Undercounter Dishwasher
PRODUCT MODEL NUMBERS
WDF550SAA WDF550SAF
Electrical Requirements: 120-volt, 60- z, AC-only, 15or 20-amp fused electrical supply. Copper wire only. A timedelay fuse or circuit breaker and separate circuit is recommended.
If direct wiring dishwasher: Use flexible, armored, or nonmetallic, sheathed copper wire
with grounding wire that meets the wiring requirements for your home and local codes and ordinances.
Use a UL Listed or CSA Approved strain relief.
If connecting dishwasher with a power supply cord:
Use Power Supply Cord Kit (Part Number 4317824) marked for use with dishwashers. Follow the kit instructions for installing the power supply cord.
Power supply cord must plug into a grounded 3 prong, outlet, located in the cabinet next to the dishwasher opening. Outlet must meet all localcodes and ordinances.
Water Supply Requirements:A hot water line with 20 to 120 psi (138 to 862 kPa) water pressure. Watertemperature must be 120°F (49°C) water at dishwasher.Use ³⁄ " O.D. copper tubing with compression fitting or flexible braided water supply line (Part Number 4396897RP) (¹⁄ " minimum plastic tubing is not recommended). Use a 90° elbow with ³⁄ " hose connection with rubber washer. Do not solder within 6" (15.2 cm) of the water inlet valve.
Drain Requirements:
■Use the new drain hose supplied with your dishwasher. NOTE: If a longer drain hose is required:
■Use a new drain hose with maximum length of 10 ft (3 m) that meets all current AHAM/IAPMO test standards.
■Use a new drain hose that is resistant to heat and detergent.
■Use a new drain hose that fits the 1" (2.5 cm) drain connector on the dishwasher.
■Connect drain hose to waste tee or disposal inlet above drain trap in house plumbing.
■Connect drain hose to house plumbing 20" (50.8 cm) minimum above the floor.
NOTE: It is recommended that the drain hose either be looped up and securely fastened to the underside of the counter or be connected to an air gap.
■Use a drain air gap if the drain hose is connected to house plumbing lower than 18" (45.7 cm) above the subfloor or floor.
Drain Air Gap
air gap
■ Use ¹⁄ " (1.3 cm) minimum I.D. drain line fittings.
NOTE: Do not connect drain lines from other devices to the dishwasher drain hose.
PRODUCT DIMENSIONS
Side View |
|
|
|
|
|
|
|
|
Rear View |
||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
24" (61 cm)* |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
23 5/9" (59.8 cm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
32¹⁄ " to 34¹⁄ "
(82.6 to 87.6 cm)
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
16 5/8" (42.2 cm) |
|
|
|
|
|
2 ¹⁄ " (6.2 cm) |
||
|
|
|
|||||||
|
|
|
|
|
|
|
|
|
|
* To front of door frame
CABINET CUTOUT DIMENSIONS
34" to 35"
(86.4 cm to 88.9 cm)
A
24" (61 cm) minimum
|
4" |
|
cm) |
2 |
|
. |
|
(10 |
|
6"
(15.2 cm)
24 (61 cm) maximum
A.All surfaces free from intrusions
*Underside of countertop to floor
NOTES:
■Cut holes in shaded area of cabinet walls or floor for plumbing and electrical service.
■ADA installation – 32¹⁄ " (82.5 cm) beneath 34" (86.4 cm) high countertops may be
accomplished by adjusting the toekick and leveling legs.