Toshiba RAS-13UKPX-T2, RAS-13UAX-T2, RAS-10UAX-T2, RAS-10UKPX-T2, RAS-07UKPX-T2 Service Manual

...
0 (0)
SERVICE MANUAL
AIR-CONDITIONER
SPLIT WALL TYPE
FILE NO. SVM-02003
RAS-13UKPX-T2 / RAS-13UAX-T2 RAS-10UKPX-T2 / RAS-10UAX-T2 RAS-07UKPX-T2 / RAS-07UAX-T2
RAS-13UKX / RAS-13UAX
RAS-10UKX / RAS-10UASX
Apr., 2002
07 Class
FILE NO. SVM-02003
– 1 –
CONTENTS
1. SPECIFICATIONS
2. CONSTRUCTION VIEWS
2-1 Indoor Unit (RAS-13UKPX-T2, RAS-10UKPX-T2, RAS-07UKPX-T2) 2-2 Indoor Unit (RAS-13UKX, RAS-10UKX) 2-3. Outdoor Unit (RAS-13UAX-T2, RAS-13UAX) 2-4. Outdoor Unit (RAS-10UAX-T2) 2-5. Outdoor Unit (RAS-10UASX, RAS-07UAX-T2)
3. WIRING DIAGRAM
4. SPECIFICATION OF ELECTRICAL PARTS
4-1 Indoor Unit 4-2 Outdoor Unit (RAS-13UAX-T2) 4-3 Outdoor Unit (RAS-13UAX) 4-4 Outdoor Unit (RAS-10UAX-T2, RAS-10UASX) 4-5 Outdoor Unit (RAS-07UAX-T2)
5. REFRIGERATION CYCLE DIAGRAM
5-1 RAS-13UKPX-T2 / RAS-13UAX-T2 5-2 RAS-10UKPX-T2 / RAS-10UAX-T2 5-3 RAS-07UKPX-T2 / RAS-07UAX-T2 5-4 RAS-13UKX / RAS-13U AX 5-5 RAS-10UKX / RAS-10UASX
6. CONTROL BLOCK DIAGRAM
6-1 RAS-13UKPX-T2 / RAS-13UAX-T2
RAS-10UKPX-T2 / RAS-10UAX-T2 RAS-07UKPX-T2 / RAS-07UAX-T2
6-2 RAS-13UKX / RAS-13U AX
RAS-10UKX / RAS-10UASX
7. OPERATION DESCRIPTION
7-1 Outline of Air Conditioner Control 7-2 Description of Operation Circuit 7-3 Hi POWER Mode 7-4 High-Temperature Limit Control 7-5 Low-Temperature Limit Control 7-6 Auto Restart Function 7-7 Filter Check Lamp
FILE NO. SVM-02003
– 2 –
8. INSTALLATION PROCEDURE
8-1 Safety Cautions 8-2 Installation Diagram of Indoor and Outdoor Units 8-3 Installation 8-4 Indoor Unit 8-5 Outdoor Unit 8-6 How to Set Remote Control Selector Switch 8-7 Others
9. TROUBLESHOOTING CHART
9-1 Troubleshooting Procedure 9-2 Basic Check Items 9-3 Primary Judgement 9-4 Self-Diagnosis by Remote Control (Check Code) 9-5 Troubleshooting Flowcharts 9-6 Troubleshooting for Remote Control (Including The Indoor P.C. Board)
10. PARTS REPLACEMENT
10-1 Indoor Unit 10-2 Outdoor Unit (RAS-13UAX-T2, RAS-13UAX) 10-3 Outdoor Unit (RAS-10UAX-T2) 10-4 Outdoor Unit (RAS-07UAX-T2, RAS-10UASX)
11. EXPLODED VIEWS AND PARTS LIST
11-1 Indoor Unit (E-Parts Assy) 11-2 Indoor Unit (RAS-13UKPX-T2, RAS-10UKPX-T2, RAS-07UKPX-T2) 11-3 Indoor Unit (RAS-13UKX, RAS-10UKX) 11-4 Outdoor Unit (RAS-13UAX-T2) 11-5 Outdoor Unit (RAS-10UAX-T2) 11-6 Outdoor Unit (RAS-13UAX) 11-7 Outdoor Unit (RAS-10UASX, RAS-07UAX-T2)
– 3 –
FILE NO. SVM-02003
RAS-13UKPX-T2 RAS-10UKPX-T2 RAS-07UKPX-T2
RAS-13UKX / RAS-13UAX RAS-10UKX / RAS-10UASX
RAS-13UAX-T2 RAS-10UAX-T2 RAS-07UAX-T2
ITEM Cooling
Capacity
220V 220V 220V 220V 240V 220V 240V
kW 3.65 2.70 2.10 3.70 3.75 2.60 2.60
Phase 1
Power source V 220 220 – 240
Hz 50 Power consumption kW 1.05 0.80 0.60 1.25 1.29 0.88 0.93 Power factor % 98 96 92 98 95 95 94 Running Indoor A 0.15 current Outdoor A 4.70 3.65 2.80 5.66 5.53 4.05 3.98 Starting current A 25 11 24 16 Moisture removal lit/h 2.0 1.2 0.8 2.0 1.2 Noise Indoor (H/M/L) dB 41/35/31 39/33/26 38/32/26 41/35/31 39/33/26
Outdoor (220-240V) dB 49 46 44 47-48 45-46
Refrigerant
Name of refrigerant R-22 Rated amount kg 0.80 0.85 0.57 0.78 0.65
Refrigerant control Capillary tube
Gas side size mm ∅12.70 ∅9.52 ∅12.70 ∅9.52 Connection type Flare connection Liquid side size mm ∅6.35
Interconnection
Connection type Flare connection
pipe
Maximum length
m 15*
1
10*
1
15*
1
10*
1
(One way) Maximum height
m6 5 6 5
difference
INDOOR
RAS-13UKPX-T2 RAS-10UKPX-T2 RAS-07UKPX-T2 RAS-13UKX RAS-10UKX
Height mm 275
Dimensions Width mm 790
Depth mm 208 Net weight kg 10 Evaporator type Finned tube Indoor fan type Cross flow fan
High fan m3/h 630 570 630 Air volume Medium fan m3/h 550 490 460 550 490
Low fan m3/h 460 370 340 460 370 Fan motor output W 30 Air filter Honeycomb woven filter with PP frame
OUTDOOR
RAS-13UAX-T2 RAS-10UAX-T2 RAS-07UAX-T2 RAS-13UAX RAS-10UASX
Height mm 538 530 538 530 Dimensions Width mm 780 770 660 780 660
Depth mm 300 200 240 300 240 Net weight kg 41 30 26 37 28 Condenser type Finned tube Outdoor fan type Propeller fan Airflow volume m3/h 1830 1700 1280 1700 1900 1420 1520 Fan motor output W 42 30 20 30
Compressor
Model
RM5515FNE96 RM5510GNE94 PH80T1-4C PH160T2-4L2 PH102T1-4C
Output W 1100 750 605 1100 750 Safety device Fuse, Overload relay Louver type Automatic louver Usable outdoor temperature range °C 21 ~ 43
1. SPECIFICATIONS
MODEL
– 4 –
FILE NO. SVM-02003
Note : 1
Capacity is based on the following temperature conditions.
Note : 2
Charge refrigerant according to the table below.
RAS-10UKPX-T2 / RAS-10UAX-T2
Refrigerant RAS-07UKPX-T2 / RAS-07UAX-T2
RAS-10UKX / RAS-10UASX
*1 No need to charge
15m or less 10m or less
refrigerant
Temperature
Condition
JIS C9612-1994
Cooling
Indoor unit inlet air temperature
(DB) 27°C
(WB) 19°C
Outdoor unit inlet air temperature
(DB) 35 °C
(WB) 24 °C
RAS-13UKX-T2 / RAS-13UAX-T2
RAS-13UKX / RAS-13UAX
FILE NO. SVM-02003
– 5 –
2. CONSTRUCTION VIEWS
2-1. Indoor Unit (RAS-13UKPX-T2, RAS-10UKPX-T2, RAS-07UKPX-T2)
Connecting pipe (0.33m) (For 07,10 series ; Flare 9.52
For 13 series ; Flare 12.7)
Knock out system
Back body
Front panel
Air outlet
Air inlet
Air filter
Heat exchanger
Knock out system
660
275
790
48
208
48
48
26
4519040
32
64
590
320
620
235 235
215 215
9090
275
45
150150 160160
120 80
53
660
Hanger
Hanger
Hanger
Hanger
Hanger
Drain hose (0.54m)
Connecting pipe (0.43m) (Flare 6.35)
For stud bolt (8~10)
For stud bolt (6)
Installation plate outline
Center line
Minimum distance to ceiling
170 or more
Minimum distance to ceiling
170 or more
65 or more
Minimum distance to ceiling
Wireless remote control
57 18
160
FILE NO. SVM-02003
6
2-2. Indoor Unit (RAS-13UKX, RAS-10UKX)
Front panel
Back body
Knock out system
660
275
48
Air outlet
Air inlet Air Filter
790
Heat exchanger
Knock out system
660
48
48
208
64
80590
320
620
235
215 215
9090 150150 160160
26
32
4540 190
275
45
235
120
53
Hanger
Hanger
Hanger
Hanger
Hanger
Drain hose (0.54m)
Connecting pipe (0.43m)
(Flare 6.35) Connecting pipe (0.33m) (For 07,10 series ; Flare 9.52
For 13 series ; Flare 12.7)
For stud bolt (8~10)
Installation plate outline
Center line
Minimum distance to ceiling
170 or more
Minimum distance to ceiling
170 or more
65 or more
Minimum distance to ceiling
Wireless remote control
57 18
160
FILE NO. SVM-02003
7
2-3. Outdoor Unit (RAS-13UAX-T2, RAS-13UAX)
538
325
325
52.5
23
301
325
300
Handle
25Drain outlet
Electric parts cover
Service port
61
54
325 (pitch)
(8.5)
(8.5)
342
100 or more
100 or more
600 or more
600 or more
Installation dimension
600
Air inlet
Air outlet
8-6 hole (for fixing outdoor unit)
Liquid side (Flare 6.35)
Gas side (Flare 12.7)
120
11x14 hole
6 hole
R10
600
Detail Drawing
50 36
A
A
4-11x14 hole (for 8-10 anchor bolt)
600
100
130
780
90
59
27
Fan guard
420
Z
View
Z
4x11x14 Long holes (for 8-10 anchor bolt)
FILE NO. SVM-02003
8
2-4. Outdoor Unit (RAS-10UAX-T2)
600 85
36
111
25 Drain hole
50
30
216
230
8-6 Holes (For fixing the outdoor unit)
4-11x14 Long holes (For anchor bolt 8-10)
Gas side (flare 9.52)
Liquid side (flare 6.35)
111
A
600
R10
50
36
25
216
230
11x14 Hole
6 Hole
Handle
11
525
530
5
268
Fan guard
420
770
59
89
200
11
12
Electric parts cover
Z
54 62
Access for charging
250
Z
View 600
45 or more
Air inlet
600 or more
(Minimum distance of the wall)
4-11x14 Long holes
400 or more
Air outlet
Center port
230
100 or more
Air inlet
Visible outline of the product
A
Detail Drawing
Mounting dimension of anchor bolt
268
770
59
89
(For anchor bolt 8-10)
FILE NO. SVM-02003
9
2-5. Outdoor Unit (RAS-10UASX, RAS-07UAX-T2)
Z
Cover PV
54
273.5
59.5
420
500 97.5
(11)
297
(12.5)273.5 (pitch)
660
242
56
A Detail Drawing (Back Leg)
660
50 36
R 15
R 5.5
273.5
265
6 Hole
B Detail Drawing (Front Leg)
50
36
R 15
660
265
273.5
6 Hole
11x14 Hole
A
B
Z View
97
25Drain outlet
2-11x14 hole (for 8-10 anchor bolt)
Fan guard
530
Liquid side
(Flare 6.35) Gas side (Flare 12.7)
Service port
126
48
325
100 or more
100 or more
600 or more
600 or more
Installation dimension
600
Air inlet
Air outlet
4x
11x14 Long holes (for 8-10 anchor bolt)
FILE NO. SVM-02003
– 10 –
3. WIRING DIAGRAM
CN13
CN07
BLK
GRN&YEL
POWER TERMINAL BLOCK
POWER SUPPLY SINGLE PHASE 220-240V , 50 Hz
BRW BLU
BLK
WHI
GRN&YEL
OUTDOOR TERMINAL BLOCK
INDOOR TERMINAL BLOCK
WHI
DSA
VARISTOR
RY01
4
3
F01
C15
L01
IC03
C58
R48
R46
R47
CR03
D38
C01 R01
DB01
POWER SUPPLY CIRCUIT
C02
DC 12V DC 5V
R21 VARISTOR
MAIN P.C. BOARD
MCC-862
T6.3A 250V
P04
SG01
CN04
INDOOR
OUTDOOR
1 2
1 2
CAPACITOR
CAPACITOR
RED
RED
RED
WHI
WHI
BLKCBLK
BLK
GRN & YEL CHASSIS
RED
FAN MOTOR
OVER LOAD RELAY
R
S
YEL
135
GRY
BRW
BLK
WHI
RED
CN01CN03
THERMO SENSOR
(TA)
HEAT
EXCHANGER
SENSOR
(TC)
CN10CN11
AC FAN MOTOR
BLK
BLK
1
35
1
35
24 24
6 6
1
3
5
1
3
5
1
2
1
2
3 3
112
2
BLK
BLK
112
2
: : : : : : : : :
:
:
BROWN RED WHITE YELLOW BLUE BLACK GRAY PINK ORANGE GREEN & GREENGRN
YELLOW
BRW
RED
WHI YEL BLU BLK
GRY
PNK
ORN
GRN&YEL
COLOR IDENTIFICATION
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
BLU
WHI
YEL
CN25
PNK
PNK
YEL
YEL
YEL
WHI
INFRARED RAYS RECEIVE AND INDICATION PARTS
4 5 6 7 8 9
10 11
3
1
2
4 5 6 7 8 9
10 11
3
1
2
4 5 6 7 8 9
10 11
3
1
2
2 1
3
5
4
2 1
3
5
4
1
2
1
2
R22
N
L
Louver motor
GRN&YEL
FILE NO. SVM-02003
– 11 –
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit
4-2. Outdoor Unit (RAS-13UAX-T2)
No. Parts name Type Specifications
Output (Rated) 1100W , 2poles , 1 phase, 220 – 240V, 50Hz
1 Compressor RM5515FNE96 Winding resistance () C-R C-S
(at 20°C) 2.43 3.78 Output (Rated) 42W , 6poles, 1 phase, 220 – 240V, 50/60Hz
2 Fan motor (for outdoor) HF-240-42B Winding resistance (Ω) Red-Black White-Black
(at 20°C) 176.2 290.5
3
Running capacitor
DS451205BPQA AC 450V, 2.0µF
(for fan motor)
4
Running capacitor
DS371306CPNB AC 370V, 30µF
(for compressor)
5 Overload relay LAAO00A U/T: 9.0A (80°C), OPEN: 135±5°C, CLOSE: 75±11°C
No. Parts name Type Specifications
1 Fan motor (for indoor) MMF-240-20-4A-1 AC Motor with 135°C thermo fuse 2 Thermo sensor (TA-sensor) ——— 10k at 25°C 3 Switching transformer (T01) SWT-47 4 Microcontroller unit (IC30) TMP87CM40AN-2C67 5 Heat exchanger sensor
——— 10k at 25°C
(TC-sensor) 6 Line filter (L01) LC*SS11V-06270 27mH, 600mA 7 Bridge rectifier (DB01) D3SBA60 4A, 600V 8 Capacitor (C02) KMH400VSSN47M22S 47µF, 400V 9 Fuse (F01) TSCR6.3A T6.3A, 250VAC
10 Varistor (R21, R22) 15G561K 560V 11 Resistor (R01) RF-2TK5R6 5.6, 2W 12 Louver motor MP24GA 12VDC 13 Relay (Comp., RY01) DI12D1 Rating 20A/AC250V, 12VDC
FILE NO. SVM-02003
– 12 –
4-3. Outdoor Unit (RAS-13UAX)
4-4. Outdoor Unit (RAS-10UAX-T2, RAS-10UASX)
No. Parts name Type Specifications
Output (Rated) 1100W , 2poles , 1 phase , 220 – 240V, 50Hz
1 Compressor PH160T2-4L2 Winding resistance () C-R C-S
(at 20°C) 2.43 3.78 Output (Rated) 30W, 6poles, 1 phase , 220 – 240V, 50/60Hz
2 Fan motor (for outdoor) HF-240-30B Winding resistance (Ω) Red-Black White-Black
(at 20°C) 245 388
3
Running capacitor
DS501155BPQA AC 500V, 1.5µF
(for fan motor) 4
Running capacitor
DS371356CPNB AC 370V, 35µF
(for compressor) 5 Overload relay LAAO00A U/T: 9.0A (80°C), OPEN: 135±5°C, CLOSE: 75±11°C
No. Parts name Type Specifications
Output (Rated) 800W, 2poles, 1 phase, 220 – 240V, 50Hz
1 Compressor Winding resistance (Ω) C-R C-S
(at 20°C) 2.159 3.899 Output (Rated) 750W, 2poles, 1 phase, 220 – 240V, 50Hz Winding resistance (Ω) C-R C-S (at 20°C) 3.88 5.06 Output (Rated) 30W, 6poles, 1 phase, 220 – 240V, 50Hz
2 Fan motor (for outdoor) HF-240-30B Winding resistance (Ω) Red-Black White-Black
(at 20°C) 245 388
3
Running capacitor
DS501155BPQA AC 500V, 1.5µF
(for fan motor) 4
Running capacitor
DS371256CPNB AC 370V, 25µF
(for compressor) 5 Overload relay LPAP960B U/T: 6.1A (80°C), OPEN: 135±5°C, CLOSE: 78±11°C
RM5510GNE94
(RAS-10UAX-T2)
PH102T1-4C
(RAS-10UASX)
FILE NO. SVM-02003
– 13 –
4-5. Outdoor Unit (RAS-07UAX-T2)
No. Parts name Type Specifications
Output (Rated) 750W, 2poles, 1 phase, 220 – 240V, 50Hz
1 Compressor PH80T1-4C Winding resistance ( ) C-R C-S
(at 20°C) 4.80 8.37 Output (Rated) 20W, 6poles, 1 phase, 220 – 240V, 50Hz
2 Fan motor (for outdoor) HF-240-20B Winding resistance (Ω) Red-Black White-Black
(at 20°C) 387.3 466.2
3
Running capacitor
DS501155BPQA AC 500V, 1.5µF
(for fan motor) 4
Running capacitor
DS371156CPNB AC 370V, 15µF
(for compressor) 5 Overload relay JMRA99269-9200 U/T: 4.2A (80°C), OPEN: 135±5°C, CLOSE: 69±11°C
FILE NO. SVM-02003
– 14 –
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Standard 0.48 13.0 High 27/19 35/24
Cooling Overload 0.60 18.0 High 32/23 43/26
Low temperature 0.42 2.0 Low 21/15 21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
5. REFRIGERATION CYCLE DIAGRAM
5-1. RAS-13UKPX-T2 / RAS-13UAX-T2
Heat exchanger
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan Outdoor unit
Capillary tube
1.7x500S
RM5515FNE96
Cooling
Mark( )means check points of Gas Leak.
O.D.:12.7mm O.D.:6.35mm
Cooling
Packed valve
(12.7)
Packed valve
(6.35)
0.39m (Connecting pipe) 12.7
0.49m (Connecting pipe) 6.35
T1
P
Refrigerant R-22 : 0.80 kg.
FILE NO. SVM-02003
15
5-2. RAS-10UKPX-T2 / RAS-10UAX-T2
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan Outdoor unit
RM5510GNE94
Cooling
Mark( )means check points of Gas Leak.
O.D.:9.52mm O.D.:6.35mm
Cooling
Packed valve
(9.52)
Packed valve
(6.35)
0.39m (Connecting pipe) 9.52
0.49m (Connecting pipe) 6.35
T1
P
Refrigerant R-22 : 0.85 kg.
Evaporator
Capillary tube
1.5x1200S
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Standard 0.58 13.0 High 27/19 35/24
Cooling Overload 0.64 17.0 High 32/23 43/26
Low temperature 0.39 2.0 Low 21/15 21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
FILE NO. SVM-02003
16
5-3. RAS-07UKPX-T2 / RAS-07UAX-T2
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Standard 0.45 14.0 High 27/19 35/24
Cooling Overload 0.69 18.0 High 32/23 43/26
Low temperature 0.40 3.0 Low 21/15 21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
Heat exchanger
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan Outdoor unit
Capillary tube
1.5x1200S
PH80T1-4C
Cooling
Mark( )means check points of Gas Leak.
O.D.: 9.52mm O.D.:6.35mm
Cooling
Packed valve
(˘9.52)
Packed valve
(6.35)
0.39m (Connecting pipe) ˘9.52
0.49m (Connecting pipe) 6.35
T1
P
Refrigerant R-22 : 0.57 kg.
FILE NO. SVM-02003
17
5-4. RAS-13UKX / RAS-13UAX
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Standard 0.45 13.0 High 27/19 35/24
Cooling Overload 0.62 18.0 High 32/23 43/26
Low temperature 0.40 2.0 Low 21/15 21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan Outdoor unit
PH160T2-4L2
Cooling
Mark( )means check points of Gas Leak.
O.D.: 12.7mm O.D.:6.35mm
Cooling
Packed valve
(˘12.7)
Packed valve
(6.35)
0.39m (Connecting pipe) ˘12.7
0.49m (Connecting pipe) 6.35
T1
P
Refrigerant R-22 : 0.78 kg.
Evaporator
Capillary tube
1.7x700S
FILE NO. SVM-02003
18
5-5. RAS-10UKX / RAS-10UASX
Indoor unit
Cross flow fan
Cooling
Cooling
Compressor
Condenser
Propeller fan Outdoor unit
PH102T1-4C
Cooling
Mark( )means check points of Gas Leak.
O.D.:9.52mm O.D.:6.35mm
Cooling
Packed valve
(9.52)
Packed valve
(6.35)
0.39m (Connecting pipe) 9.52
0.49m (Connecting pipe) 6.35
T1
P
Refrigerant R-22 : 0.65 kg.
Evaporator
Capillary tube
1.5x1400S
Accumulator
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Standard 0.52 13.0 High 27/19 35/24
Cooling Overload 0.65 18.0 High 32/23 43/26
Low temperature 0.40 3.0 Low 21/15 21/15
50Hz
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
FILE NO. SVM-02003
– 19 –
6. CONTROL BLOCK DIAGRAM
6-1. RAS-13UKPX-T2 / RAS-13UAX-T2, RAS-10UKPX-T2 / RAS-10UAX-T2,
RAS-07UKPX-T2 / RAS-07UAX-T2
REMOTE CONTROL
Heat Exchange sensor
Main Unit Control Panel M.C.U.
Functions
Operation
Display
Timer
Display
Filter Sign
Display
Hi Power
Sign Display
Fan Only
Sign Display
Indoor Fan
Motor
Louver
Motor
Louver
ON/OFF
Signal
Compressor
ON/OFF
Signal
Power Supply
Circuit
Noise Filter Relay Driver, Louver Driver
Relay
RY01
220-240 V~, 50Hz
Compressor, Outdoor Fan Motor
Initiallizing Circuit
Clock Frequency Oscillator Circuit
Louver Control
3-minutes Delay at Restart
for Compressor
Processing (Temperature Processing)
Motor Revolution Control
Timer
Thermo. Sensor
Infrared Rays Signal Reciver
Remote Control
Operation (START/STOP) Operation Mode Selection
AUTO, COOL, DRY, FAN ONLY
Temperature Setting Fan Speed Selection
ON TIMER Setting
OFF TIMER Setting
Louver Auto Swing
Louver Direction Setting
ECO
Hi power
Filter Reset
Infrared Rays
FILE NO. SVM-02003
20
6-2. RAS-13UKX / RAS-13UAX, RAS-10UKX / RAS-10UASX
REMOTE CONTROL
Remote Control
Operation (START/STOP) Operation Mode Selection
AUTO, COOL, DRY, FAN ONLY
Temperature Setting
Fan Speed Selection
ON TIMER Setting
OFF TIMER Setting
Louver Auto Swing
Louver Direction Setting
ECO
Infrared Rays
Heat Exchange sensor
Main Unit Control Panel M.C.U.
Functions
Operation
Display
Timer
Display
Filter Sign
Display
Fan Only
Sign Display
Indoor Fan
Motor
Louver
Motor
Louver
ON/OFF
Signal
Compressor
ON/OFF
Signal
Power Supply
Circuit
Noise Filter Relay Driver, Louver Driver
Relay
RY01
220-240 V~, 50Hz
Compressor, Outdoor Fan Motor
Initiallizing Circuit
Clock Frequency Oscillator Circuit
Louver Control
3-minutes Delay at Restart
for Compressor
Processing (Temperature Processing)
Motor Revolution Control
Timer
Thermo. Sensor
Infrared Rays Signal Reciver
FILE NO. SVM-02003
– 21 –
7. OPERATION DESCRIPTION
7-1-1. Louver control
(1)Vertical air flow louver
Position of veritcal air flow louver is automatically controlled according to the operation mode. Besides, position of vertical air flow louver can be arbitrarily set by pressing [FIX] button. The louver position which is set by [FIX] button is stored in the microcomputer, and the louver is automatically set at the stored position for the next operation.
(2)Swing
If [SWING] button is pressed when the indoor unit is in operation, the vertical air flow louver starts swinging. When [FIX] button is pressed, it stops swinging.
7-1-2. Indoor fan control (AC Fan motor)
(1)The indoor fan is operated by the stepless speed
change AC motor.
(2)For air flow level, speed of the indoor fan motor is
controlled in five steps (LOW, LOW
+
, MED, MED
+
and HIGH). If AUTO mode is selected, the fan motor speed is automatically controlled by the difference between the preset temperature and the room temperature.
Table 7-1-1
7-1. Outline of Air Conditioner Control
This is a fixed capacity type air conditioner, which uses a AC motor for an indoor fan. The AC motor drive circuit is mounted in the indoor unit. And electrical parts which operate the compressor and the outdoor fan motor, are mounted in the outdoor unit. The air conditioner is mainly controlled by the indoor unit controller. The controller operates the indoor fan motor based upon commands transmitted by the remote control and transfers the operation commands to the outdoor unit controller. The outdoor unit controller receives operation commands from the indoor unit, and operates the outdoor fan motor and the compressor.
(1) Role of indoor unit controller
The indoor unit controller receives the operation commands from the remote control and executes them.
Temperature measurement at the air inlet of the indoor heat exchanger by the indoor temperature sensor
Temperature setting of the indoor heat exchanger by the heat exchanger sensor
Louver motor control
Indoor fan motor operation control
LED display control
Transferring of operation commands to the
outdoor unit
Receiving of information of the operation status and judging of the information or indication of error
LOW
+
=
MED+=
LOW+MED
2
MED+HIGH
2
RAS-13UKPX-T2 RAS-10UKPX-T2 RAS-07UKPX-T2
Model Motor speed Air flow level Motor speed Air flow level Motor speed Air flow level
(rpm) (m3/h) (rpm) (m3/h) (rpm) (m3/h)
HIGH 1,300 630 1,300 630 1,200 570 Cooling MED+ 1,220 600 1,180 560 1,100 520 and MED 1,150 550 1,050 490 1,000 460 Fan only LOW+ 1,070 500 950 430 900 400
LOW 1,000 460 850 370 800 340
RAS-13UKX RAS-10UKX
Cooling HIGH 1,300 630 1,300 630 and MED 1,150 550 1,050 490 Fan only LOW 1,000 460 850 370