Lexicon LX-5, LX-7 User Manual

User Guide
IMPORTANT SAFETY INSTRUCTIONS
This triangle, which appears on your component,
alerts you to the presence of uninsulated,
dangerous voltage inside the enclosure -
voltage that may be sufficient to
constitute a risk of shock.
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
This triangle, which appears on your component,
alerts you to important operating and
maintenance instructions in this
accompanying literature.
1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with a dry cloth.
8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatuses that produce heat.
9) Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
10) Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
11) Only use attachments/accessories specified by the manufacturer.
12) Use only with a cart, stand, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13) Unplug this apparatus during lightning storms or when unused for long periods of time.
14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15) To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
A Harman International Company
Manufactured under license from Lucasfilm, Ltd. U.S. patent numbers 5,043,970; 5,189,703; and 5,222,059. Foreign patents pending. “Lucasfilm” and “THX” are registered trademarks of Lucasfilm, Ltd.
© 2001 Lexicon, Inc. All rights reserved.
This document should not be construed as a commitment on the part of Lexicon, Inc. The information it contains is subject to change without notice. Lexicon, Inc. assumes no responsibility for errors that may appear within this document.
133792-1
Lexicon, Inc. 3 Oak Park Bedford, MA 01730-1441 USA Tel 781-280-0300 Fax 781-280-0490 www.lexicon.com
Customer Support
Tel 781-280-0300 Fax 781-280-0495 (Sales) Fax 781-280-0499 (Service)
Lexicon Part No. 070-14876 | Rev 0 | 09/01
Introduction
ES FR
IT
DE
PT
US
Lexicon
Introduction
Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . .viii
Desempacotando e Inspeção . . . . . . . . . . . . . . . . . . .viii
Auspackend und Inspektion . . . . . . . . . . . . . . . . . . . .viii
Desempaquetando e Inspección . . . . . . . . . . . . . . . . .viii
Déballer et Inspectión . . . . . . . . . . . . . . . . . . . . . . . .viii
Spacchettando ed Ispezione . . . . . . . . . . . . . . . . . . . .viii
Section 1: Getting Started
About the LX Power Amplifiers . . . . . . . . . . . . . . . . . . . . . . . 1-2
Highlights
Using the Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
User Guide Symbols
Product Registration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Location Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
Section 2: Basic Operation
Front Panel Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
Rear Panel Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Cooling System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Protection Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-8
Thermal Protection • DC Protection
Section 3: Troubleshooting and Maintenance
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -3-3
Appendix
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
Declaration of Conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
Index
ii
LX Power Amplifiers
US
PT
DE
ES
FR
IT
Introduction
UNPACKING AND INSPECTION
After unpacking the unit, save all packing materials in case the unit ever needs to be shipped. Thoroughly inspect the modules and packing materials for signs of damage. Report any damage to the carrier at once; report equipment malfunction to the dealer.
DESEMPACOTANDO E INSPEÇÃO
Depois de desempacotar a unidade, economiza todos os materiais de embalagem no caso de você já precisa transportar a unidade. Completamente inspecione os módulos e empacotando materiais para sinais de dano. Informe qualquer dano imediatamente ao portador; mau funcionamento de equipamento de relatório para seu negociante.
AUSPACKEND UND INSPEKTION
Nach dem Auspacken der Einheit, außer allen Verpackung Materialien, falls Sie die Einheit je verschicken müssen. Inspizieren Sie die Bauelemente und packende Materialien gründlich für Zeichen von Schaden. Berichten Sie sofort irgendeinen Schaden zum Boten; Bericht-Ausrüstung-Funktionsstörung zu Ihrem Händler.
DESEMPAQUETANDO E INSPECCIÓN
Después de desempaquetar la unidad, ahorra todos los materiales del embalaje en caso de que usted alguna vez necesita enviar la unidad. Completamente inspeccione los módulos y condensando los materiales para las señales de daño. Informe cualquier daño en seguida al portador; el funcionamiento defectuoso de equipo de informe a su distribuidor.
DÉBALLER ET INSPECTIÓN
Après avoir déballé l'unité, sauve toutes les matières de l'emballage au cas où vous avez besoin jamais de transporter l'unité. Entièrement inspectez les modules et emballer des matières pour signes de dégât. Rapportez tout dégât au porteur à la fois; fonctionnement défectueux du matériel du rapport à votre revendeur.
SPACCHETTANDO ED ISPEZIONE
Dopo avere spacchettato l'unità, mai salvi tutti i materiali di imballaggio in caso che Lei ha bisogno di inviare l'unità. Completamente ispezioni i moduli e comprimendo materiali per segnali di danno. Subito riporti alcun danno al corriere; malfunzionamento di attrezzatura di rapporto al Suo rivenditore.
iii
1
Getting Started
About the LX Power Amplifiers .....................................................1-2
Highlights
Using the Documentation.............................................................1-3
User Guide Symbols
Product Registration......................................................................1-3
Location Considerations................................................................1-3
Getting Started
Lexicon
ABOUT THE LX POWER AMPLIFIERS
Thank you for purchasing an LX Power Amplifier. The LX amplifiers are designed to meet the highest standards of performance and sound quality. In addition, THX Ultra Certification ensures that the amplifiers meet the highest standards set forth by Lucasfilm’s Home THX division.
The LX amplifiers include many unique technologies that allow them to deliver exceptional performance, even under extreme operating conditions. The amplifiers feature Junction Temperature Simulation (JTS) advanced thermal protection. An internal JTS computer predicts internal temperatures and protects output transistors from overheating, allowing the amplifiers to achieve maximum performance with a minimum number of output transistors. This design enhances performance and reliability.
In addition to JTS, the LX amplifiers feature thermal protection for each channel and the main power transformer. The amplifiers also provide DC protection for each channel, preventing DC and frequencies below 10Hz from reaching the speakers.
The LX amplifiers offer high-power output that can be configured for almost any system. The LX-7 has seven 200W channels, and the LX-5 has five 200W channels. Both amplifiers can be bridged to provide as many as two 400W channels, in addition to the remaining 200W channels. Heavy-duty speaker outputs and selectable balanced or unbalanced audio inputs are also available.
A rear panel TRIGGER INPUT allows the LX amplifiers to be powered on and off by external devices. A GROUND LIFT switch helps eliminate audible hum caused by multiple grounding paths in the system.
Built to Lexicon standards, the LX Power Amplifiers establish a new benchmark for home theater amplifiers. An unbeatable combination of sound quality, power, flexibility, and reliability makes these amplifiers at home in virtually any system.
HIGHLIGHTS
200W per channel
Four custom designed, hand-graded output transistors per channel
Bridgeable architecture for higher power output (400W at 8Ω)
Oversized toroidal power transformer with extraordinarily low DC resistance and thermal protection
High-power supply voltage (160V) for extra headroom at the outputs
THX Ultra Certification
Junction Temperature Simulation (JTS) to provide maximum performance from output transistors
Thermal protection against overheating
Speaker protection against DC and frequencies below 10Hz
Protection against short circuits, device failures, miswiring, and internal faults
Stable with mismatched, reactive, or unusual loads
Quiet, microprocessor controlled, forced-air cooling to minimize chassis size
Compatible with 2speaker impedances (INDIVIDUAL Mode)
Trigger input for power control from an external device
RCA, XLR, and 1/4-inch Tip/Ring/Sleeve inputs
Ground lift switch
Heavy-duty gold plated outputs
Multi-color channel status LEDs
Rack-mount option available
1-2
LX Power Amplifiers
Getting Started
USING THE DOCUMENTATION
Refer to this documentation for assistance with installation and operation of the amplifier. Read all instructions and safety precautions.
USER GUIDE SYMBOLS
The following symbols appear throughout this user guide:
WARNING
CAUTION
Calls attention to a procedure, practice, condition or the like that, if not correctly performed or adhered to, could result in injury or death.
Calls attention to a procedure, practice, condition or the like that, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the product.
Note: Calls attention to information that is essential
to highlight.
LOCATION CONSIDERATIONS
The LX Power Amplifiers require care during installation to ensure optimal performance. The amplifiers should be installed in an equipment rack using an optional rack-mount kit available from Lexicon dealers or www.lexicon.com. Leave at least 2 inches of open space around the top, sides, and rear of the amplifier for proper ventilation.
CAUTION
Be careful when moving the LX Power Amplifers, which are quite heavy.
Do not obstruct the ventilation holes in the chassis.
PRODUCT REGISTRATION
This LX Power Amplifier can be registered by returning the Product Registration card attached to the back cover of this user guide or by visiting www.lexicon.com. Please also retain the bill of sale, which represents proof of purchase and warranty.
1-3
Loading...
+ 18 hidden pages