Samsung AW12P1AC, AW18P1A, AW18P1BC, AW12P1A, AW12P1AA Manual

0 (0)

USER'S MANUAL

AW07P1 Series

AW09P1 Series

AW12P1 Series

AWT12P1 Series

AW14P1 Series

AW18P1 Series

AWT18P1 Series

AW24P1 Series

AWT24P1 Series

Window-type Room Air Conditioner (Cooling)

ITALIANO PORTUGUÊS FRANÇAIS ESPAÑOL ENGLISH

E S F P I DB98-27658A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DB98-20383A.indd 15

 

2006-10-26 19:05:08

 

 

 

 

 

 

 

 

 

 

 

 

 

Register your product at www.samsung.com/global/register

Safety Precautions

The following safety precautions must be taken when using your air conditioner.

 

WARNING

Risk of electric shock. • Can cause injury or death. • Disconnect all

 

remote electric power supplies before servicing, installing or cleaning.

 

 

 

 

 

 

• This must be done by the manufacturer or its service agent or a similar

 

 

 

qualified person in order to avoid a hazard.

 

 

 

 

 

 

 

 

DURING OPERATION

DISPOSING OF THE UNIT

OTHERS

E-

uUsers of this product are cautioned not to attempt repair of this product at their own discretion. Instead, they are requested to directly contact a designated service center or the outlet at which the product was purchased.

uNever spill any kind of liquid into the unit. Should this happen, unplug or main switch off the unit and contact an authorized service center.

uDo not insert anything between the air outlet blades because the inner fan may be damaged and could cause injury. Keep children away from the unit.

uDo not place any obstacles in front of the unit.

uDo not spray liquid of any kind into the indoor unit. Should this happen, switch off the breaker used for your air conditioner and contact your installation specialist.

uMake sure that the unit is correctly ventilated at all times: Do not place clothing or other materials over it.

uIf the wireless remote control will not be used for a long time, remove the batteries. (If applicable)

uWhen using a wireless remote control, the distance should not be more than 7 meters from the air conditioner. (If applicable)

uThe air conditioner must be plugged into its own specific power source, which must be installed in compliance with national wiring,earthing and safety regulations.

uIf the power cord is damaged in any way, it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.

uThis device must be installed according to the national electrical rules.

uThe appliance must be installation that the plug should be easily accessible after installation.

uIf the fuse on PC board is broken please change it with the type of T 3.15A 250V.

uThe breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no less than 3.5mm. Such means for disconnection must be incorporation in the fixed wiring.

uBefore throwing out the device, it is necessary to pull back the battery cells and get rid of them safely for recycling reasons.

uWhen you need to dispose of the unit, consult your dealer. If pipes are removed incorrectly, refrigerant may blow out and come into contact with your skin,causing injury. Releasing refrigerant into the atmosphere also damages the environments.

uPlease recycle or dispose of the packaging material for this product in an environmentally responsible manner.

uNever store or ship the air conditioner upside down or sideways to avoid damage to the compressor.

uThe appliance is not intended for use by young children or infirm persons without supervision: Young children should be supervised to ensure that they do not play with the appliance.

uMax current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DB98-20383A.indd 2

 

2006-10-26 19:04:57

 

 

 

 

 

 

 

 

 

 

 

 

 

ENGLISH

 

 

Contents

 

PREPARING YOUR AIR CONDITIONER

 

 

n

Safety Precautions.........................................................................................

2

 

n Air Conditioning Unit-Main Parts and Control Panel......................................

4

OPERATION YOUR AIR CONDITIONER

 

 

n

Cooling Your Room........................................................................................

5

 

n

Airing Your Room...........................................................................................

6

 

n Switching the Air Conditioner Off...................................................................

6

 

n Adjusting the Air Flow Direction Horizontally.................................................

7

 

n Adjusting the Air Flow Direction Vertically.....................................................

7

RECOMMENDATIONS FOR USE

 

 

n Temperature and Humidity Ranges...............................................................

7

 

n Cleaning Your Air Conditioner.......................................................................

8

 

n

Solving Common Problems...........................................................................

9

INSTALLATION.............................................................................................

10

The illustrations in the step-by-step procedures use four different symbols:

PRESS

PUSH

IMPORTANT

NOTE

CAUTION

“The high inrush current of the starting compressor motor can have adverse effects to the operation of other equipment under unfavorable mains conditions. This equipment does not comply with the relevant technical standards for the limitation of voltage fluctuations and flicker.”

Before connection this equipment to the power supply system, please report to your suply authority and obtain the consent.

Do not connect other electric appliances to the same supply lines.

AW18

The maximum permissible system impedance at the power junction box is 0.24 ohms. Usually, the maximum permissible mains impedance will not be exceeded when the branch to the power outlet is fed from a junction box with a rated current of 32A.

E-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DB98-20383A.indd 3

 

2006-10-26 19:04:58

 

 

 

 

 

 

 

 

 

 

 

 

 

Samsung AW12P1AC, AW18P1A, AW18P1BC, AW12P1A, AW12P1AA Manual

Air Conditioning Unit - Main Parts and Control Panel

The design and shape are subject to change according to the model.

 

Air Outlet

 

Inner air flow blades

 

(right/left orientation)

Air inlet (Inside)

Outer air flow blades

 

(up/down orientation)

The air filter is

 

located in side

Air inlet (Outside)

Ventilation lever

 

Power Cable

 

The type of the power plug

Power plug

may differ according to the

 

type of local power supply.

Operating mode

Temperature

selection dial

control dial

 

Coolest

 

Air flow blade

 

swing switch

E-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DB98-20383A.indd 4

 

2006-10-26 19:04:58

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling Your Room

ENGLISH

You must select the Cool mode if you wish to lower the temperature in your room.You can also set the fan speed.

1 Select the operating mode and fan speed.

To cool your room with a...

Set the operating mode

 

selection dial to...

 

 

High fan speed

HI COOL

Between HIGH and LOW

MED COOL

Low fan speed

LOW COOL

Result: The air conditioner starts up in the Cool mode.

The fan starts up at the speed selected.

You can change modes at any time.

2To adjust the temperature, turn the temperature control dial to the desired position.

Possible temperatures: Between 18 °C and 29 °C inclusive.

Result:

The air conditioner starts cooling if the room temperature is

 

higher than the selected temperature.

3 To control the direction of the air flow, refer to page 7.

E-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DB98-20383A.indd 5

 

2006-10-26 19:04:59

 

 

 

 

 

 

 

 

 

 

 

 

 

Loading...