Whirlpool WED4800X, WED4900X,  , WED4800XQ, WED4900XW User Manual

...
0 (0)
29" Electric Dryer
4"
B
3"*
PRODUCT MODEL NUMBERS
WED4750X, WED4800X, WED4900X, WED4850X, WED4890X, WED4910X
Electrical: This dryer requires a 3 or 4 wire, single
phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specied on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time­delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Water (Steam models only): The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten. Damage to the coupling can result.
Exhaust venting: Exhaust your dryer to the outside. 4" (102 mm) diameter vent is required. Rigid or exible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Hood styles: A & B are recommended.
(102 mm)
A
4" (102 mm)
4" (102 mm)
The Vent system chart provides venting requirements that will help achieve best drying performance.
NOTE: Side and bottom exhaust installation have a 90° turn inside the dryer. To determine maximum exhaust length, add a 90° turn to the total number of elbows when referemcing the chart.
A. Louvered hood B. Box hood C. Angled hood (acceptable)
Vent system chart
Number of 90° elbows
0
1
2
3
4
Type
of vent
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Box/louvered
hoods
64 ft. (20 m)
54 ft. (16.5 m)
44 ft. (13.4 m)
35 ft. (10.7 m)
27 ft. (8.2 m)
C
2½"
(64 mm)
Angled
hoods
58 ft. (17.7 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
OVERALL DIMENSIONS
Dryer dimensions
A. Large opening side-swing door B. Large opening side-swing door
Minimum Required Spacing
18"* (457 mm)
1" (25 mm)
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable.
Most installations require a minimum 5½" (140 mm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”
29"
(737 mm)
1" (25 mm)
1"* (25 mm)
27¾"
(705 mm)
A
A. Recessed area B. Side view - closet or conned area C. Closet door with vents
C. Wide opening side-swing door D. Wide opening hamper door
14" max.* (356 mm)
B
2
48 in. (310 cm )
24 in.
(155 cm )
*
2
2
*
2
C
(76 mm)
3"* (76 mm)
Do not use vent runs longer than specied in vent length chart.
Determine the number of elbows you will need.
Because Whirlpool Corporation policy includes a continuous commitment to improve Dimensions are for planning purposes only. For complete details, see Installation our products, we reserve the right to change materials and specications without notice. Instructions packed with product. Specications subject to change without notice.
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
Use the fewest 90° turns possible.
W10096987
06/2011