Pilz PNOZ mmc7p CC User Manual

PNOZ mmc7p CC
Operating Manual-1003066-EN-01
Configurable Control System PNOZmulti

Preface

This document is a translation of the original document.
All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received.
Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®, SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks of Pilz GmbH & Co. KG in some countries.
SD means Secure Digital
Content
Operating Manual PNOZ mmc7p CC 1003066-EN-01
Section 1 Introduction 4
1.1 Validity of documentation 4
1.2 Retaining the documentation 4
1.3 Definition of symbols 4
Section 2 Overview 5
2.1 Scope of supply 5
2.2 Unit features 5
2.3 Front view 6
Section 3 Safety 7
3.1 Intended use 7
3.2 System requirements 7
3.3 Safety regulations 8
3.3.1 Use of qualified personnel 8
3.3.2 Warranty and liability 8
3.3.3 Disposal 8
3.3.4 For your safety 8
Section 4 Function description 9
4.1 Functions 9
4.2 Input and output data 9
4.3 Block diagram 10
Section 5 Installation 11
5.1 General installation guidelines 11
5.2 Connect the base unit and expansion modules 11
5.3 Dimensions 11
Section 6 Commissioning 12
6.1 General wiring guidelines 12
6.2 Connecting the supply voltage 12
6.3 Interface assignment 13
6.4 Download modified project to the PNOZmulti safety system 13
6.5 Connection example 14
Section 7 Operation 15
7.1 Messages 15
Section 8 Technical Details 16
Section 9 Order reference 18
3

Introduction

Operating Manual PNOZ mmc7p CC 1003066-EN-01
1
1.1
1.2
1.3
Introduction

Validity of documentation

This documentation is valid for the product PNOZ mmc7p CC. It is valid until new documen­tation is published.
This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.

Retaining the documentation

This documentation is intended for instruction and should be retained for future reference.

Definition of symbols

Information that is particularly important is identified as follows:
DANGER!
This warning must be heeded! It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken.
WARNING!
This warning must be heeded! It warns of a hazardous situation that could lead to serious injury and death and indicates preventive measures that can be taken.
CAUTION!
This refers to a hazard that can lead to a less serious or minor injury plus material damage, and also provides information on preventive measures that can be taken.
NOTICE
This describes a situation in which the product or devices could be dam­aged and also provides information on preventive measures that can be tak­en. It also highlights areas within the text that are of particular importance.
INFORMATION
This gives advice on applications and provides information on special fea­tures.
4

Overview

Operating Manual PNOZ mmc7p CC 1003066-EN-01
2
2.1
2.2
Overview

Scope of supply

} Expansion module PNOZ mmc7p CC
} Jumper 779 260

Unit features

Using the product PNOZ mmc7p CC:
Expansion module for connection to a base unit from the configurable control system PNOZmulti Mini .
The product has the following features:
} Can be configured in the PNOZmulti Configurator
} Connection for CC-Link
} Station addresses from 1 ... 63, selected via rotary switch
} Station type: Remote Device
} Occupied stations: 2
} 24 virtual inputs and outputs on the control system PNOZmulti can be defined in the
PNOZmulti Configurator for communication with the fieldbus CC-Link . The number of inputs and outputs can be extended to 128. Please note that when the extended inputs and outputs 24 - 127 are used they have different properties (see document entitled "Communication Interfaces").
} Max. 1 PNOZ mmc7p CC can be connected to the base unit
} Plug-in connection terminals:
either spring-loaded terminal or screw terminal available as an accessory (see order reference)
} Please refer to the document "PNOZmulti System Expansion" for the PNOZmulti base
units that can be connected
5
Overview
Operating Manual PNOZ mmc7p CC 1003066-EN-01
2.3

Front view

Legend:
} X1: CC-Link interface
} 0 V, 24 V: Supply connections
} LEDs:
– Power
– Run
– L Err
6
Loading...
+ 13 hidden pages