Fully Integrated
36” MasterCool II
All Refrigerator:
K 2901 Vi / K 2911 Vi
All Freezer:
F 2901 Vi / F 2911 Vi
Bottom Mount:
KF 2901 Vi / KF 2911 Vi
French Door:
KF 2981 Vi
Shown: KF 2981 Vi |
8miele.ca |
Please note: This information is subject to change |
Specification Sheets TRS 04252019 |
Fully Integrated
36” MasterCool II
|
SPECIFICATIONS |
|
|
|
|
|
|
|
Overall Unit Dimensions |
353/4” (908 mm) W x 833/4”- 853/16” (2127 - 2164 mm) H x 24” (610 mm) D [Depth does not include door panel] |
|
||||
|
Niche |
|
|
|
|
|
|
|
Minimum Cabinet Niche Opening |
36” (915 mm) W* x 84” - 853/16” (2134 - 2164 mm) H x 243/4” (629 mm) D |
|
||||
|
Interior Volume |
K 29x1 Vi |
|
F 29x1 Vi |
|
KF 29x1 Vi |
|
|
Refrigeration Volume |
** |
|
0 |
|
** |
|
|
Freezer Volume |
0 |
|
** |
|
* |
|
|
Electrical |
K 29x1 Vi |
|
F 29x1 Vi |
|
KF 29x1 Vi |
|
|
Electrical Requirements |
|
|
110V / 120V, 60Hz, 15 Amps |
|
|
|
|
In the case of side-by-side installations, a separate outlet must be used for each appliance. |
|
|||||
|
|
|
|||||
|
Power Cord |
|
|
NEMA 5-15 plug, 5 ft (1.52 m) |
|
|
|
|
|
|
|
|
|
|
|
|
Plumbing |
K 29x1 Vi |
|
F 29x1 Vi |
|
KF 29x1 Vi |
|
|
|
|
|
Connect to a cold water supply only. Do not connect to a low-mineral or |
|
||
|
|
|
|
a reverse osmosis system. Must be connected to a shut-off valve. The |
|
||
|
Water Supply Requirements |
- |
|
water shut-off valve must be accessible after installation. The water pres- |
|
||
|
|
|
|
sure must be between 29 psi (2 bar) and 116 psi (8 bar). If the pressure is |
|
||
|
|
|
|
higher than 120 psi (8.3 bar), a pressure reducing valve must be installed. |
|
||
|
Water Connection Line |
- |
|
Standard 1/4” O.D flexible water line. The maximum outer diameter of the |
|
||
|
|
water pipe (without fittings): 3/8” (10 mm). Water line is not included. |
|
||||
|
|
|
|
|
|||
|
Shipping |
K 29x1 Vi |
|
F 29x1 Vi |
|
KF 29x1 Vi |
|
|
Shipping Weight |
435 lbs (197 kg) |
|
462 lbs (210 kg) |
|
507 lbs (230 kg) |
|
|
Shipping Dimensions |
|
40” (1016 mm) W x 8913/16” (1,294 mm) H x 291/4” (800 mm) D |
|
|
||
|
Support |
|
|
|
|
|
|
|
Call Miele |
|
(800) 565-6435 |
|
|
|
|
|
Miele Website |
|
|
8www.miele.ca |
|
|
|
|
20/20 Link |
|
|
82020technologies.com |
|
|
Please note the following:
•This specification sheet is for a single built-in unit.
•When combining multiple MasterCool units side-by-side, please refer to the Merging Kit specification sheet.
*If design calls for a partition less than 6 5/16” (160 mm) the left unit’s cutout will require an additional 1/8” (3 mm) to the width to allow installation of
the Heating Mat/Merge Kit.
K 2901 Vi (Right Hinged) |
F 2901 Vi (Right Hinged) |
KF 2901 Vi (Right Hinged) |
KF 2981 Vi (French Door) |
K 2911 Vi (Left Hinged) |
F 2911 Vi (Left Hinged) |
KF 2911 Vi (Left Hinged) |
|
Page 2 of 12
Fully Integrated
36” MasterCool II
CUTOUT DIMENSIONS
• Niche depth assumes a 3/4” (19 mm) panel, please adjust according to custom panel thickness
CUTOUT DETAILS
•The electrical connection must not be positioned higher than 9” (228.6 mm) above the floor.
•The 1/4” (6.4 mm) plumbed water connection should
not be positioned higher than 2” (50.8 mm) above the floor.
Notes:
In case of an emergency the electrical outlet must be easily accessible and must not be concealed behind the appliance.
Page 3 of 12
Fully Integrated
36” MasterCool II
POWER SUPPLY AND WATER CONNECTION
(Water Connection For F 29x1 Vi & KF 29x1 Vi Only)
Rear View |
Front View |
Electrical - 5 foot (1.52 m) - 120 Volt - 15 Amp |
Water connection is located in front of unit. |
- NEMA 5-15 molded plug |
1/4” compression fitting is needed. |
Water line - 1/4” flexible water line - not included |
|
Side View
Electrical
Connection
Page 4 of 12