Upflow/Horizontal
Two-stage Condensing
Gas-Fired Furnace
XV 90
TUY060,080,100,120R9V
Variable Speed Blower
Variable Speed Inducer
PUB. NO. 22-1682-05-0802 (EN)
General
Features
NATURAL GAS MODELS
Central heating furnace designs are certified by the International Approval Services (IAS) for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards.
SAFE OPERATION
The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide extra safety.
QUICK HEATING
Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside.
BURNERS
Multi-port In-shot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners.
INTEGRATED SYSTEM CONTROL
Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./humidifier.
CONDENSATE DRAIN
Built-in trap which can drain from either side when the furnace is installed upflow.
AIR DELIVERY
The variable speed, direct drive blower motor, has sufficient airflow for most heating and cooling requirements, will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed.
SECONDARY HEAT EXCHANGER
The XV 90 has a special type 29-4C™ stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost outside.
STYLING
Heavy gauge steel and “wrap-around” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection in vertical position.
FEATURES AND GENERAL OPERATION
The XV 90 High Efficiency Gas Furnaces employ a Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access.
a.Low energy power venter.
b.Vent proving differential switch.
© 2002 American Standard Inc. All Rights Reserved |
2 |
Pub. No. 22-1682-05-0802 (EN) |
Contents
Feature Summary |
2 |
Features and Benefits |
|
4 |
|
Standard Equipment |
|
Optional Equipment |
|
General Data |
|
6 |
|
TUY060R9V3V |
|
TUY080R9V3V |
|
TUY100R9V4V |
|
TUY120R9V5V |
|
Performance Data |
|
7 |
|
Electrical Data |
|
11 |
|
Field Wiring |
|
|
|
12 |
|
Dimensions |
|
15 |
|
|
|
Pub. No. 22-1682-05-0802 (EN) |
3 |
Features
and Benefits
XV 90 STANDARD EQUIPMENT
•Variable speed indoor blower
•Silicon Nitride Igniter with adaptive heat up
•Variable speed induced draft blower
•Direct/Non-Direct vent option
•Fused 24 volt control circuit
•Manual reset burner safety switches
•Power supply 115/1/60
•Convertible to horizontal on left side
•2-stage gas valve
•PVC venting-1 or 2 pipe option
•Accessory hook-up capability
•Integrated solid state control with self-diagnostics
•Attractive color accents
•Heavy gauge aluminized steel heat exchanger
•Multi-port In-shot burners
•HInged blower door
•Perfect fit door latches
•Insulated blower door
•Gasketed blower door
•Internal filter rack
•Standard filter sizes
•Two tone color
•Complete front service access
•Left/right gas connection
•Adjustable fan off times
•Cleanable high velocity filters
•Optional L.P conversion kit
•Selectable cooling fan off delay eliminates need for BAY24X045 time delay kit
•Lifetime limited primary heat exchanger or secondary heat exchanger warranty to original owner (Residential use)
•5 Year limited parts warranty
4 |
Pub. No. 22-1682-05-0802 (EN) |
Features
and Benefits
OPTIONAL EQUIPMENT
Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling .......................................................................................... |
TAYSTAT241 [ |
] |
|
Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .................................................................................... |
AY28X092 [ |
] |
|
Thermostat, Heating/Cooling Single Stage (Mounts Vertically) .................................................................................... |
BAYSTAT305 [ |
] |
|
..................................................................Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling |
TAYSTAT302C [ |
] |
|
Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling .................................................................. |
TAYSTAT300C [ |
] |
|
Propane Conversion Kit ......................................................................................................................................... |
BAYLPKT210A [ |
] |
|
Electronic Air Filter, “Perfect Fit” Super Efficiency (14-1/2" Wide Gas Furnace) ......................................................... |
TFE145A9FR0 [ |
] |
|
Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2" Wide Gas Furnace) ......................................................... |
TFE175A9FR0 [ |
] |
|
Electronic Air Filter, “Perfect Fit” Super Efficiency (21" Wide Gas Furnace) ............................................................... |
TFE210A9FR0 [ |
] |
|
Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2" Wide Gas Furnace) ......................................................... |
TFE245A9FR0 [ |
] |
|
Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .......................................................... |
TFM145A9FR0 [ |
] |
|
Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .......................................................... |
TFM175A9FR0 [ |
] |
|
Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ................................................................ |
TFM210A9FR0 [ |
] |
|
Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .......................................................... |
TFM245A9FR0 [ |
] |
|
Electronic Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ..................................................... |
TFP145A9FR0 [ |
] |
|
Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ..................................................... |
TFP175A9FR0 [ |
] |
|
Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) .......................................................... |
TFP210A9FR0 [ |
] |
|
Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ..................................................... |
TFP245A9FR0 [ |
] |
|
Coil Enclosure (14-1/2" Wide Cabinets) .................................................................................................................. |
BAYCLE1400C [ |
] |
|
Coil Enclosure (17-1/2" Wide Cabinets) .................................................................................................................. |
BAYCLE1700C [ |
] |
|
Coil Enclosure (21" Wide Cabinets) ........................................................................................................................ |
BAYCLE2100C [ |
] |
|
Coil Enclosure (24-1/2" Wide Cabinets) .................................................................................................................. |
BAYCLE2400C [ |
] |
|
Side Filter Rack ........................................................................................................................................................ |
BAYFLTR200 [ |
] |
|
Filter Kit/Horizontal Conversion TUY060, 080-R ......................................................................................................... |
BAYFLTR203 [ |
] |
|
Filter Kit/Horizontal Conversion TUY100-R ................................................................................................................ |
BAYFLTR204 [ |
] |
|
Filter Kit/Horizontal Conversion TUY120-R ................................................................................................................ |
BAYFLTR205 [ |
] |
|
Filter Accessory Kit Upflow 14.5" Furnaces ............................................................................................................... |
BAYFLTR317 [ |
] |
|
Filter Accessory Kit Upflow 21" Furnaces .................................................................................................................. |
BAYFLTR321 [ |
] |
|
Filter Accessory Kit Upflow 24.5" Furnaces ............................................................................................................... |
BAYFLTR324 [ |
] |
|
High Altitude Switch TUY060R .............................................................................................................................. |
BAYHALT2451 [ |
] |
|
High Altitude Switch TUY080, 100R ...................................................................................................................... |
BAYHALT2461 [ |
] |
|
High Altitude Switch TUY120R .............................................................................................................................. |
BAYHALT2471 [ |
] |
|
Concentric Vent Kit ............................................................................................................................................... |
BAYVENT100A [ |
] |
|
SidewallVentTermination Kit ................................................................................................................................. |
BAYVENT200B [ |
] |
|
Manufactured/Mobile Home Kit ............................................................................................................................. |
BAYMFGH100A [ |
] |
|
1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide. |
|
|
|
Pub. No. 22-1682-05-0802 (EN) |
5 |