RISCO Group GT 600 User Manual

4 (1)

GT 600 601 Control Panel

User Instructions

GT 600 601

User Manual

Contents

 

User Information .........................................................

2

Introduction ...................................................................

3

User Code Types..........................................................

3

Setting The System ......................................................

6

Setting Unsetting via Keyswitch....................................

7

Unsetting The System ..................................................

8

Part Setting The System...............................................

8

Quick Part Setting.........................................................

9

Area Setting ..................................................................

10

Removing Zones...........................................................

11

Testing The System......................................................

12

Viewing The Event Log.................................................

13

Changing The Chime Status.........................................

14

Programming User Codes ............................................

16

Programming Time & Date ...........................................

19

Vo-Comm (if fitted)........................................................

20

Using Vo-Comm ...........................................................

23

Messages From Vo-Comm...........................................

23

User Initiating Remote Access (Optional).....................

24

Resetting After An Alarm ..............................................

25

Setting Engineer Authorisation .....................................

28

Setting The System With Mains Fail.............................

30

Re-setting the Display After a Mains Fail......................

31

Setting the System With a Line Fault............................

32

System G-Tag...............................................................

33

Advanced Code Programming (Control Codes) ...........

35

Advanced Setting Unsetting Using Group Area Codes

38

Setting Using Group Area Codes .................................

38

Programming Group Area User Codes.........................

39

Setting Using Group Master & Main Codes.................

42

Unsetting Using Group Area Codes .............................

43

Unsetting Using Group Master & Main Codes..............

43

Adding Areas To a System with Area(s) Already Set ...

44

Display Blanking ...........................................................

45

End User Training.........................................................

45

Testing / Servicing Your System...................................

45

Keypad Alert .................................................................

46

Keypad Tamper ............................................................

46

System Tampers...........................................................

46

System Attributes..........................................................

47

User Chart ....................................................................

51

Page 1

RISCO Group GT 600 User Manual

User Manual

 

GT 600 601

 

User Information

 

 

 

 

 

 

 

Customer Name:-

 

 

 

 

 

 

 

Customer Address:-

 

 

 

 

 

 

 

 

 

 

 

System Information

 

 

 

No of Keypads

 

 

 

Keypad 1 Location

 

Type

 

Keypad 2 Location

 

Type

 

Keypad 4 Location

 

Type

 

Keypad 5 Location

 

Type

 

Keypad 6 Location

 

Type

 

Keypad 7 Location

 

Type

 

 

 

 

 

 

 

 

 

Keyswitch 1 Location, Area 1,

User Code No.

 

Keyswitch 2 Location, Area 2,

User Code No.

 

Keyswitch 3 Location, Area 3,

User Code No.

 

Keyswitch 4 Location, Area 4,

User Code No.

 

Keyswitch 5 Location, Area 5,

User Code No.

 

Keyswitch 6 Location, Area 6,

User Code No.

 

Keyswitch 7 Location, Area 7,

User Code No.

 

External Proximity Reader 1 Location

External Proximity Reader 2 Location

Internal Proximity Reader 1 Location

Internal Proximity Reader 2 Location

Installation Company Name:-

Installation Company Address:-

Installation Company: Tel.

Fax.

E-mail

 

Web Address

 

Other Information:-

 

Note: THIS SECTION MUST BE COMPLETED BY THE INSTALLATION ENGINEER.

Page 2

GT 600 601

User Manual

Introduction

The GT 600 Control Panel is capable of controlling up to 40 zones with 31 individual Users. The GT 601 Control Panel is capable of controlling up to 136 zones with 99 individual Users. Control of the system is via Remote Keypads (RKPs). Control is also possible via Proximity Reader(s). Facility is provided for Central Station and/or VoComm (message communication) to inform of system status and alarm events. VoComm messages may be sent to standard land line telephones or mobile telephones. Please take time to familiarise yourself with the type of equipment fitted to your premises as it will prove invaluable whilst using this manual.

IMPORTANT USER INFORMATION

If the Control Panel is non EN then all displays will be shown and “ENTER CODE CHECK” will not be displayed.

All information displays will remain until cleared by the User.

User Code Types

Master Level User Code BS / EN2 (default) - 5678

EN3 (default)- 005678

Several types of User Codes are available on the GT 600 / 601, and each type allows different levels of access. The GT 600 Control Panel can have a total of 31 User codes programmed by a Master Level User Code. User number 1 will always be a Master Level User but the remaining User Codes may be programmed to the required level of access. The GT 601 Control Panel can have a total of 99 User codes programmed by a Master Level User Code. Again, the User number 1 will always be a Master Level User but the remaining 98 User Codes may be programmed to the required level of access.

You will be advised by your installation company on the code length required.

The Code Levels should be viewed as four groups, Global codes that give system control, Area codes that give area control, Group codes giving control of more than 1 area and Control codes giving control off outputs.

The User Code levels available and the functions available for the levels are:-

Global Code Levels (affecting full system)

Set Only

Only Allows for the setting of the system.

Main

Allows Setting, Part Setting, Area Setting, Zone Remove, System

 

Test, Unsetting.

Master

Allows Setting, Part Setting, Area Setting, Zone Remove, System

 

Test, Viewing the Log, Chime On/Off, Program User Codes, Set

 

Time/Date, Unsetting.

Page 3

User Manual

GT 600 601

Area Code Levels (affecting areas only)

Area 1

Allows Area 1 Setting, Area 1 Part Setting, Area 1 Unsetting.

Cleaner

Full System Setting (from unset system), Cleaner Area Unsetting

 

(from set system), Cleaner Part Set (from part cleaner set system).

Area 2

Allows Area 2 Setting, Area 2 Part Setting, Area 2 Unsetting.

Area 3

Allows Area 3 Setting, Area 3 Part Setting, Area 3 Unsetting.

Areas 4 - 7

(601 Control Panel only). Allows Areas 4 - 7 Setting, Areas 4 - 7

 

Part Setting, Areas 4 - 7 Unsetting.

Main 1

Allows Area 1 Setting, Area 1 Part Setting, Area 1 Zone Remove,

 

Area 1 Test, Area 1 Unsetting.

Main 2

Allows Area 2 Setting, Area 2 Part Setting, Area 2 Zone Remove,

 

Area 2 Test, Area 2 Unsetting.

Main 3

Allows Area 3 Setting, Area 3 Part Setting, Area 3 Zone Remove,

 

Area 3 Test, Area 3 Unsetting.

Mains 4 - 7

(601 Control Panel only). Allows Areas 4 - 7 Setting, Areas 4 - 7

 

Part Setting, Areas 4 - 7 Zone Remove, Areas 4 - 7 Test,

 

Areas 4 - 7 Unsetting.

Group Code Levels (affecting group or groups of areas)

Group Master

Allows Setting, Part Setting, Area Setting, Zone Remove, System

 

Test, Viewing the Log, Chime On/Off, Program User Codes, Set

 

Time/Date, Unsetting. Will also allow setting/unsetting of individual

 

areas for greater system control

Group Main

Allows Setting, Part Setting, Area Setting, Zone Remove, System

 

Test, Unsetting. Will also allow setting/unsetting of individual

 

areas for greater system control

Group Area

Allows group setting/unsetting/part setting of a selected group of

 

areas.

Group Area Codes are classed as an Advanced User Function as they allow for greater flexibility on systems that are using multiple areas. For details on using Group Area Codes please refer to the section Advanced Setting and Unsetting Using Group Area Codes on page 38.

Page 4

GT 600 601

User Manual

Control Code Levels (affecting an output)

Control

Allows an output that has been pre-programmed by the installation

 

company to be operated.

 

May also have an attribute of Can or Can’t Unset. Control level

 

codes can never Set a system.

Page 5

User Manual

GT 600 601

Setting The System

1)With the display showing:-

2)Enter your User code.

01 JAN 18 : 58 : 01

(Followed by YES if a Master or Main type code has been used). The display will show:-

and a continuous exit tone will sound.

(See “Pre Exit Check” note below and/or “Pre Exit Check in Wireless Installations” on page 7)

EXIT ! 1

 

All Zones ON

15

Time will count down

Note: Count down in display depends on the setting mode programmed by the Engineer.

3)Exit the premises via the authorised exit route.

(The exit tone will change if any detectors are violated during exit).

4)Once the premises are secure listen, (from outside the protected area) that the exit tone returns to the continuous tone.

5)Wait until the exit tone finishes before leaving.

Note: 1 Setting the system with an area code will set only the area(s) associated with that code.

Note: 2 Setting an unset system with a cleaner code will set the full system.

Note: 3 To Set the system with cleaner on site Press CODE YES YES 0

Pre Exit Check

At the start of the setting procedure any non exit routes that are open will sound a fault tone. The display will show, for example:-

If the fault clears within 20 seconds then the exit will begin, otherwise the display will return to Day (Unset) Mode.

Zone 008 12hr

All Zones ON

Page 6

GT 600 601

User Manual

Pre Exit Check in Wireless Installations

This feature is only applicable in wireless fitted installations. A zone (PIR, door contact etc) will be rendered ‘Not Ready’ if it has not been heard by your Control Panel for 20 minutes.

When attempting to set your system, the Control Panel

Keypad may show one of the following:- Zone ###

Can’t Set! Check

Note: ### is the Zone Number

Or

Front Door

Can’t Set! Check

To Set the System

1)Enter your User code:

2)Proceed to the Zone/Detector stated and operate the device. (See note below).

3)Repeat the setting procedure on page 6.

Note: Door Contact - Activate it by opening and closing the door. PIR - Activate it by walking in front of the PIR

Shock Detector - Active it by tapping until the GREEN LED is seen.

Setting & Unsetting the System via a Keyswitch

One of two types of keyswitch(es) may have been fitted to your system.

Normal

To set the system with a normal keyswitch, insert the key and turn to the ON position then remove the key and exit.

To unset, insert the key and turn to the OFF position.

Biased

To set the system with a biased keyswitch, insert the key and turn it then return the key to the original position, remove the key and exit.

To unset, repeat this operation.

Page 7

User Manual

GT 600 601

Unsetting The System

1)Enter the premises via the authorised entry route (the broken entry tone will sound).

Proceed to the keypad.

2)At the keypad enter a valid code, the display will show:-

3)The system is now unset.

01 JAN 18 : 58 : 01

Note: If an Area Code has been entered, only the area associated with that code will be unset.

Note: If a Cleaner Code has been entered, only the cleaner area will be unset.

Part Setting The System

(using Master & Main type codes)

1)With the display showing:-

2)Enter a Master or Main type code, the display will show for example:-

3)Press 1, 2 or 3 (for Part 1, 2 or 3), the display will show for example:-

01 JAN 18 : 58 : 01

Do you want to . .

Set the System ?

 

 

 

 

 

EXIT !

1

 

 

Part 1

15

 

 

 

 

 

 

 

 

 

Note: If a Global code (Master or Main) has been used, all areas that are being set will be Part 1 set.

Note: If an Area Main code has been used only Part 1 set for that associated area will occur.

Note: Your installation company will have informed you what zones are being removed (omitted) for the Part Set you are using. Refer to the System Attributes section for what zones have been programmed as Part Set zones.

Page 8

GT 600 601

User Manual

4)The exit tone may or may not be heard depending on the system settings.

5)Exit the premises or retire to an unprotected part of the system. At the end of the exit time either the exit sounder will stop or a single beep will be emitted (depending on system settings).

Part Setting System

(using Area 1, 2 or 3 codes, Area codes 4 - 7, 601 only)

1)With the display showing:-

2)Enter an Area Code (1, 2 or 3), the exit tone will sound and the display

will show for example:-

01 JAN 18 : 58 : 01

EXIT ! 1

 

All Zones ON

15

3)Press NO then 1, 2 or 3 (4 - 7, 601) (for the Part Set you require), the display will show for example:-

4)The exit sounders may or may not be silent, this will depend on the system settings.

5)Exit the premises or retire to an unprotected part of the system. At the end of the exit time either the exit sounder will stop or a single beep will be emitted (depending on system settings).

 

 

 

 

 

EXIT !

1

 

 

Part 1

20

 

 

 

 

 

 

 

 

 

Quick Part Setting System

If required there is a quick method to Part Set the system regardless of the level of code being used (except Control Level). To Part 1 Set the system Enter YES, YES CODE. The system will now start to Part 1 Set.

Page 9

User Manual

GT 600 601

Area Setting

(using Master or global Main codes)

Areas will need to have been set up by the installation company.

1)With the display showing:-

2)Enter a Master or global Main code, the display will show for example:-

3)Press YES to start setting the system, the exit tone will sound and the display will show:-

4)To turn Area 1 Off press YES, 1 and / or

To turn Area 2 Off press YES, 2 and / or

To turn Area 3 Off press YES, 3 and / or

To turn the Cleaner Area Off press YES, 0

As areas are turned off they will be removed from the display.

5)Exit the premises or retire to an un-protected area (as detectors are violated the continuous exit tone will change).

01 JAN 18 : 58 : 01

Do you want to . . SET the System ?

EXIT ! 1 2 3 C

 

All Zones ON

30

Note: Areas must first be programmed by the installation company before they will appear on the display.

Area Setting (using Area codes)

Area codes are only effective to their own area with the exception of the cleaner area. This may be turned off by an area code (only if all areas are in the unset condition).

Page 10

GT 600 601

User Manual

Removing Zones

(Master & Main codes only)

If programmed by the installation company individual zones may be removed, this may only be done by a Master or Main level of code. If a zone has not been programmed as ‘Remove’ an error message will be displayed when trying to remove it. It should be noted that if an Area Main code is being used, only zones associated with that area may be removed.

1)With the display showing:-

2)Enter a Master or Main level code, the display will show:-

3)Press NO, the display will show:-

4)Press YES, the display will show:-

5)Enter the zone number you wish to remove followed by YES (pressing NO will 'un-remove' a zone), the display will show:-

6)Repeat step 5 until you have removed all the required zones.

7)Press 0 to escape, the display will show:-

8)Press YES, the continuous exit tone will sound.

9)Exit the premises via the authorised

exit route ( the exit tone will change as detectors are violated). When the premises are secure listen that the exit tone returns to the continuous

tone. Wait until the exit tone finishes before leaving.

01 JAN 18 : 58 : 01

Do you want to . . SET the System ?

Do you want to . . REMOVE Zones ?

Enter Zone No. - - then + YES or - NO

Enter Zone No. - - then + YES or - NO

Do you want to . . SET the System ?

Note: Zone remove is only effective for the one set.

Page 11

User Manual

Testing The System (Master & Main codes only)

1)With the display showing:-

2)Enter a Master or Main level code, the display will show:-

3)Press NO, the display will show:-

4)Press NO, the display will show:-

5)Press YES, the display will show:-

GT 600 601

01 JAN 18 : 58 : 01

Do you want to . .

SET the System ?

Do you want to . .

REMOVE Zones ?

Do you want to . .

TEST the System ?

Test ALL Areas ?

6)Press YES to test the full system. or

NO.Then select the area you wish to test. Then press Yes.

The display will show:- for 3 seconds.

7)The display will then show:-

 

 

 

 

 

1=Status

4 = Strobe

 

 

6 = Sounder 9 = Bell

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

< All

Zones ok >

TESTING . . .

8)Pressing 1 will enter zone Status mode (All zones will show on the display and will be deleted as each zone is triggered). Press 0 to escape. Pressing 6 will silence the internal sounder,

Pressing 4 will toggle the Strobe On/Off, Pressing 9 will toggle the Bell On/Off

Page 12

GT 600 601

9)Whilst in Test mode any zones violated will sound the internal sounder (if it has not been silenced) and show on the display.

10)When you have finished testing the

system press 0 twice, the display will show:-

User Manual

01 JAN 18 : 58 : 01

Viewing The Event Log (Master code only)

1)With the display showing:-

2)Enter a Master Code, the display will show, for example:-

3)Press NO three times, the display will show:-

4)Press YES, the display will show, for example:-

01 JAN 18 : 58 : 01

Do you want to . . SET the System ?

Do you want to . . View the LOG ?

Read Log

01 JAN 18 : 58 : 01

Page 13

User Manual

5)This is the most recent event in the log. Whilst viewing the Log,

Pressing NO will move back to the previous event. Pressing YES will move forward to the next event.

Pressing 7 will take you to back to the last event of the previous day.

Pressing 9 will take you forward to the first event of the next day.

Whilst viewing a zone descriptor pressing 5 will show the zone number

6)When you have finished viewing the Log press 0 twice the display will show:-

GT 600 601

01 JAN 18 : 58 : 01

Changing The Chime Status (Master code only)

The Chime zones will have previously been programmed by the installation company. A Master level code may change the status of the Chime between On and Off. To do so proceed as follows:-

1) With the display showing:-

01 JAN 18 : 58 : 01

2)Enter a Master Code, the display will show for example:-

3)Press NO four times, the display will show:-

Do you want to . . SET the System ?

Do you want to . . Change Chime ?

Page 14

GT 600 601

4)Press YES the display will show for example:-

Or:-

5)Press NO to change the status of the Chime, then press YES, the display will show:-

6)Press 0 to escape, the display will show:-

User Manual

Chime is Off ok ?

Chime is On ok ?

Do you want to . .

Change Chime ?

01 JAN 18 : 58 : 01

Page 15

User Manual

GT 600 601

Programming & Deleting User Codes (Master code only)

You will be advised by your installation company on the code length required. Under no circumstances should the actual user code be written down.

If your installation company has given you keyswitches for the operation of your system the last five user codes may have been reserved for use by these keyswitches.

If your engineer has indicated that some of the user numbers on your system have been reserved you should not use them whilst programming user codes. If you do so your system may be adversely affected.

1)With the display showing:-

2)Enter a Master Code, the display will show:-

3)Press NO five times, the display will show:-

4)Press YES, the display will show:-

5)Enter the user number that you

wish to program followed by YES, the display will show:-

If you need to see allocated user numbers, press NO then keep pressing YES to view used or spare numbers. If spare, press NO.

6)Either Enter the User Code you require followed by YES

(If you wish to Delete a Code enter six Zeros followed by YES)

Or

Present your G-Tag to the Reader The display will show:-

01 JAN 18 : 58 : 01

Do you want to . .

SET the System ?

Do you want to . .

Prog. USER CODES ?

 

 

 

 

 

Enter User No.

- -

 

 

+YES or NO: View

 

 

 

 

 

 

 

 

 

 

Now Enter Code . .

- - - - - - Then YES

Code Type

 

= Master

ok ?

Page 16