HP HLMP-3350, HLMP-3568, HLMP-3351, HLMP-3365, HLMP-3366 Datasheet

...
0 (0)
T-13/4 (5 mm) Low Profile LED Lamps
Technical Data
H
HLMP-335X Series HLMP-336X Series HLMP-345X Series HLMP-346X Series HLMP-355X Series HLMP-356X Series

Features

• Low Profile: 5.8 mm (0.23 in.) Nominal
• T-13/4 Diameter Package
• Diffused and Non-diffused Types
• General Purpose Leads
• IC Compatible/Low Current Requirements
• Reliable and Rugged

Description

The HLMP-335X/-336X Series are Gallium Arsenide Phosphide on Gallium Phosphide High Efficiency Red Light Emitting Diodes.
The HLMP-345X/-346X Series are Gallium Arsenide Phosphide on Gallium Phosphide Yellow Light Emitting Diodes.
The HLMP-355X/-356X Series are Gallium Phosphide Green Light Emitting Diodes.
The Low Profile T-13/4 package provides space savings and is excellent for backlighting applications.

Package Dimensions

5.34 (0.210)
4.83 (0.190)
5964-9295E
1-101

Selection Guide

Part Minimum
Number Intensity @
HLMP- Application 10 mA (mcd) Lens
3350 Indicator – General Purpose 2.1 Tinted Diffused Wide Angle 3351 Indicator – High Brightness 5.4 HER 3365 General Purpose Point Source 8.6 Tinted Non-diffused Narrow Angle 3366 Indicator – High Brightness 13.8 HER 3450 Indicator – General Purpose 2.2 Tinted Diffused Wide Angle 3451 Indicator – High Brightness 5.7 Yellow 3465 General Purpose Point Source 5.7 Tinted Non-diffused Narrow Angle 3466 Indicator – High Brightness 9.2 Yellow 3553 Indicator – General Purpose 1.6 Tinted Diffused Wide Angle 3554 Indicator – High Brightness 6.7 Green 3567 General Purpose Point Source 4.2 Tinted Non-diffused Narrow Angle 3568 Indicator – High Brightness 10.6 Green
1-102
High Efficiency Red HLMP-335X/-336X Series
Electrical Specifications at T
Symbol Description HLMP- Min. Typ. Max. Units Conditions
I
V
2θ1/2 Including Angle Between Half 3350 50 Deg. Note 1 (Figure 11)
λ
PEAK
λ
∆λ
τ
C Capacitance 11 pF VF = 0; f = 1 MHz
Rθ
J-PIN
V
V
η
Notes:
1. θ1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity.
2. Dominant wavelength, λd, is derived from the CIE chromaticity diagram and represents the single wavelength which defines the color
of the device.
3. Radiant Intensity, Ie, in watts/steradian may be found from the equation Ie = Iv/ηv, where Iv is the luminous intensity in candelas and
ηv is the luminous efficacy in lumens/watt.
Axial Luminous Intensity 3350 2.1 3.5 mcd IF = 10 mA
Luminous Intensity Points 3351 50
Peak Wavelength 635 nm Measurement at
Dominant Wavelength 626 nm Note 2
d
Spectral Line Halfwidth 40 nm
1/2
Speed of Response 90 ns
s
Thermal Resistance 260 °C/W Junction to
Forward Voltage 1.9 2.4 V IF = 10 mA
F
Reverse Breakdown Voltage 5.0 V IR = 100 µA
R
Luminous Efficacy 145 lm/W Note 3
V
= 25°C
A
Device Test
3351 5.4 7.0 (Figure 8) 3365 8.6 10.0 3366 13.8 18.0
3365 45 3366 45
Peak (Figure 1)
Cathode Lead
(Figure 7)
Figure 7. Forward Current vs. Forward Voltage.
Figure 8. Relative Luminous Intensity vs. Forward Current.
Figure 9. Relative Efficiency (Luminous Intensity per Unit Current) vs. Peak Current.
1-103