Schneider Electric BX800CI, BX1100CI User Manual

Installation and Operation Manual
bu001c
Back-UPS

Inventory Safety and General Information

BX800CI/BX1100CI
This unit is intended for indoor use only. Do not operate this unit in direct sunlight, in contact with fluids, or where there is excessive dust or humidity. Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation. The battery typically lasts for two to five years. Environmental factors impact battery life. Elevated ambient temperatures, poor quality AC power, and frequent short duration discharges will shorten battery life. Connect the Back-UPS power cable directly into a wall outlet. Do not use surge protectors or extension cords.
* 2 IEC jumpers for BX1100CI.

Connect the Battery

Connect the battery connector prior to using the UPS.
Pull the battery connector handle down. Then push the connector into the UPS. The battery charges fully during the first 10 hours while the Back-UPS is
operating on AC power. Do not expect full battery runtime capability during the initial charge period. There are no serviceable parts in the Back-UPS. Do not attempt to op en or
repair the Back-UPS as this will void the warranty. The battery in this unit is not replaceable. Contact APC through the Web site www.apc.com, for customer support.

Installation

bu043e
bu227f
Circuit Breaker Push to Reset
Battery Backup + Surge Protection
Battery Connector
bu227e
Circuit Breaker Push to Reset
Battery Conn ector

Connect the Equipment

Battery Connector
Battery Backup + Surge Protection outlets
Battery Backup + Surge Protection
Battery Backup + Surge Protection
Battery Backup + Surge Protection
Connect the battery. Refer to “Connect the Battery” on page 1.
These outlets provide battery backup power to connected equipment for a limited period of time during power outages and voltage fluctuations.
The Battery Backup +Surge Protection outlets provide battery power to connected equipment only when the Back-UPS is turned on.
Connect critical equipment such as a computer, computer monitor, modem or other data sensitive devices to these outlets.
Do not connect aquarium equipment, laser printers, paper shredders, sump pumps, or fans to these outlets as the modified sine wave output of the Back-UPS may cause these devices to experience a decrease in performance.
Do not connect surge strips or surge protectors to these outlets.
AC power inlet Connect the Back-UPS to AC power.
Circuit breaker Use to reset the system after an overload condition has occurred causing the circuit breaker to trip.
Back-UPS BX800CI/BX1100CI Installation and Operation2

Operation

Turn On the Back-UPS

Press the POWER ON/OFF button located on the front of the Back-UPS. The On Line LED will illuminate green and a single short beep will be audible to indicate that the Back-UPS is providing protection for connected equipment.

Status Indicators

Status LED Indicator
Power On
The Back-UPS is supplying AC power to connected equipment.
On Battery
The Back-UPS is supplying battery power to battery backup outlets.
Low Battery warning
The Back-UPS is supplying battery power to the battery backup outlets and the battery is near a total discharge state.
Replace Battery
The battery is disconnected. The battery needs to be charged or replaced.
Overload Shutdown
While operating on battery power an overload condition has occurred in one or more of the battery backup outlets.
Sleep Mode
While operating on battery power the battery is completely discharged. The Back-UPS will awaken once AC power is restored.
Overload Alarm
The equipment connected to the Back-UPS is drawing more power than the voltage rating allows.
Audible Indicator
On
The On Line LED illuminates green.
The On Line LED illuminates green. The LED is not illuminated during the beeps.
The On Line LED flashes green.
•The Battery LED
flashes red.
Battery and On Line
LEDs flash alternately.
None Constant tone The Back-UPS is turned off.
None The Back-UPS
The Battery LED illuminates red.
None N/A
Back-UPS beeps 4 times every 30 seconds.
The Back-UPS emits rapid beeping. (once every second)
Constant tone The Back-UPS is turned off.
beeps once every four seconds.
Constant tone Alarm stops when nonessential
Audible Indicator
Terminates
The beeping stops when AC power is restored or the Back-UPS is turned off.
The beeping stops when AC power is restored or the Back-UPS is turned off.
• AC power is restored
• AC power is not restored within 32 seconds
• The Back-UPS is turned off
equipment is disconnected from the Battery Backup outlets.
Back-UPS BX800CI/BX1100CI Installation and Operation 3