
|
|
|
A |
|
Current .375"(9.5mm) lead length |
|
|
|
|
|
|
|
|
|
|
at TA=55 ¢J |
|
|
|
|
|
|
|
|
|
|
Peak Forward Surge Current, IFM (surge): |
|
|
|
30.0 |
|
|
|
|
A |
|
8.3ms single half sine-wave superimposed |
|
|
|
|
|
|
|
|
|
|
on rated load(JEDEC method) |
|
|
|
|
|
|
|
|
|
|
Maximum Forward Voltage at 1.0A DC |
|
.95 |
|
|
|
1.25 |
1.7 |
V |
||
Maximum DC Reverse Current |
|
|
|
5.0 |
|
|
|
|
£g A |
|
at Rated DC Blocking Voltage |
|
|
|
|
|
|
|
|
|
|
Maximum DC Reverse Current at |
|
|
|
150 |
|
|
|
|
£g A |
|
Rated DC Blocking Voltage TA=125 ¢J |
|
|
|
|
|
|
|
|
|
|
Maximum Reverse Recovery Time(Note 1) |
|
|
|
35.0 |
|
|
|
|
ns |
|
Typical Junction capacitance (Note 2) |
|
|
|
17 |
|
|
|
|
PF |
|
Typical Junction Resistance(Note 3) R £KJA |
|
|
|
50 |
|
|
|
|
¢J /W |
|
Operating and Storage Temperature Range TJ |
|
|
|
-55 to +150 |
|
|
|
¢J |
||
NOTES: |
|
|
|
|
|
|
|
|
|
|
1.Reverse Recovery Test Conditions: IF=.5A, IR=1A, Irr=.25A
2.Measured at 1 MHz and applied reverse voltage of 4.0 VDC
3.Thermal resistance from junction to ambient and from junction to lead length 0.375”(9.5mm) P.C.B. mounted