External Wireless
Sounder
WL S50
Installation and Programming Instructions
2 |
Wireless Sounder Instructions |
Table of Contents |
|
Introduction........................................................................................................... |
4 |
Operational Functions.......................................................................................... |
4 |
Alarm / Tamper Indication ................................................................................... |
4 |
Low Battery Indication......................................................................................... |
4 |
Supervision ......................................................................................................... |
4 |
Pre Alarm Indication............................................................................................ |
4 |
Sounder Self Testing........................................................................................... |
4 |
LED display......................................................................................................... |
4 |
Mounting the Sounder.......................................................................................... |
5 |
Programming the sounder................................................................................... |
6 |
Step 1: Sounder/Receiver Communication Set up.............................................. |
6 |
Step 2: Setting the Sounder Parameters............................................................. |
7 |
Strobe Control ............................................................................................... |
7 |
Strobe Blink................................................................................................... |
7 |
Strobe Arm Squawk ...................................................................................... |
7 |
Adjusting the Volume .................................................................................... |
7 |
Muting Tamper .............................................................................................. |
7 |
Setting Supervision Time .............................................................................. |
8 |
Pre Alarm indication ...................................................................................... |
8 |
Step 3: Testing the Sounder ............................................................................... |
8 |
Communication Test ..................................................................................... |
8 |
Diagnostics.................................................................................................... |
8 |
Replacing Batteries .............................................................................................. |
9 |
Technical Information........................................................................................... |
9 |
Electrical ............................................................................................................. |
9 |
Wireless .............................................................................................................. |
9 |
Environment........................................................................................................ |
9 |
Wireless Sounder Instructions |
3 |
Introduction
RISCO Group's two-way External Wireless Sounder is designed to extend the signaling capabilities of the RISCO Group WisDom and Agility wireless systems, within the protected area. The wireless sounder offers an easy and flexible solution for quick installation. The sounder is powered with its own batteries and communicates wirelessly with the security panel using 868MHz frequency band. Up to 3 wireless sounders can be assigned to a system.
Operational Functions
Alarm / Tamper Indication
Upon an alarm condition, the sounder will be activated for a period of time defined by the system (Bell Time Out parameter).
The maximum time that the sound will be activated is 5 minutes.
Low Battery Indication
Upon a low battery condition a fault indication is sent to the panel. There are 2 types of low battery indications:
ÊRadio low battery
ÊSpeaker low battery
Supervision
Each sounder can be defined to be supervised by the panel. The system generates a local fault signal identifying the sounder whose signal is not received during a predefined time, followed by a report to the Alarm Receiving Center (if defined).
Pre Alarm Indication
When an entry time starts, the system transmits a pre-alarm signal to the sounder. If the system is unset before the entry delay time expires, a cancellation signal is sent to the sounder.
If the sounder does not receive a cancellation signal within the entry delay time, the sounder will be activated.
Sounder Self Testing
Once placing all batteries in the battery holders or pressing on the reset switch located on the PCB (with the tamper switch open), the sounder performs a functional self test indicated by a strobe flash squawk sound.
LED display
The wireless sounder has 2 LEDs located on the PCB. These LEDs are enabled when the tamper is open and 10 minutes after the tamper is closed. Red: Indicates transmission
Yellow: Indicates a low battery
Red and Yellow (3 seconds): Confirms successful learning