KitchenAid KICV167RMT, KICV167RSS Dimension Guide

0 (0)
PRODUCT MODEL NUMBERS OVERALL DIMENSIONS
CABINET OPENING DIMENSIONS
VENTING REQUIREMENTS
KICV167R
Electrical: 120-volt, 60-Hz, AC-only, 15-amp. electrical supply. Use copper wire only. A time­delay fuse or circuit breaker and separate circuit is recommended.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. 9763382
09-27-06
®
Horizontal wall venting
Vertical roof venting
elbow
wall cap
Maximum length = 35 ft. (10.7 m)
1 — 90° elbow = 5 ft. (1.5 m) 8 ft. (2.4 m) straight = 8 ft. (2.4 m) 1 — wall cap = 0 ft. (0 m)
system length =13 ft. (3.9 m)
6 ft. (1.8 m)
2 ft.
(0.6 m)
6"
(15.2 cm) v
ent system
To calculate the length of the system you need, add the equivalent feet for each vent piece used in the system.
Note: Flexible vent is Not recommended.
18" (45.7 cm) min. clearance upper cabinet to countertop
X
36" (91.4 cm)
countertop height
30" (76.2 cm) or 36" (91.4 cm)
cabinet opening width
(if installed between cabinets)
See
Note
Vent piece 6" (15.2 cm) round
45° elbow 2.5 feet
(0.8 m)
90° elbow 5.0 feet
(1.5 m)
roof cap
wall cap
Non-vented (recirculating) Kit Nos. 4396911 and 4396912 chimney dimensions
Note:
The hood chimneys are adjustable
and designed to meet varying ceiling or soffit heights depending on the distance “X” between the bottom of the hood and the cooking surface. For higher ceilings, a 40” (10.2 cm) chimney extension Kit No. 4396913 or Kit No. 4396914 is available. The chimney extension replaces the upper chimney shipped with the hood. The chimney extension can be cut as needed. For shorter ceilings or soffits, the upper chimney can be cut.
Important:
Minimum distance “X”: 24” (61.0 cm) Suggested maximum distance “X”:
30” (76.2 cm)
As shown in charts below: For vented installations, the chimneys can be adjusted for ceilings between 7’ 7-1/8” (2.31 m) and 9’ 1-3/4” (2.79 m).
For non-vented (recirculating) installations, the chimneys can be adjusted for ceilings between 8’ 3-3/8” (2.52 m) and 9’ 5-1/4” (2.88 m).
Important:
As hood height (distance X)
increases, hood's venting effectiveness decreases.
23
⁵⁄₈
"
(60.0 cm)
13
³⁄₄
"
(34.9 cm)
12
¹⁄₁₆
"
(30.6 cm)
4
³⁄₄
"
(12.1 cm)
35
³⁄₈
" (89.9 cm)
27
¹⁄₂
"
(69.9 cm)
26
³⁄₈
" (65.1 cm)
min.
39" (99.1cm)
max.
23
⁵⁄₈
"
(60.0 cm)
12
¹⁄₂
"
(31.8 cm)
3
¹⁄₂
"
(8.9 cm)
5"
(12.7 cm)
13
³⁄₄
"
(34.9 cm)
12
¹⁄₁₆
"
(30.6 cm)
32" (81.3 cm)
min.
39" (99.1 cm)
max.
overall
chimney
height
lower
chimney
height
upper
chimney
lower
chimney
height
overall
chimney
height
Loading...