This document is a translation of the original document.
All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made
for internal purposes.
Suggestions and comments for improving this documentation will be gratefully received.
Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®, SafetyEYE®,
SafetyNET p®, the spirit of safety® are registered and protected trademarks of
Pilz GmbH & Co. KG in some countries.
SD means Secure Digital.
Page 3
Contents
Contents
ContentsPage
Chapter 1 Introduction
1.1Validity of documentation1-1
1.1.1Retaining the documentation1-1
1.2Overview of documentation1-2
1.3Definition of symbols1-3
Chapter 2 Overview
2.1Unit structure2-1
2.1.1Scope of delivery2-1
2.1.2Unit features2-1
2.2Front view2-2
2.2.1Key2-2
Chapter 3 Safety
3.1Intended use3-1
3.1.1System requirements3-1
3.2Safety regulations3-2
3.2.1Use of qualified personnel3-2
3.2.2Warranty and liability3-2
3.2.3Disposal3-2
3.2.4For your safety3-3
Chapter 4 Function description
4.1Unit properties4-1
4.1.1Block diagram4-1
Chapter 5 Installation
5.1General installation guidelines5-1
5.1.1Dimensions5-1
5.2Connecting the base unit and expansion
modules
Chapter 6 Commissioning
6.1Wiring6-1
6.1.1General wiring guidelines6-1
6.1.2Interface configuration6-1
6.2Preparing for operation6-2
6.2.1Download modified project to the PNOZmulti safety system
1.3Definition of symbols1300Definition of symbols1-Einfhrung Zeichen
Information that is particularly important is identified as follows:
DANGER!
This warning must be heeded! It warns of a hazardous situation
that poses an immediate threat of serious injury and death and
indicates preventive measures that can be taken.
WARNING!
This warning must be heeded! It warns of a hazardous situation
that could lead to serious injury and death and indicates preventive measures that can be taken.
CAUTION!
This refers to a hazard that can lead to a less serious or minor
injury plus material damage, and also provides information on
preventive measures that can be taken.
NOTICE
This describes a situation in which the product or devices could
be damaged and also provides information on preventive measures that can be taken.
INFORMATION
This gives advice on applications and provides information on
special features, as well as highlighting areas within the text that
are of particular importance.
Communication module for connection to a base unit PNOZmulti Mini.
The product has the following features:
` Can be configured in the PNOZmulti Configurator
` 1 serial interface RS 232
` Status indicator for supply voltage
` Max. 1 communication module can be connected to the left of the
base unit PNOZmulti Mini
` Plug-in connection terminals (either cage clamp terminals or screw
Bestimmung/Gertebeschreibung_multi_ nicht sicherheitsgerichtete Funkt
The expansion module PNOZ mmc2p is used for communication of the
configurable safety relay PNOZmulti Mini via a serial interface RS 232.
The expansion module may only be connected to a base unit PNOZmulti
Mini from the modular safety system PNOZmulti.
The modular safety system PNOZmulti is used for the safety-related interruption of safety circuits and is designed for use on:
` E-STOP equipment
` Safety circuits in accordance with VDE 0113 Part 1 and EN 60204-1
Bestimmung/Gertebeschreibung_Ausschluss
3.1.1System requirements
System requirements3-Systemvoraussetzungen PNOZ mmc2p ser
The expansion module may not be used for safety-related functions.
Intended use includes making the electrical installation EMC-compliant.
The product is designed for use in an industrial environment. It is not
suitable for use in a domestic environment, as this can lead to interference.
The following is deemed improper use in particular:
` Any component, technical or electrical modification to the product
` Use of the product outside the areas described in this manual
` Use of the product outside the technical details (see chapter entitled
“Technical Details”)
` PNOZmulti Configurator: From Version 7.1.0
` Base unit PNOZ mm0.1p: From Version 1.0
The products may only be assembled, installed, programmed, commissioned, operated, maintained and decommissioned by competent persons.
A competent person is someone who, because of their training, experience and current professional activity, has the specialist knowledge required to test, assess and operate the work equipment, devices,
systems, plant and machinery in accordance with the general standards
and guidelines for safety technology.
It is the company's responsibility only to employ personnel who:
` Are familiar with the basic regulations concerning health and safety /
accident prevention
` Have read and understood the safety guidelines given in this descrip-
tion
` Have a good knowledge of the generic and specialist standards ap-
plicable to the specific application.
3.2.2Warranty and liability
Warranty and liability3-Sich Gewhrleistung
3.2.3Disposal
Disposal3-Si ch Entsorgung
All claims to warranty and liability will be rendered invalid if:
` The product was used contrary to the purpose for which it is intended
` Damage can be attributed to not having followed the guidelines in the
manual
` Operating personnel are not suitably qualified
` Any type of modification has been made (e.g. exchanging compo-
nents on the PCB boards, soldering work etc.).
` In safety-related applications, please comply with the mission time t
M
in the safety-related characteristic data.
` When decommissioning, please comply with local regulations regard-
ing the disposal of electronic devices (e.g. Electrical and Electronic
Equipment Act).
The unit meets all necessary conditions for safe operation. However,
you should always ensure that the following safety requirements are
met:
` This operating manual only describes the basic functions of the unit.
Information on the advanced functions can be found in the online help
for the PNOZmulti Configurator and in the PNOZmulti technical catalogue. Only use these functions after you have read and understood
the documentation. All necessary documentation can be found on the
PNOZmulti Configurator CD.
` Do not open the housing or make any unauthorised modifications.
` Please make sure you shut down the supply voltage when performing
` The unit should be installed in a control cabinet with a protection type
of at least IP54.
` Use the notch on the rear of the unit to attach it to a mounting rail.
` In environments exposed to heavy vibration or when installing on a
vertical mounting rail (35 mm), the unit should be secured using a fixing element (e.g. retaining bracket or end angle).
` Push the unit upwards or downwards before lifting it from the mount-
ing rail.
` The ambient temperature of the PNOZmulti units in the control cabi-
net must not exceed the figure stated in the technical details, otherwise air conditioning will be required.
CAUTION!
Damage due to electrostatic discharge!
Electrostatic discharge can damage components. Ensure
against discharge before touching the product, e.g. by touching
an earthed, conductive surface or by wearing an earthed armband.
6.2Preparing for operation6200Preparing for operation6-Betriebsbereitschaft herstellen - Schnittstelle wählen- seriell
The serial interface RS 232 is activated and detected depending on the
USB interface on the base unit:
` USB interface on the base unit not connected
In this case, the serial interface RS 232 will be detected and activated
by the base unit as soon as the communication module has been
connected to the base unit.
` USB interface on the base unit connected
If the USB interface on the base unit is already connected, the "External" interface will first need to be selected on the base unit display
to enable the serial interface RS 232 on the base unit to be detected
and activated (see operating manual for the base unit for details of
the setting).
6.2.1Download modified project to the PNOZmulti safety system
Download modified project to the PNOZmulti safety system6-Verdrahtung_multi_Modul_Betr_geaend_Projekt_BA
As soon as an additional expansion module has been connected to the
system, the project must be amended using the PNOZmulti Configurator. Proceed as described in the operating instructions for the base unit.
NOTICE
For the commissioning and after every program change, you
must check whether the safety devices are functioning correctly.
When the supply voltage is switched on, the PNOZmulti safety system
copies the configuration from the chip card.
The LEDs "POWER","DIAG", "FAULT", "IFAULT" and "OFAULT" light up
Betrieb_Meldungen_Kommu nikationsmodul_BA
7.1.1Display elements for device diagnostics
Display elements for device diagnostics 7-Anzeige Legende 3x
on the base unit.
The safety system PNOZmulti is ready for operation when the "POWER"
and "RUN" LEDs on the base unit and the "POWER" LED on the
PNOZ mmc2p are lit continuously.
EMCEN 55011: class A, EN 61000-6-2, EN 61000-6-4
Vibration to EN 60068-2-6
Frequency10 - 55 Hz
Amplitude0.35 mm
Climatic suitabilityEN 60068-2-14, EN 60068-2-1, EN 60068-2-2,
EN 60068-2-30, EN 60068-2-78
Airgap creepage in accordance withEN 61131-2
Ambient temperature0 - 60 °C
Storage temperature-25 - 70 °C
Mechanical data
Protection type
Mounting (e.g. cabinet)IP54
HousingIP20
TerminalsIP 20
DIN rail
Top hat rail35 x 7.5 EN 50022
Recess width27 mm
Maximum cable runs
per input22.0 m
Housing material
HousingPC
FrontPC
Cross section of external conductors with screw terminals
1 core flexible0.50 - 1.50 mm² , 22 - 14 AWG
2 core, same cross section, flexible:
Rigid single-core, flexible multicore or multi-core with
crimp connector
Torque setting with screw terminals0.50 Nm
Spring-loaded terminals: Terminal points per connection2
Stripping length9 mm
Dimensions
Height100.0 mm
Width22.5 mm
Depth120.0 mm
Weight85 g
of Pilz GmbH & Co. KG in some countries. We would point out that product features may vary from the details stated in this document, depending on the status at the time of publication and the scope
of the equipment. We accept no responsibility for the validity, accuracy and entirety of the text and graphics presented in this information. Please contact our Technical Support if you have any questions.
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.