Samsung AW12P1HEA, AWT12P1HBA, AWT12P1HEA, AWT18P1HEA, AW09P1HEA User Manual

...
0 (0)

OWNER'S INSTRUCTIONS

MANUAL DE INSTRUCCIONES

MANUEL D'UTILISATION

MANUAL DE INSTRUÇÕES

ISTRUZIONI PER L'USO

AW07P1HBA/BB AW09P1HBA/BB

AW07P1HEA/EB AW09P1HDA/DB

AW09P1HAA/AB AW09P1HEA/EB

AW12P1HAA/AB AW12P1HEA/EB

AW12P1HBA/BB AWT12P1HBA/BB

AW12P1HDA/DB AWT12P1HEA/EB

AW14P1HBA/BB AW24P1HBA/BB/BC/BD

AW18P1HEA/EB AW24P1HEA/EB

AW18P1HBA/BB AWT18P1HEA/EB/EC

AWT24P1HEA/EB/EC/ED

Window-type Room Air Conditioner (Cool)

Acondicionador de airea doméstico sistema de tipo ventana (Reirigeración)

ClimatiseurdetypeFenêtre (Refroidissement)

OarCondicionadodeWindow-Type(Refrigeracçã)

Condizionatored'ariaperambientidafinestra(Raffreddamento)

ITALIANO PORTUGUÊS FRANÇAIS ESPAÑOL ENGLISH

E S F P I DB98-20383A(4)

AQ07S2GE IB_E_15110 04/2/2 15:35 Page 2

Register your product at www.samsung.com/global/register

Safety Precautions

The following safety precautions must be taken when using your air conditioner.

WARNING

Risk of electric shock. Can cause injury or death. Disconnect all

remote electric power supplies before servicing, installing or cleaning.

 

This must be done by the manufacturer or its service agent or a similar

 

qualified person in order to avoid a hazard.

DURING OPERATION

DISPOSING OF THE UNIT

OTHERS

Users of this product are cautioned not to attempt repair of this product at their own discretion. Instead, they are requested to directly contact a designated service center or the outlet at which the product was purchased.

Never spill any kind of liquid into the unit. Should this happen, unplug or main switch off the unit and contact an authorized service center.

Do not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury. Keep children away from the unit.

Do not place any obstacles in front of the unit.

Do not spray liquid of any kind into the indoor unit. Should this happen, switch off the breaker used for your air conditioner and contact your installation specialist.

Make sure that the unit is correctly ventilated at all times: Do not place clothing or other materials over it.

If the wireless remote control will not be used for a long time, remove the batteries. (If applicable)

When using a wireless remote control, the distance should not be more than 7 meters from the air conditioner. (If applicable)

The air conditioner must be plugged into its own specific power source, which must be installed in compliance with national wiring,earthing and safety regulations.

If the power cord is damaged in any way, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

This device must be installed according to the national electrical rules.

The appliance must be installation that the plug should be easily accessible after installation.

If the fuse on PC board is broken please change it with the type of T 3.15A 250V.

The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less than 3.5mm. Such means for disconnection must be incorporation in the fixed wiring.

Before throwing out the device, it is necessary to pull back the battery cells and get rid of them safely for recycling reasons.

When you need to dispose of the unit, consult your dealer. If pipes are removed incorrectly, refrigerant may blow out and come into contact with your skin,causing injury. Releasing refrigerant into the atmosphere also damages the environments.

Please recycle or dispose of the packaging material for this product in an environmentally responsible manner.

Never store or ship the air conditioner upside down or sideways to avoid damage to the compressor.

The appliance is not intended for use by young children or infirm persons without supervision: Young children should be supervised to ensure that they do not play with the appliance.

Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency.

E-2

ENGLISH

Contents

PREPARING YOUR AIR CONDITIONER

 

Safety Precautions

2

Air Conditioning Unit-Main Parts and Control Panel

4

OPERATION YOUR AIR CONDITIONER

 

CoolingYour Room

5

AiringYour Room

6

Switching the Air Conditioner Off

6

Adjusting the Air Flow Direction Horizontally

7

Adjusting the Air Flow Direction Vertically

7

RECOMMENDATIONS FOR USE

 

Temperature and Humidity Ranges

7

Cleaning Your Air Conditioner

8

Solving Common Problems

9

Technical Specitications

10

INSTALLATION

11

The illustrations in the step-by-step procedures use four different symbols:

CAUTION

"The high inrush current of the starting compressor motor can have adverse effects to the operation of other equipment under unfavorable mains conditions.This equipment does not comply with the relevant technical standards for the limitation of voltage fluctuations and flicker."

Before connection this equipment to the power supply system, please report to your suply authority and obtain the consent.

Do not connect other electric appliances to the same supply lines.

AW18**

The maximum permissible system impedance at the power junction box is 0.24 ohms. Usually, the maximum permissible mains impedance will not be exceeded when the branch to the power outlet is fed from a junction box with a rated current of 32A.

E-3

Samsung AW12P1HEA, AWT12P1HBA, AWT12P1HEA, AWT18P1HEA, AW09P1HEA User Manual

Air Conditioning Unit - Main Parts and Control Panel

The desing and shape are subject to change according to the model.

Air inlet(Inside)

The air filter is located in side

Air Outlet

Power plug

Inner air flow blades (right/left orientation)

Outer air flow blades (up/down orientation)

Air inlet (Outside)

Ventilation lever

Power Cable

The type of the power plug may differ according to the type of local power supply.

Operating mode

Temperature

selection dial

control dial

 

Coolest

 

Air flow blade swing switch

E-4

Cooling Your Room

ENGLISH

You must select the Cool mode if you wish to lower the temperature in your room. Y ou can also set the fan speed.

1Select the operating mode and fan speed.

To cool your room with a... Set the operating mode

 

 

selection dial to...

 

 

High fan speed

HI COOL

 

 

Between HIGH and LOW

MED COOL

 

 

Low fan speed

LOW COOL

 

 

Result:

The air conditioner starts up in Cool mode.

 

The fan starts up at the speed selected.

You can change modes at any time.

2To adjust the temperature, turn the temperature control dial to the desired position.

Possible temperatures: Between 18 C and 29 C inclusive.

Result:

The air conditioner starts cooling if the room temperature is

 

higher than the selected temperature.

3 To control the direction of the air flow, refer to page 7