KEYENCE SJ User Manual

CAUTION
Earth Earth
Brown wire and brown/white wire
Brown wire and brown/white wire
Static eliminator
Static eliminator
Blue wire and blue/white wire
Blue wire and blue/ white wire
Power supply device
Power supply device
Shielded wire (thick, black wire)
SJ-CUSJ-CU
Shielded wire (thick, black wire)
96M0946
Connecting the SJ Series
When using the power-supply, 10-pin I/O cable (SJ-CU) to connect to a power supply device, ground the shielded wire (the thick, black wire). Failure to do so may lead to damage to the power supply and to the static eliminator. In addition, you may not be able to perform correct static elimination.
[1] When the power supply device
is not grounded, ground the shielded wire.
[2] When the shielded wire of the
I/O cable is wired to the earth terminal of the power supply device, ground the system correctly from the earth terminal.
<CAUTION> Each time that you perform wiring, do so correctly by following the
instructions in the static eliminator's user's manual.
• Before you start the power supply, you have to disconnect only the pink wire (the static elimination stoppage input signal wire) from the bundled cable that contains this wire and the two blue wires (the blue wire and the blue/white wire). When the product is shipped from the factory, it is put into a state in which static elimination is stopped to ensure safety.
• Be sure to wire the brown wire together with the brown/white wire and the blue wire together with the blue/white wire.