AV-32WFX1EUG
AV-32WFX1EUS
AV-28WFX1EUG
AV-28WFX1EUS
SERVICE MANUAL
COLOUR TELEVISION
AV-32WFX1EUG / AV-28WFX1EUG AV-32WFX1EUS / AV-28WFX1EUS
BASIC CHASSIS
MD
Supplementary
Since some details of the AV-32WFX1EUG / AV-32WFX1EUS / AV-28WFX1EUG / AV-28WFX1EUS service manual (No.51700 Mar. 2000) were changed, we are informing you of these changes and of the new descriptions.
To improve CRT performance, CRT manufacturer has changed location of VM coil wire connector on the CRT neck.
When changing CRT from old to new type, it is necessary to add extension cable CHHB03-100R-SA, between CRT SKT PCB and new VM coil connector.
When ordering replacement CRT, Please order CHHB03-100R-SA at same time.
Old type: Has a short VM wire, coming from the CRT VM PCB/Coil Assy for connecting to CRT PCB VM coil wire.
New type: VM coil wire is connected directly into the right hand side of CRT neck.
CRT SOCKET PWB ASSY |
VM COIL WIRE |
|
[Fig.1]
CRT SOCKET PWB ASSY |
|
|
|
|
|
||
VM COIL WIRE |
|||
|
|||
|
|||
[Fig.2] |
COPYRIGHT © 2001 VICTOR COMPANY OF JAPAN, LTD. |
No.51700E |
|