IMPORTANT POINTS ON SERVICE OPERATING SAFETY

Please follow these instructions carefully :

Unplug the unit to avoid any danger from electric shock before disassembling the unit for repair.

If there is any sound of the refrigerant circulating when in operation, avoid touching the cooling coils.

If you need to perform any welding or soldering, be sure you are in a well ventilated area.

Only a qualified professional should perform any welding on the unit.

When repairing the unit, the specifications listed in this manual must be strictly adhered to when replacing any components.

When replacing any electrical components they should be factory approved units.

Be sure that any electrical components are properly wired and in place.

FLOW CHART FOR INSPECTING AND REPAIRING THE UNIT

AIR CONDITIONER

 

 

NO POWER

 

 

POWER TRIPPED

 

 

 

 

WON'T START

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLUG AND SOCKET

ARE LOOSE

TIMER FAILURE

AIR CONDITIONER

 

 

COMPRESSOR WON'T

 

 

 

 

 

 

 

 

WON'T COOL

 

 

START

 

 

PROTECTOR FAILURE

PROPERLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAPACITOR FAILURE

 

 

 

 

 

 

 

WIRING IS LOOSE

REFRIGERANT

LEAKAGE

TROUBLE SHOOTING

THE SYSTEM

CHECK THE POWER

SWITCH

RE-PLUGING THE

POWER SUPPLY CORD

TESTING BY

CHANGE THE SWITCH

ELECTROSCOPE

CHANGE THE

PROTECTOR

CHANGE THE

CAPACITOR

RE-CONNECTING

CHANGE THE AIR CONDITIONER WITH 15 KG/CM2

NITROGEN GAS FROM LOW-PRESSURE SIDE AND DETECT THE LEAKING POINT BY SOAP

USE OXYACETYLENE AND PLUS 5% SILVER SOLDER TO WELD THE

CRACKED POINTS

 

RUNNING THE VACUUM

 

 

CHANGE COOLANT AND

 

 

EVACUATION FOR MORE

 

 

 

 

 

 

PROCEED RUNNING TEST

 

 

THAN 15 MINUTES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RUNNING TEST

- 1 -

TROUBLESHOOTING

Problem

Does not run

Run a short while only

Run but not cool

Analysis

·If the protector trip or fuse is blown.

·Please wait for 3 minutes and start again, protector device may be preventing unit to work.

·If batteries in the remote controller exhausted.

·If the plug is not properly plugged.

·If the set temperature is close to room temperature, you can low the set temperature.

·Air outlet be blocked by obstacle. Take the obstacle away.

·If the door or window open.

·If there is other heater appliance work,

like heater or lamp, etc...

·The air filter is dirty, please clean it.

·Air outlet or intake be blocked.

·Set temperature is too high.

Do not run and water full indicator lights

·Drain the water into a prepared container by the drainage pipe on the rear panel of the unit.

If still doesn't work, please consult a qualified technician.