For purposes of improvement, specifications and
design are subject to change without notice.
●
Please use this service manual with referring to the
operating instructions without fail.
●
Some illustrations using in this service manual are
slightly different from the actual set.
PROFESSIONAL BUSINESS COMPANY
●
本機の仕様は性能改良のため、予告なく変更すること
があります。
●
補修用性能部品の保有期間は、製造打切後 8 年です。
●
修理の際は、必ず取扱説明書を参照の上、作業を行っ
てください。
●
本文中に使用しているイラストは、説明の都合上現物
と多少異なる場合があります。
X0394 V.01 DE/CDM 0807
SAFETY PRECAUTIONS
The following check should be performed for the continued protection of the customer and service technician.
LEAKAGE CURRENT CHECK
Before returning the unit to the customer, make sure you make either (1) a leakage current check or (2) a line to chassis
resistance check. If the leakage current exceeds 0.5 milliamps, or if the resistance from chassis to either side of the
power cord is less than 460 kohms, the unit is defective.
CAUTION
Please heed the points listed below during servicing and inspection.
◎ Heed the cautions!
Spots requiring particular attention when servicing, such
as the cabinet, parts, chassis, etc., have cautions indicated
on labels or seals. Be sure to heed these cautions and the
cautions indicated in the handling instructions.
◎ Caution concerning electric shock!
(1) An AC voltage is impressed on this set, so touching in-
ternal metal parts when the set is energized could
cause electric shock. Take care to avoid electric shock,
by for example using an isolating transformer and
gloves when servicing while the set is energized, unplugging the power cord when replacing parts, etc.
(2)There are high voltage parts inside. Handle with extra
care when the set is energized.
◎ Caution concerning disassembly and
assembly!
Though great care is taken when manufacturing parts from
sheet metal, there may in some rare cases be burrs on the
edges of parts which could cause injury if fingers are
moved across them. Use gloves to protect your hands.
◎ Inspect for safety after servicing!
Check that all screws, parts and wires removed or disconnected for servicing have been put back in their original positions, inspect that no parts around the area that has been
serviced have been negatively affected, conduct an insulation check on the external metal connectors and between
the blades of the power plug, and otherwise check that
safety is ensured.
(Insulation check procedure)
Unplug the power cord from the power outlet, disconnect
the antenna, plugs, etc., and turn the power switch on. Using a 500V insulation resistance tester, check that the insulation resistance between the terminals of the power
plug and the externally exposed metal parts (antenna terminal, headphones terminal, microphone terminal, input
terminal, etc.) is 1MΩ or greater. If it is less, the set must
be inspected and repaired.
CAUTION
Concerning important safety
parts
◎ Only use designated parts!
The set's parts have specific safety properties (fire resistance, voltage resistance, etc.). For replacement parts, be
sure to use parts which have the same properties. In particular, for the important safety parts that are marked z on
wiring diagrams and parts lists, be sure to use the designated parts.
◎ Be sure to mount parts and arrange
the wires as they were originally!
For safety reasons, some parts use tape, tubes or other insulating materials, and some parts are mounted away from
the surface of printed circuit boards. Care is also taken with
the positions of the wires inside and clamps are used to
keep wires away from heating and high voltage parts, so
be sure to set everything back as it was originally.
Many of the electric and structural parts used in the set
have special safety properties. In most cases these properties are difficult to distinguish by sight, and using replacement parts with higher ratings (rated power and
withstand voltage) does not necessarily guarantee that
safety performance will be preserved. Parts with safety
properties are indicated as shown below on the wiring diagrams and parts lists is this service manual. Be sure to replace them with parts with the designated part number.
(1) Schematic diagrams ... Indicated by the z mark.
(2) Parts lists ... Indicated by the z mark.
Using parts other than the designated
parts could result in electric shock, fires or
other dangerous situations.
If wire bundles are untied or moved to perform adjustment or
parts replacement etc., be sure to rearrange them neatly as
they were originally bundled or placed afterward.
Otherwise, incorrect arrangement can be a cause of noise
generation.
(1) Remove top cover. And then connect DC Voltmeter to
the test points TP300 and TP301 of Power Amp
P.W.B.
(2) Connect power cord to AC wall outlet, and turn POW-
ER switch "ON" ( h ).
(3) Right after power on, adjust test points VR403 and
VR404 of Power Amp P.W.B. so that the DC voltmeter
reads 10 ±1mV.
(4) Then after 2 minutes warm up adjust VR403 and
VR404 so that the DC voltmeter reads 10 ±1mV.
(5) And after 10 minutes warm up adjust VR403 and
VR404 so that the DC voltmeter reads 10 ±0.5mV.
● アイドリング電流
(1) トップカバーをはずし、パワーアンプ基板のテスト
ポイント (T.P.300,T.P.301) に DCVoltmeterを接続し
ます。
(2) 電源コードを AC100V(95〜105Vの範囲でも可)
に接続し、電源スイッチを "ON"(h) にします。
(3) 通電後にパワーアンプ基板のテストポイントの電圧
が(10 ± 1mV)になるよう、VR403・VR404 を調
整します。
(4) 2分後にテストポイントの電圧が(10 ± 1mV)にな
るよう、VR403・VR404 を調整します。
(5) 10 分後にテストポイントの電圧が(10 ± 0.5mV)
になるよう、VR403・VR404 を調整します。
7
DN-A300M
DC Voltmeter
DCVoltmete
Power
Trans
Power
Trans
VR404
T.P. 301
VR401
VR404
T.P.301
VR401
Volume
Volume
VR403
T.P. 300
VR402
VR403
T.P.300
VR402
8
DN-A300M
BLOCK DIAGRAM
VOLTA GE:+15V/-15V
VOLTAGE:9.1V
VOLTAGE:+5V
VOLTAGE:+5V
9
DN-A300M
---MEMO---
10
DN-A300M
SEMICONDUCTORS
Only major semiconductors are shown, general semiconductors etc. are omitted to list.
The semiconductor which described a detailed drawing in a schematic diagram are omitted to list.