Haier HC60D1VAE, HC48D1VAE, HC42D2VAE, HC36D2VAE, HC30D2VAE Owner’s Manual

...
0 (0)

0

0150505380 D

HBrand symbol-H:Haier

C System type-C:Air conditioner;R:Heat pump

24 Nominal capacity in (000) Btu/h

DSEER designation. D=13,E=14

2Design series. 1-1st Generation,2-2nd Generation

V Electric:V=208/230-1-60;C=208/230-3-60;D=460-3-60,Y=575-3-60

ABody style

ERefrigerant type R:R22;E:R410A Example:HC24D2VAE

60

MODEL:

 

HC18D2VAE

HC24D2VAE

HC30D2VAE

HC36D2VAE

HC42D2VAE

HC48D1VAE

HC60D1VAE

Unit Supply Voltage

 

 

 

208/230 60Hz 1PH

 

 

 

Normal Voltage Range

 

 

 

197-253

 

 

 

Minimum Circuit Amps

9.8

11.5

14.8

17.7

20.8

21.6

28.9

(HACR per NEC)

20

25

30

35

40

40

60

Compressor

Rated Load Amps

7.1

8.5

10.7

13.2

15.7

15.7

21.2

 

Locked Running Amps

43

43

54

74

88

84

105

 

Full Load Amps

0.9

0.9

1.4

1.2

1.2

2.0

2.4

Fan Motor

Rated HP

1/7

1/7

1/4

1/5

1/5

1/3

1/2

 

Nominal RPM

1000

1000

1075

1120

1120

960

1000

Liquid Line OD-In(mm)

3/8"[9.52]

3/8"[9.52]

3/8"[9.52]

3/8"[9.52]

3/8"[9.52]

3/8"[9.52]

3/8"[9.52]

Vapor Line OD-In(mm)

3/4"[19.05]

3/4"[19.05]

3/4"[19.05]

3/4"[19.05]

7/8"[22.22]

7/8"[22.22]

7/8"[22.22]

R-410A Charge-Oz(g)

94[2680]

91[2580]

139[3930]

146[4130]

149[423 0]

216[6130]

241[6830]

 

 

21 1/2"*21 1/2"*26 7/8"

21 1/2"*21 1/2"*26 7/8"

24 1/4"*24 1/4"*26 7/8"

24 1/4*24 1/4*30 3/8

24 1/4"*24 1/4"*30 3/8" 30 5/8"*30 5/8"*32 3/16"

30 5/8"*30 5/8"*40"

Net Dimensions-In(mm)

[547*547*683]

[547*547*683]

[616*616*683]

[616*616*771]

[616*616*771]

[779*779*817]

[779*779*1017]

W*D*H

 

 

 

 

 

 

 

 

Shipping Dimensions-In mm)

23"*23"*28 1/2"

23"*23"*28 1/2"

26 7/8"*26 7/8"*28 1/2

26 7/8"*26 7/8"*32"

26 7/8"*26 7/8"*32"

32 1/2" *32 1/2" *33 1/2"

32 1/2" *32 1/2" *41 3/8"

W*D*H

 

[585*585*725]

[585*585*725]

[682*682*725]

[682*682*813]

[682*682*813]

[825*825*851]

[825*825*1051]

Net Weight-Lbs[kg]

150[68]

150[68]

178[81]

183[83]

185[84]

244[111]

290[132]

Approx Shipping Weight-Lbs[kg]

161[73]

161[73]

191[87]

196[89]

198[90]

262[119]

312[142]

Cooling

Outdoor

Indoor

Indoor fan speed

ARI data of indoor

 

 

Cooling Capacity with different outdoor temperature

 

Capacity

SEER

CFM

80

85

90

95

100

105

110

115

HC18D2VAE HB2400VD2M20 M

18000

13

680

20340

19746

19080

18000

17730

17460

17190

16920

HC24D2VAE HB2400VD2M20 H

23000

13

900

25990

25231

24380

23000

22655

22310

21965

21620

HC30D2VAE

HB3600VD2M20

L

29000

13

1125

32770

31813

30740

29000

28565

28130

27695

27260

HC36D2VAE

HB3600VD2M20

H

34000

13

1300

38420

37298

36040

34000

33490

32980

32470

31960

HC42D2VAE

HB4800VD2M22

L

40000

13

1480

45200

43880

42400

40000

39400

38800

38200

37600

HC48D1VAE

HB4800VD2M22

H

47000

13

1580

53110

51559

49820

47000

46295

45590

44885

44180

HC60D1VAE

HB6000VD2M22

H

55500

13

1730

62715

60884

58830

55500

54668

53835

53003

52170

CHECK VALVE

Haier HC60D1VAE, HC48D1VAE, HC42D2VAE, HC36D2VAE, HC30D2VAE Owner’s Manual
Loading...
+ 14 hidden pages