WL T6S
Wireless
Shock Detector
Installation
Instructions
United Kingdom
Tel: +44-161-655-5500 technical@riscogroup.co.uk
USA
Tel: +1-631-719-4400 support-usa@riscogroup.com
Italy
Tel: +39-02-66590054 assistenza@riscogroup.it
Spain
Tel: +34-91-490-2133 support-es@riscogroup.com
France
Tel: +33-164-73-28-50 support-fr@riscogroup.com
Belgium
Tel: +32-2522-7622 support-be@riscogroup.com
Brazil
Tel: +55-3661-8767 support-br@riscogroup.com
China
Tel: +86-21-52-39-0066 support-cn@riscogroup.com
Poland
Tel: +48-22-500-28-40 support-pl@riscogroup.com
Israel
Tel: +972-3-963-7777 support@riscogroup.com
RISCO Group Limited Warranty
RISCO Group and its subsidiaries and affiliates ("Seller") warrants its products to be free from defects in materials and workmanship under normal use for 24 months from the date of production. Because Seller does not install or connect the product and because the product may be used in conjunction with products not manufactured by the Seller, Seller cannot guarantee the performance of the security system which uses this product. Seller's obligation and liability under this warranty is expressly limited to repairing and replacing, at Seller's option, within a reasonable time after the date of delivery, any product not meeting the specifications. Seller makes no other warranty, expressed or implied, and makes no warranty of merchantability or of fitness for any particular purpose.
In no case shall seller be liable for any consequential or incidental damages for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever.
Seller's obligation under this warranty shall not include any transportation charges or costs of installation or any liability for direct, indirect, or consequential damages or delay.
Seller does not represent that its product may not be compromised or circumvented; that the product will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product will in all cases provide adequate warning or protection.
Buyer understands that a properly installed and maintained alarm may only reduce the risk of burglary, robbery or fire without warning, but is not insurance or a guaranty that such event will not occur or that there will be no personal injury or property loss as a result thereof.
Consequently seller shall have no liability for any personal injury, property damage or loss based on a claim that the product fails to give warning. However, if seller is held liable, whether directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or origin, seller's maximum liability shall not exceed the purchase price of the product, which shall be complete and exclusive remedy against seller. No employee or representative of Seller is authorized to change this warranty in any way or grant any other warranty.
NOTE: This product should be tested at least once a week.
FCC NOTE (for 433MHz versions only):
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
a)Reorient or relocate the receiving antenna.
b)Increase the separation between the equipment and receiver.
c)Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
d)Consult the dealer or an experienced radio/TV technician.
FCC Warning
The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user's authority to operate the equipment.
FCC ID: JE4RWT71X433
Fig. 1
SENSORPIEZO |
ON |
|
|
|
LED |
+ |
SW1 |
|
|
1 |
2 |
3 |
4 |
5 |
6 |
|
|
|
|
DIPSWITCH |
|
|
|
|||
|
|
|
|
D |
|
|
|
|
MAX MIN |
x |
SW2 |
BATTERY |
|
|
|
- |
RTTE Compliance Statement |
|
|
© |
|
|
|
|
Hereby, RISCO Group declares that this equipment is in compliance |
|
ANTENNA |
RISCO |
with the essential requirements and other relevant provisions of Directive |
|
||
1999/5/EC. |
|
|
|
For the CE Declaration of Conformity please refer to our website: |
|
|
|
www.riscogroup.com. |
|
|
|
|
|
|
|
© RISCO Group 08/14 |
5IN1341 D |
|
GENERAL DESCRIPTION
The WL T6S is a Shock detector intended for internal use that provides reliable 24-hour perimeter protection.
The detector employs an advanced digital microprocessor to analyze the vibration signal received from the piezo electric sensor.
This detector operates in conjunction with RISCO's programmable receivers and is powered by a standard 3- volt lithium battery.
MAIN FEATURES
•Digital Microprocessor with Intelligent Digital Signal Processing
•Tri-color LED enables accurate and reliable calibration, with “over-sensitive” and “under-sensitive” indications
•Gross attack detections
•Encapsulated bi-morph piezo electric sensor
•Dual stage adjustment potentiometer
•Back & Cover tamper protection
•Operates up to 300m (1000 ft) range (LOS)
•Uses one of more than 16 million addresses codes
•Fully supervised
DIPSWITCHES
Dipswitch |
Description |
|
1 |
Used to enable or disable LED |
|
|
Dipswitch Position |
LED |
|
ON (Default) |
Enabled |
|
OFF |
Disabled |
2 |
Used to determine the sensitivity of the Shock detector |
|
|
Dipswitch Position |
Sensitivity |
|
ON (Default) |
High |
|
OFF |
Low |
|
NOTE: For fine tuning use the sensitivity trimmer. |
|
3 |
Used to determine the time between the transmitter |
|
|
supervision messages. |
|
|
Dipswitch Position |
Supervision Time |
|
ON |
65 minutes |
|
OFF (Default) |
15 minutes |
4 |
Not used |
|
5 |
Not used |
|
6 |
Used to determine the detector RF power |
|
|
Dipswitch Position |
RF Power Transmission |
|
ON |
Low |
|
OFF (Default) |
High |
LED INDICATION
After each detection, the LED turns ON momentarily.
On Low Battery condition, the LED will blink during each transmission.
GREEN Indicates an alarm condition
RED • Under-Sensitive indication
•Tamper indication
•Write message
ORANGE Over-Sensitive indication
FRONT COVER REMOVAL
Remove the front cover as described in Figure 2.
TRANSMITTER/RECEIVER COMMUNICATION SET UP
The transmitter must identify itself to the system’s receiver by writing its coded messages into the receiver’s address memory. This is accomplished by performing the following steps:
a.Set the receiver to the Write Mode (follow the receiver’s instructions).
b.Remove the battery from the insulation material and reinsert it into the transmitter, paying attention to the polarity (see Fig. 3).
c.Send a Write message by pressing both tamper buttons for at least 3 seconds.
d.Set the receiver to the Normal mode.
e.Verify that the receiver has identified the detector by generating a tamper signal (by momentarily closing and opening both tampers).
NOTE: If for any reason it is necessary to re-send a write message, press both of the tamper buttons (back and cover) for at least 3 seconds.
INSTALLATION INSTRUCTIONS
Considerations for wireless communication
a.For best wireless communication, place the unit at the highest possible position.
b.Temporarily attach the unit to this point using two sided adhesive tape.
c.Generate an Alarm or Tamper signal and verify that the receiver has received the signal. If the signal is not detected, reposition the transmitter and try again.
Considerations for installation
1.Select the intended position for installation, ensuring the surface is clean and clear of any irregularities. Refer to Table 1 for details about detection ranges for the different surface types.
2.Set the detector’s sensitivity as follows, using the sensitivity trimmer:
i.With the unit set for normal operation, use a suitable instrument to bang or tap the protected area.
ii.If the sensitivity needs adjustment, use a screwdriver to adjust the trimmer (turn the trimmer control clockwise to increase sensitivity or counter-clockwise to reduce sensitivity).
iii.Repeat steps i and ii until the desired sensitivity level is achieved. If required, you can set Dipswitch 2 to OFF to reduce sensitivity range.
3.Close the front cover.
Table 1: Typical Detection Range
Surface |
Concrete |
Brick Wall |
Steel |
Glass |
Wood |
Plywood |
Radius |
1.5m (5ft) |
2.5m (8.2ft) |
3m (10ft) |
3.5m (11.5ft) |
3.5m (11.5ft) |
4m (13ft) |
The above values are typical and are subject to practical testing, which must be performed for each installation. In some environments, these values may differ from the values listed above.
FINAL MOUNTING
Separate the back part of the transmitter (Fig. 4), and mount all the parts in place (Fig. 5).
SPECIFICATIONS
ELECTRICAL
Battery Type: |
CR123 3V Lithium Battery |
Current Consumption: |
10µA standby |
Frequency: |
433.92 / 868.65 MHz |
Supervision Transmission: |
Every 15/65 minutes |
Modulation Type: |
ASK |
Battery Life: |
5 years depends on usage |
PHYSICAL |
|
Size: |
81x35x32mm (3.2x1.37x1.27in.) |
ENVIRONMENTAL |
|
RF immunity: |
According to EN-50130-4 |
Operating temperature: |
0°C to 55°C (32°F to 131°F) |
Storage temperature: |
-20°C to 60°C (-4°F to 140°F) |
Maximum humidity: |
95% non-condensing |
Specifications are subject to change without prior notice.
Should any questions arise please contact your supplier.
DESCRIPTION GENERALE
Le détecteur de Choc WL T6S est destiné à une utilisation intérieure qui offre une protection périmétrique fiable 24h/24. Grâce à son microprocesseur numérique de pointe, le détecteur analyse tout signal de vibration qui lui est envoyé par le capteur piézo-électrique.
Alimenté par une pile au lithium de 3V standard, il fonctionne en combinaison avec les récepteurs programmables de RISCO.
CARACTERISTIQUES PRINCIPALES
•Microprocesseur avec traitement intelligent du signal numérique
•Diode électroluminescente tricolore (LED) pour un calibrage précis et fiable, avec indications "d'excès" et "d'insuffisance" de sensibilité
•Détection d'attaques brutales
•Capteur piézo-électrique bimorphe intégré
•Potentiomètre à double réglage
•Autoprotection à l'arrachement et à l'ouverture
•Portée allant jusqu'à 300 m. (1000 ft.) (Champ libre)
•Utilise un code d'adresse parmis plus de 16 millions
•Durée de vie étendue de la pile
•Entièrement supervisé
DIPSWITCHES
Dipswitch |
Description |
|
|
|
|
1 |
Utilisé pour activer ou désactiver la LED |
|
|
Position du DIP |
LED |
|
ON (par défaut)) |
Activé |
|
OFF |
Désactivé |
2 |
Utilisé pour déterminer la sensibilité du détecteur de choc |
|
|
Position du DIP |
Sensibilité |
|
ON (par défaut) |
Elevée |
|
OFF |
Faible |
|
NOTE : Pour un réglage fin, utiliser le potentiomètre de |
|
|
sensibilité. |
|
3 |
Utilisé pour déterminer le délai entre l’envoie des messages |
|
|
de supervision du transmetteur. |
|
|
Position du DIP |
Délai de Supervision |
|
ON |
65 minutes |
|
|
|
|
OFF (par défaut) |
15 minutes |
4 |
Inutilisé |
|
5 |
Inutilisé |
|
6 |
Sert à déterminer la puissance de transmission RF. |
|
|
Position du DIP |
Transmission RF |
|
ON |
Faible |
|
OFF (par défaut) |
Elevée |
INDICATIONS LED
Après chaque détection, la diode LED s'allume momentanément. Lorsque la pile est faible (batterie faible) – la diode LED clignote à chaque transmission.
VERTE |
Indique une condition d'alarme |
|
ROUGE |
• |
Indique une insuffisance de sensibilité |
|
• |
Indication de sabotage |
|
• |
Message d'écriture |
ORANGE |
Indique un excès de sensibilité |
RETRAIT DU COUVERCLE FRONTAL
Enlever le couvercle comme décrit en figure 2.
PARAMETRAGE DE LA COMMUNICATION
TRANSMETTEUR/ RÉCEPTEUR
Le transmetteur doit s'identifier auprès du récepteur du système en inscrivant ses messages codés dans le registre d'adresses du récepteur. Cette opération s'accomplit en exécutant les étapes suivantes :
a.Réglez le récepteur en mode écriture (suivez pour cela les instructions correspondantes).
b.Retirez la pile de sa protection isolante et réinsérez-la dans le transmetteur en respectant la polarité indiquée (cf. fig. 3).
c.Envoyez un message d'écriture en appuyant sur les deux contacts d'autoprotection pendant au moins 3 secondes.
d.Réglez le récepteur en mode normal.
e.Vérifiez que détecteur a bien été identifié par le récepteur : pour cela, générez un signal d'autoprotection (en fermant et ouvrant
momentanément les deux AP).
REMARQUE : si pour une raison quelconque, il s'avère nécessaire de renvoyer un message d’écriture, il suffit pour cela d'appuyer simultanément sur les deux contacts d'autoprotection (arrière et couvercle) pendant au moins 3 secondes.
INSTRUCTIONS D'INSTALLATION
Considérations pour la communication sans fil
a.Pour une meilleure communication, placez l'appareil le plus haut possible.
b.Fixez provisoirement l'appareil en ce point en utilisant de l'adhésif double face.
c.Générer un signal d'alarme ou d'AP et vérifiez que le récepteur a bien reçu le signal. Si le signal d'alarme n'a pas été détecté, repositionnez le transmetteur et réessayez.
Considérations pour l’installation
1.Choisissez l'endroit souhaité pour l'installation, en vous assurant que la surface est bien propre et nette de toutes aspérités. Se reporter au tableau 1 pour consulter les portées de détection selon les différents types de surfaces.
2.Ajuster la sensibilité du détecteur comme suit, en vous servant du potentiomètre de sensibilité :
(i)L'appareil étant en mode de fonctionnement normal, feignez, à l'aide d'un instrument adapté, une intrusion (en cognant ou frappant) au sein de la zone protégée.
(ii)Si la sensibilité requiert un ajustement, ajustez le réglage à l'aide d'un tournevis (dans le sens des aiguilles d'une montre pour augmenter la sensibilité, et dans le sens inverse pour la réduire).
(iii)Renouvelez les étapes (i) et (ii) jusqu'à obtenir le niveau de sensibilité souhaité. Si nécessaire, vous pouvez mettre le Dipswitch 2 sur OFF pour réduire la sensibilité.
3.Fermez le couvercle frontal.
Tableau 1 : Portées typiques de détection
Surface |
Béton |
Mur de briques |
Acier |
Verre |
Bois |
Contreplaqué |
Rayon |
1,5 m |
2,5 m |
3m |
3,5 m |
3,5 m |
4m |
Les valeurs indiquées ci-dessus sont des valeurs typiques et doivent être soumises à un test pratique à réaliser à chaque installation. Dans certains environnements, ces valeurs peuvent être différentes de celles du tableau ci-dessus.
ASSEMBLAGE FINAL
Séparez la partie arrière de l’émetteur (Fig. 4), et montez toutes les pièces (Fig. 5).
SPECIFICATIONS
ELECTRIQUES
Type de batterie : |
pile lithium 3V CR123 |
Consommation électrique : |
10µA en veille |
Fréquence : |
433.92 / 868.65 MHz |
Transmission de supervision : |
toutes les 15 / 65 minutes |
Type de modulation : |
ASK |
Durée de vie de la pile : |
5 ans selon utilisation |
PHYSIQUES |
|
Dimensions : |
81 x 35 x 32 mm |
|
|
ENVIRONNEMENTALES |
|
Immunité RF : |
selon la norme EN-50130-4 |
|
|
Température de |
de 0°C à 55°C |
fonctionnement : |
|
Température de stockage : |
de -20°C à 60°C |
Humidité maximum : |
95% sans condensation |
|
|
Ces spécifications sont susceptibles d'être modifiées sans avis préalable. Si vous avez des questions, veuillez contacter votre fournisseur.