TANDBERG D13841.01 User Manual

TANDBERG 3G Gateway
User Manual
Software version R1.0
This document is not to be reproduced in whole or in part without permission in writing from:
D13841.01
Trademarks and copyright
All rights reserved. This document contains information that is proprietary to TANDBERG. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, electronically, mechanically, by photocopying, or otherwise, without the prior written permission of TANDBERG. Nationally and internationally recognized trademarks and trade names are the property of their respective holders and are hereby acknowledged.
Copyright (c) 1992, 1993, The Regents of the University of California. All rights reserved. This code is derived from software contributed to Berkeley by Christos Zoulas of Cornell University. Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
Redistributions of source code must retain the above copyright notice, this list of
conditions and the following disclaimer.
Redistributions in binary form must reproduce the above copyright notice, this list of
conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
All advertising materials mentioning features or use of this software must display the
following acknowledgement:
o This product includes software developed by the University of California,
Berkeley and its contributors.
Neither the name of the University nor the names of its contributors may be used to
endorse or promote products derived from this software without specific prior written permission.
This software is provided by the Regents and contributors as is and any express or implied warranties, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose are disclaimed. In no event shall the Regents or contributors be liable for any direct, indirect, incidental, special, exemplary, or consequential damages (including, but not limited to, procurement of substitute goods or services; loss of use, data or profits; or business interruption) however caused and on any theory of liability, whether in contract, strict liability, or tort (including negligence or otherwise) arising in any way out of the use of this software, even if advised of the possibility of such damage.
Disclaimer
The information in this document is furnished for informational purposes only, it is subject to change without prior notice, and should not be construed as a commitment by TANDBERG. The information in this document is believed to be accurate and reliable, however TANDBERG assumes no responsibility or liability for any errors or inaccuracies that may appear in this document, nor for any infringements of patents or other rights of third parties resulting from its use. No license is granted under any patents or patent rights of TANDBERG.
ii
This document was written by the Research and Development Department of TANDBERG, Norway. We are committed to maintain a high level of quality in all our documentation. Towards this effort, we welcome you to Contact us with comments and suggestions regarding the content and structure of this document.
COPYRIGHT © 2005, TANDBERG
iii
Environmental Issues
Thank you for buying a product which contributes to a reduction in pollution, and thereby helps save the environment. Our products reduce the need for travel and transport and thereby reduce pollution. Our products have either none or few consumable parts (chemicals, toner, gas, paper). Our products are low energy consuming products.
TANDBERGs Environmental Policy
TANDBERGs Research and Development is continuously improving TANDBERGs
products towards less use of environmentally hazardous components and substances as well as to make the products easier to recycle.
TANDBERG's products are Communication Solutions. The idea of these solutions is
to reduce the need for expensive, time demanding and polluting transport of people. Through peoples use of TANDBERGs products, the environment will benefit from less use of polluting transport.
TANDBERGs wide use of the concepts of outsourcing makes the company itself a
company with a low rate of emissions and effects on the environment.
TANDBERGs policy is to make sure our partners produce our products with minimal
influence on the environment and to demand and audit their compatibility according to applicable agreements and laws (national and international).
Environmental Considerations
Like other electronic equipment, the TANDBERG 3G Gateway contains components that may have a detrimental effect on the environment. TANDBERG works continuously towards eliminating these substances in our products.
Printed-wiring boards made of plastic, with flame-retardants like Chloride or Bromide.  Component soldering that contains lead.  Smaller components containing substances with possible negative environmental
effect.
After the products end of life cycle, it should be returned to authorized waste handling and should be treated according to National and International Regulations for waste of electronic equipment.
iv
Operator Safety Summary
For your protection, please read these safety instructions completely before operating the equipment and keep this manual for future reference. The information in this summary is intended for operators. Carefully observe all warnings, precautions and instructions both on the apparatus and in the operating instructions.
Warnings
Caution risk of explosion if battery is replaced by an incorrect type. Dispose of used
batteries according to the instructions.
Water and moisture - Do not operate the equipment under or near water - for
example near a bathtub, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool or in areas with high humidity.
Cleaning - Unplug the apparatus from the wall outlet before cleaning or polishing. Do
not use liquid cleaners or aerosol cleaners. Use a lint-free cloth lightly moistened with water for cleaning the exterior of the apparatus.
Ventilation - Do not block any of the ventilation openings of the apparatus. Install in
accordance with the installation instructions. Never cover the slots and openings with a cloth or other material. Never install the apparatus near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
Grounding or Polarization - Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician.
Power-Cord Protection - Route the power cord so as to avoid it being walked on or
pinched by items placed upon or against it, paying particular attention to the plugs, receptacles, and the point where the cord exits from the apparatus.
Attachments - Only use attachments as recommended by the manufacturer.  Accessories - Use only with a cart, stand, tripod, bracket, or table specified by the
manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
Lightning - Unplug this apparatus during lightning storms or when unused for long
periods of time.
Servicing - Do not attempt to service the apparatus yourself as opening or removing
covers may expose you to dangerous voltages or other hazards, and will void the warranty. Refer all servicing to qualified service personnel.
Damaged Equipment - Unplug the apparatus from the outlet and refer servicing to
qualified personnel under the following conditions:
When the power cord or plug is damaged or frayed  If liquid has been spilled or objects have fallen into the apparatus  If the apparatus has been exposed to rain or moisture  If the apparatus has been subjected to excessive shock by being dropped, or
the cabinet has been damaged
If the apparatus fails to operate in accordance with the operating instructions
v
Contact us
If you have any questions, comments or suggestions, please see the Online Support service at www.tandberg.net.
It is also possible to send a fax or mail to the attention of: Product and Sales Support
TANDBERG P.O. Box 92 1325 Lysaker Norway Tel: +47 67 125 125 Fax: +47 67 125 234
vi
1 Introduction
Table of Contents
1 Introduction................................................................................................................................8
1.1 The TANDBERG 3G Gateway..............................................................................................10
1.1.1 3G GATEWAY Capacity – typical scenarios ............................................................11
2 Installation ...............................................................................................................................12
2.1 Unpacking.............................................................................................................................13
2.2 Connecting cables ................................................................................................................14
2.3 3G Gateway Configuration....................................................................................................15
3 Using the 3G Gateway ............................................................................................................18
3.1 Call Overview........................................................................................................................18
3.2 Dial from UMTS.....................................................................................................................20
3.3 Dial from IP ...........................................................................................................................23
4 View System Status ................................................................................................................25
4.1 PRI/BRI Status......................................................................................................................26
4.2 H.323 Status .........................................................................................................................29
4.3 System Information...............................................................................................................30
4.4 Available Resources .............................................................................................................31
5 Configure the Gateway............................................................................................................32
5.1 System Configuration............................................................................................................33
5.1.1 PRI Configuration......................................................................................................33
5.1.2 BRI configuration ......................................................................................................35
5.2 IP Configuration ....................................................................................................................37
5.3 H.323 Configuration..............................................................................................................39
5.4 SNMP Configuration .............................................................................................................41
5.5 Miscellaneous Configuration.................................................................................................43
5.6 Software Upgrade.................................................................................................................45
5.7 Services Configuration..........................................................................................................47
5.7.1 IVR............................................................................................................................49
5.7.2 examples...................................................................................................................50
6 Appendices..............................................................................................................................51
vii
TANDBERG 3G Gateway User Manual
1 Introduction
The TANDBERG 3G Gateway enables sites on IP and UMTS Handsets to participate in meetings with eachother with the quality and reliability found in all TANDBERG equipment.
IP Services and Procedures
Service Prefix  Load balance
UMTS Services
The TANDBERG 3G Gateway offers a variety of UMTS dial-in services:
Direct Inward Dialing (DID) - The destination endpoint is determined from the dialed
number
Interactive Voice Response (IVR) - The destination endpoint can be selected via touch
tones
Security
Secure Access - support XML/SOAP over HTTPS, Web (HTTP) encrypted password and
the services that can be disabled
Video Quality
H.263 video compression
Audio Quality
AMR, G.711 audio compression  Support AMR bitrate 4.75 kbit – 12.2 kbit
Interoperability
Worldwide compatibility with standards-based videoconferencing systems  Compatible with all available WCDMA H324M video telephony capable handsets who
support DTMF tones
Management Interfaces
SOAP Simple Object Access Protocol is a lightweight protocol for exchange of information in a
decentralized, distributed environment
XML Extensible Markup Language is a flexible way to create common information formats and
share both the format and the data on the World Wide Web, intranets, and elsewhere. This functionality can be used by management systems like the TANDBERG Management Suite to control the 3G Gateway
HTTP Web-interface for system management, call management such as call transfer,
diagnostics and software uploads
HTTPS Hypertext Transfer Protocol over Secure Socket Layer is a Web protocol that encrypts
and decrypts user page requests as well as the pages that are returned by the Web server. It uses Secure Socket Layer (SSL) as a sublayer under its regular HTTP application layering. HTTPS uses port 443 instead of HTTP port 80 in its interactions with the lower layer, TCP/IP. SSL uses a 40-bit key size for the RC4 stream encryption
8
1 Introduction
algorithm, which is considered an adequate degree of encryption for commercial exchange
Network and Features
Up to 30 video sites can be connected at the same time  Call rate of 64 Kbit on ISDN side and 109kbps on IP side for each call is supported through
the 3G Gateway
Video IVR  Selecting IP endpoint from address book
9
TANDBERG 3G Gateway User Manual
1.1 The TANDBERG 3G Gateway
Front view
The front panel provides 4 LAN interfaces, an LCD display, RS232 interface and control buttons.
Rear view
BRI interface
PRI interface
The back panel provides one PRI interface or 4 BRI interfaces depending on the configuration and one power switch/connector. Next to the PRI RJ-45 there are 4 LEDs. In normal working condition the green LED will be lit. Functions of the LEDs are:
Green: Normal operation
10
1 Introduction
Red Alarm or Loss of signal (LOS) indicates that there is no signal and thus no framing info received. The same effect will be obtained by pulling out the PRI cable. This may also be caused by a broken connector in the receive (RX) part of the cable.
Yellow Alarm or Remote Alarm Indicator (RAI) means that the 3G Gateway is receiving framing info, but in this framing info the other side tells the 3G Gateway that it is not reading the gateways transmitted framing info. Typically, this may be a broken connector in the transmit (TX) part of the PRI cable. This could also indicate weak or noisy signal in the transmit (TX) part of the PRI cable.
Blue Alarm indicates that the received frames are not synchronized properly. No LEDs lite indicates that layer one framing is working (right protocol like for example EURO
ISDN selected), but that however there is a problem at layer 2 caused by for example a CRC4 configuration mismatch.
1.1.1 3G GATEWAY Capacity – typical scenarios
Due to the fixed bandwidth of UMTS video telephony every call will be limited to 64 kbit. This offers a capacity of 30 simultaneous calls through a single PRI 3G Gateway or 8 calls through a 4 x BRI 3G Gateway. Due to audio transcoding (AMR to G.711) the bandwidth at IP side is 109 kbit/s per session, 64 Kbit G.711 audio and 45 kbit H.263 video. Depending on the option package and version of the 3G Gateway (PRI or BRI) the amount of simultaneous 3G calls can be less then 30 or 23 for T1.
.
11
TANDBERG 3G Gateway User Manual
2 Installation
Precautions:
Never install telephone wiring during a lightning storm.  Never install telephone jacks in wet locations unless the jack is specifically designed for
wet locations.
Never touch uninstalled telephone wires or terminals unless the telephone line has been
disconnected at the network interface.
Use caution when installing or modifying telephone lines.  Avoid using a telephone (other than a cordless type) during an electrical storm. There
may be a remote risk of electrical shock from lightning.
Do not use the telephone to report a gas leak in the vicinity of the leak.  The socket outlet shall be installed near to the equipment and shall be easily accessible.  Never install cables without first switching the power OFF.  This product complies with directives: LVD 73/23/EC, EMC 89/366/EEC, R&TTE
99/5/EEC.
This product complies with the standards GR-63-CORE and GR-1089-CORE and is
NEBS approved by UL .For NEBS compliance, the product should be installed in the following manner:
- There should be a clearance of 9.1cm between the product and any other product mounted in the rack.
12
2.1 Unpacking
5 Configure the Gateway
To avoid damage to the unit during transportation, the 3G Gateway is delivered in a special shipping box, which should contain the following components:
User Manual and other documentation on CD.  Rack-ears, screws and screwdriver.  Cables:
o Power cable o One ISDN PRI cables or 4 ISDN BRI cables depending on the version o Ethernet cable o RS232 cable
TANDBERG 3G Gateway
Installation site preparations
Make sure that the 3G Gateway is accessible and that all cables can be easily
connected.
For ventilation: Leave a space of at least 10cm (4 inches) behind the 3G Gateways rear
panel and 10cm (4 inches) in front of the front panel.
The room in which you install the 3G Gateway should have an ambient temperature
between 0ºC and 35ºC (32ºF and 95ºF) and between 10% and 90% non-condensing relative humidity.
Do not place heavy objects directly on top of the 3G Gateway.  Do not place hot objects directly on top, or directly beneath the 3G Gateway.  Use a grounded AC power outlet for the 3G Gateway.  You will need a CSU (Channel Service Unit) between your system and the PRI line from
your network provider.
Make sure that it is possible to receive and to make Mobile(h324M) video calls from
behind this line. Check this with your network operator!
If you are behind a PABX make sure that the PBABX is capable of routing Mobile
(H324M) video calls.
13
TANDBERG 3G Gateway User Manual
2.2 Connecting cables
Power cable
Connect the system power cable to an electrical distribution socket.
ISDN PRI or BRI cables
The E1/T1 cable should be connected to a CSU (Channel Service Unit). You will need a CSU between your 3G Gateway and the PRI line from your network provider.
LAN cable
To use the 3G Gateway on IP, connect a LAN cable from the LAN 1 connector on the 3G Gateway to your network. The LAN 2, 3 and 4connectors are not used and should be left open.
RS 232 cable
To control the 3G Gateway using the dataport, connect an RS 232 cable between the 3G Gateways RS 232 connector and the COM-port on a PC.
14
5 Configure the Gateway
2.3 3G Gateway Configuration
The 3G Gateway requires some basic configurations before it can be used. It will be necessary to find the IP-address and to create the dial-in and dial-out services program the ISDN-PRI Line numbers.
It is possible to use the front panel LCD display or the serial RS232 cable. Using the RS232 cable, follow the instructions below:
1. Connect the RS232 cable between the 3G Gateway and a PC and then switch on the 3G Gateway.
2. Start a terminal program on the PC and configure it to: 115200, 8, 1, None.
3. a. To assign a static IP-address, type Xconf ip Assigment: Static” ’ and Xconf Ip
address <IPAddr>’.
b. To assign an IP Subnetmask, type Xconf ip address subnetmask <subnetmask>’. c. To assign an IP Gateway address, type Xconf ip address gateway <gateway IP-
address>’.
4. Restart the 3G Gateway.
5. Start a WEB browser and enter the IP-address of the 3G Gateway. Default password:
‘TANDBERG’.
6. To configure the 3G Gateway for UMTS dial in, enter PRI or BRI numbers and dial in number(s). For details, see the PRI Configuration and the Services Configuration section.
7. To configure the gateway for IP dial in, register the gateway to a gatekeeper and enter H.323 services. For details, see chapter 5.7, Services Configuration..
The LCD panel makes it possible to configure and the Check the IP settings and to reboot the system. The front panel LCD menu items are displayed below. Due to the limited amount of buttons the function will differ on every menu level also depending on the function of the menu (reading or editing). Appendix 0 contains a detailed description of every level and functions of every button. The usage of the buttons is designed in an intuitive way and should not result in any problems.
IP Settings
MainMenu IP settings IP Information Commands
IP Address IP Netmask IP Default GW
IP Information
IP Address
Commands
Reboot
15
TANDBERG 3G Gateway User Manual
To configure the IP number follow the instructions below:
1. Press any key to get the main menu.
2. IP settings should be displayed.
3. Press [ENTER] to access the IP settings menu.
4. Us the [UP/DOWN] key to select IP Address.
5. Press [ENTER] to access the IP address editing menu.
6. Press [ENTER] again to get a cursor.
7. Use up down keys to navigate between the different digits.
8. After selecting a digit use the [ENTER] key in combination with the [UP/DOWN] key to change the digit value.
9. When finished editing use [ESC] key to go to the confirm change menu.
10. Use the [UP/DOWN] key to select yes or no and [ENTER] to confirm.
11. Use [ESC] key to navigate back to the main menu.
Note that DHCP assigned IP-addresses are supported by the TANDBERG 3G Gateway (factory default),
3G Gateway start-up
To start the 3G Gateway, please make sure that the power cable is connected, and press the power switch button at the back side to 1’.
On the front panel of the system the power indicator LED, marked Pwr, will turn GREEN.
Accessing the 3G Gateway
You may access the 3G Gateway by entering the IP-address of the 3G Gateway in a standard WEB-browser. You will then be asked to enter a password. It is not necessary to enter User Name. The default password for the 3G Gateway is TANDBERG. Remember that the password is case sensitive. Note that it also possible to use SSH and Telnet to configure the 3G Gateway.
16
5 Configure the Gateway
Note that the password can be changed in System Configuration, Misc. See also the section 5.5
Miscellaneous Configuration’.
17
Loading...
+ 37 hidden pages